It’s important to keep your furnace receives regular maintenance to ensure that it’s working properly and efficiently. Routine maintenance can also extend the life of your heating system by several years. Ask about our annual maintenance agreements that cover your plumbing, heating, and cooling systems and save you money. A furnace that has been neglected may be working too hard, which can result in inconsistent air temperatures in your Minneapolis area home. Learn more about the importance of routine maintenance on your HVAC system.
As touched on by their name, heat pumps function by transferring heat energy indoors during the winter and outdoors from your home during the summer. They're often attached to air conditioning units, using the surrounding air to transfer energy. However, geothermal heat pumps and water source heat pumps are also available. The cost to repair a heat pump, again, depends on the specific problem. Replacing a faulty thermostat may cost up to $300 including labor, while a worn or damaged defrost control board can set you back up to $600. For more details on your potential repair costs using this heating source, visit our heat pump repair cost guide.
If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.
The most recognized standards for HVAC design are based on ASHRAE data. The most general of four volumes of the ASHRAE Handbook is Fundamentals; it includes heating and cooling calculations. Each volume of the ASHRAE Handbook is updated every four years. The design professional must consult ASHRAE data for the standards of design and care as the typical building codes provide little to no information on HVAC design practices; codes such as the UMC and IMC do include much detail on installation requirements, however. Other useful reference materials include items from SMACNA, ACGIH, and technical trade journals.

The main purpose of your furnace filter is to ensure that none of the additional materials your fans pull back into the unit - such as hair and dust - actually damage the furnace or its parts. In the process, it also improves air quality in your home. Some annual inspections will include changing and cleaning this part of the unit. That said, you can also clean or change your furnace filteryourself. Costs for new filters range based on brand, but tend to be around $30.


At times, malfunctions strike without warning.  These problems rarely stick to regular business hours.  When your comfort, safety, and well-being is at stake, don’t wait for Monday morning.  The service team from Ferran Services is available 24/7 to provide the prompt and dependable assistance you require.  Fully-stocked service trucks and extensively trained technicians allow us to handle the majority of repair requirements in a single visit.  We work on all makes and models, and our technicians do not rely on commission.  We never take advantage of your desperate situation, never sell you a product or service you don’t need, and always keep you informed.  By relying on Factory Authorized Parts, we restore system efficiency, sound levels, and longevity.
It’s important to keep your furnace receives regular maintenance to ensure that it’s working properly and efficiently. Routine maintenance can also extend the life of your heating system by several years. Ask about our annual maintenance agreements that cover your plumbing, heating, and cooling systems and save you money. A furnace that has been neglected may be working too hard, which can result in inconsistent air temperatures in your Minneapolis area home. Learn more about the importance of routine maintenance on your HVAC system. 

Most central air conditioners are connected to a home's forced-air distribution system. Thus, the same motor, blower, and ductwork used for heating are used to distribute cool air from the air conditioning system. When a central air conditioner is operating, hot air inside the house flows to the furnace through the return-air duct. The hot air is moved by the blower across the cooled evaporator coil in the plenum and is then delivered through ducts to cool the house. When the air conditioner works but the house doesn't cool, the problem is probably in the distribution system.
As a Carrier Factory Authorized Dealer, M and M, Heating & Cooling, Plumbing & Electrical is qualified to properly size and install the most technologically advanced and well-regarded heating, cooling, and air quality products on the market today. Our team is NATE-certified, factory trained, EPA certified, and regularly updated, ensuring the right solution to any challenge.

Whether you are in need of new installation, system replacement, seasonal maintenance, or prompt repair, M and M, Heating & Cooling, Plumbing & Electrical lives up to your highest expectations for quality, pricing, reliability, and quick turnaround on all projects.  And our commitment isn’t limited to regular business hours.  We’re always available when you need us, providing 24 hour Emergency Service across Longmont, Dacono, Frederick, Firestone, Mead, Erie & Johnstown, CO.  Trust the #1 Rated and Certified – A/C, Heating, and Plumbing Experts.

AC air handler squealing or grinding noises. Though most air handlers have direct-drive motors, some older units may be belt-driven. Squealing sounds from a belt-drive air handler generally occur when the belt that connects the motor to the blower slips. In most cases, the belt is improperly aligned or worn and needs replacement. Follow the instructions above under Air Conditioner Not Blowing Air and refer to your owner’s manual.
If the condenser coils are clogged, the compressor can overheat and shut down. You’ll experience intermittent periods of minimal cooling, followed by no cooling. Even if you’re “sure” the condenser coils are clean, clean them again. Turn off the power. Flip the air conditioning service and furnace circuit breakers in your main electrical panel to the “Off” position. Next, turn off the power switch right at the furnace or air handler. Then yank the disconnect block (Photo 1) and clean the condenser coils (Photo 2). If the air conditioning service still doesn’t work properly after you’ve cleaned the condenser coils, installed a new filter and opened all the supply vents, proceed with the following repairs.
Air conditioners can create a lot of water because they remove moisture from the air. To get rid of this, they have a [usually plastic] drain pipe that comes out of the side of the air handler. Over time, algae can block this pipe and, when it does, the AC won’t work. In fact, some condensate drains have a float switch that won’t let the AC run if water backs-up. Water can also puddle around the unit or flood the area. To deal with condensate problems, please see Air Conditioner Leaks Water, below.
In 1758, Benjamin Franklin and John Hadley, a chemistry professor at Cambridge University, conducted an experiment to explore the principle of evaporation as a means to rapidly cool an object. Franklin and Hadley confirmed that evaporation of highly volatile liquids (such as alcohol and ether) could be used to drive down the temperature of an object past the freezing point of water. They conducted their experiment with the bulb of a mercury thermometer as their object and with a bellows used to speed up the evaporation. They lowered the temperature of the thermometer bulb down to −14 °C (7 °F) while the ambient temperature was 18 °C (64 °F). Franklin noted that, soon after they passed the freezing point of water 0 °C (32 °F), a thin film of ice formed on the surface of the thermometer's bulb and that the ice mass was about 6 mm (1⁄4 in) thick when they stopped the experiment upon reaching −14 °C (7 °F). Franklin concluded: "From this experiment one may see the possibility of freezing a man to death on a warm summer's day."[9]
×