Designed to improve manufacturing process control in a printing plant, Carrier's invention controlled not only temperature but also humidity. Carrier used his knowledge of the heating of objects with steam and reversed the process. Instead of sending air through hot coils, he sent it through cold coils (filled with cold water). The air was cooled, and thereby the amount of moisture in the air could be controlled, which in turn made the humidity in the room controllable. The controlled temperature and humidity helped maintain consistent paper dimensions and ink alignment. Later, Carrier's technology was applied to increase productivity in the workplace, and The Carrier Air Conditioning Company of America was formed to meet rising demand. Over time, air conditioning came to be used to improve comfort in homes and automobiles as well. Residential sales expanded dramatically in the 1950s.[citation needed]
Talk to your HVAC repair contractor about options to make HVAC repair costs more affordable. Many contractors offer financing options to assist customers in this very position, as well as payment plans. HVAC companies know HVAC repair costs can come as quite a shock in some scenarios, and want to help you get the repairs your system needs to preserve your comfort and safety.
Home | About | Careers | Maintenance Plans | Services | Repairs & Maintenance | Residential Replacement | New Construction | Products | Furnaces | Air Conditioners | Heat Pumps | Ductless Systems | Thermostats | Air Cleaners | Humidifiers | Resources | Special Savings | Testimonials | Blog | Gallery | Contact | Site Map Charlotte Heating & Cooling | Dewitt Heating & Cooling | Dimondale Heating & Cooling | East Lansing Heating & Cooling | Eaton Rapids Heating & Cooling | Haslett Heating & Cooling | Holt Heating & Cooling | Lansing Heating & Cooling | Mason Heating & Cooling | Mulliken Heating & Cooling | Okemos Heating & Cooling | Portland Heating & Cooling | Webberville Heating & Cooling | Williamston Heating & Cooling

7) Schedule an annual tune-up with an HVAC professional. A trained HVAC technician can detect most problems before they become major ones. With a cost of around $100 for a routine maintenance call, the benefits will likely outweigh the costs by a considerable margin. A typical tune-up will include various tests to ensure your unit’s internal parts are functioning correctly, as well as a filter check, and a refrigerant charge if needed. Your technician will likely also clear the drain, and clean your unit thoroughly inside and out.


Dichlorodifluoromethane (R-12) was the most common blend used in automobiles in the U.S. until 1994, when most designs changed to R-134A due to the ozone-depleting potential of R-12. R-11 and R-12 are no longer manufactured in the U.S. for this type of application, so the only source for air-conditioning repair purposes is the cleaned and purified gas recovered from other air conditioner systems. Several non-ozone-depleting refrigerants have been developed as alternatives, including R-410A. It was first commercially used by Carrier Corp. under the brand name Puron.[citation needed]

We want to compliment your fine sales and installation team. They are outstanding. Carlos, your sales rep., was highly informative. We reviewed our needs and we ultimately chose the Trane XV-18 variable speed system. Carlos did not try to up sell us with things that we did not need but he did help us choose the correct upgraded filter and UV light that we wanted. We told Carlos that our research indicated that the quality of the installation of the unit was at least as important as the unit itself, and Carlos agreed. Carlos pointed out that new proper sized duct work and copper wiring would be required for a correct installation, and that we needed to add two more returns. We asked if more returns were needed and Carlos said that would not be cost effective. That was great to hear. Carlos assured us that the installation team of Willie and Gary, both lead installers, would be used. They were both superb. They came on time and worked for 12 and 1/2 hours. It was a 93 degree day so the heat in the attic was intense. We kept telling them to take a break but they continued to work up there in what must have been 130+ temperatures. They were amazing! They were neat and cleaned up any mess they made. They patiently answered all of our many questions and gave us helpful tips. They were truly professional in all respects. We also note that Stacy, Angie and Karen of your office staff were each courteous, accommodating and efficient. They helped things to go smoothly. Carlos, Gary, Stacy, Angie, Willie and Karen are each great assets to your company. We would be comfortable recommending that team of people to anyone! Ken and Kathy Luban
Energy efficiency can be improved even more in central heating systems by introducing zoned heating. This allows a more granular application of heat, similar to non-central heating systems. Zones are controlled by multiple thermostats. In water heating systems the thermostats control zone valves, and in forced air systems they control zone dampers inside the vents which selectively block the flow of air. In this case, the control system is very critical to maintaining a proper temperature.
Replacing a capacitor is easy. Just take a photo of the wires before disconnecting anything (you may need a reference later on). Then discharge the stored energy in the old capacitor (Photo 4). Use needle-nose pliers to pluck one wire at a time from the old capacitor and snap it onto the corresponding tab of the new capacitor. The female crimp connectors should snap tightly onto the capacitor tabs. Wiggle each connector to see if it’s tight. If it’s not, remove the connector and bend the rounded edges of it so it makes a tighter fit on the tab. When you’ve swapped all the wires, secure the new capacitor (Photo 5).
Air changes per hour Bake-out Building envelope Convection Dilution Domestic energy consumption Enthalpy Fluid dynamics Gas compressor Heat pump and refrigeration cycle Heat transfer Humidity Infiltration Latent heat Noise control Outgassing Particulates Psychrometrics Sensible heat Stack effect Thermal comfort Thermal destratification Thermal mass Thermodynamics Vapour pressure of water
During the colder months of the year, the comfort of your home depends on the proper working function of your heating system. When your furnace breaks down or stops working properly, reach out to the heating experts at Horizon Services! We have nearly 30 years of experience providing reliable furnace repairs for homeowners throughout Delaware, Southern New Jersey, Southeastern Pennsylvania, and Northeastern Maryland. Our technicians are able to repair just about any type of home furnace using cutting-edge techniques and state-of-the-art tools. We can accurately diagnose the root of the issue and quickly get to work making the necessary repairs. We even offer same day service at no additional cost!
1) Change your filter. The simplest and most effective way to keep your AC running smoothly is changing your filter once a month. By regularly changing your filter, you reduce a lot of the burden on your system. A dirty or clogged filter makes your air conditioner work much harder than does a clean filter. Changing your filters regularly is easy on your budget and easy on your system as well. It will lower your utility bill and extend the life of your AC.
Before opening the electrical cover on the A/C unit, be sure to shut off all power to the compressor unit and the indoor furnace or air handler, and verify that it is off. Note that this may mean shutting off a circuit breaker that serves the furnace and air handler, and then, near the compressor, pulling out the disconnect block (or shutting off the 220-volt power) to the outdoor compressor.
×