Handling the service needs of homeowners throughout Orlando, FL, Volusia, FL since 1910, we’ve built our business on a foundation of well-earned trust.  We uphold an A+ rating from the Better Business Bureau.  As a Carrier Factory Authorized Dealer, Ferran Services has been further distinguished with the Carrier President’s Award.  Trust that your best interest is our priority.  At Ferran Services, it’s not about the sale.  It’s all about your long-term satisfaction.
Reinstall the access panel and disconnect block. Turn on the circuit breaker and furnace switch. Then set the thermostat to a lower temperature and wait for the AC to start (see “Be Patient at Startup,” below). The compressor should run and the condenser fan should spin. If the compressor starts but the fan doesn’t, the fan motor is most likely shot. Shut off the power and remove the screws around the condenser cover. Lift the cover and remove the fan blade and motor (photo 7). Reinstall the blade and secure the cover. Then repower the unit and see if the fan starts. If it doesn’t, you’ve given it your best shot—it’s time to call a pro.
A specialized air conditioner that is used only for dehumidifying is called a dehumidifier. It also uses a refrigeration cycle, but differs from a standard air conditioner in that both the evaporator and the condenser are placed in the same air path. A standard air conditioner transfers heat energy out of the room because its condenser coil releases heat outside. However, since all components of the dehumidifier are in the same room, no heat energy is removed. Instead, the electric power consumed by the dehumidifier remains in the room as heat, so the room is actually heated, just as by an electric heater that draws the same amount of power.
Any concern with your cooling system, however minor, is worth checking out.  NATE-certified technicians can quickly identify the problem and prevent more extensive and costly damage.  Catching defects quickly is the key to cost-effective repairs.  Elevated operational noise such as grinding, screeching, or wheezing is more than aggravating.  Think of those sounds as warning bells.  They’re an indication of component failure.  Listen to what they’re telling you and call for professional assistance.  Worn or misaligned belts are easily repaired.  Strange smells from contaminants such as mold or mildew are best handled before allergens enter breathing air, diminish airflow, and block the coil.  Temperature swings, unstable humidity, or extended run times are all signs of bigger problems on the way.  Call Ferran Services at 407-422-3551 (Orlando) or 386-322-6168 (Volusia), and our licensed technicians will perform a complete system check, ensuring safe, efficient and reliable operation.
Vredevoogd Heating & Cooling stands behind its services and products with the strongest guarantees you’ll find anywhere. When you invite us into your home to service or install your HVAC system or do Furnace Repair work in Grand Rapids and beyond, we perform our job with an outstanding level of care and efficiency. Having served Michigan for 54 years, we never rest on our laurels. To remain the best, we intend to give our best every time, every job.
Whether it’s a sticky day in July and you need an AC repair, or your employees are having trouble breathing because of stagnant indoor air, you can rely on HI-VAC Air Conditioning Service to quickly resolve your problem. We are the go-to source for air conditioning services in Plantation, Miramar, Pembroke Pines, Weston, Coral Springs, Sunrise, FL and the surrounding area. Give us a call today to learn how we can improve your indoor comfort.
A mini-split system typically supplies air conditioned and heated air to a single or a few rooms of a building.[38] Multi-zone systems are a common application of ductless systems and allow up to 8 rooms (zones) to be conditioned from a single outdoor unit. Multi-zone systems typically offer a variety of indoor unit styles including wall-mounted, ceiling-mounted, ceiling recessed, and horizontal ducted. Mini-split systems typically produce 9,000 to 36,000 Btu (9,500–38,000 kJ) per hour of cooling. Multi-zone systems provide extended cooling and heating capacity up to 60,000 Btu's.

If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.
Air conditioning and refrigeration are provided through the removal of heat. Heat can be removed through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are referred to as refrigerants. A refrigerant is employed either in a heat pump system in which a compressor is used to drive thermodynamic refrigeration cycle, or in a free cooling system which uses pumps to circulate a cool refrigerant (typically water or a glycol mix).
Dichlorodifluoromethane (R-12) was the most common blend used in automobiles in the U.S. until 1994, when most designs changed to R-134A due to the ozone-depleting potential of R-12. R-11 and R-12 are no longer manufactured in the U.S. for this type of application, so the only source for air-conditioning repair purposes is the cleaned and purified gas recovered from other air conditioner systems. Several non-ozone-depleting refrigerants have been developed as alternatives, including R-410A. It was first commercially used by Carrier Corp. under the brand name Puron.[citation needed]
In 1758, Benjamin Franklin and John Hadley, a chemistry professor at Cambridge University, conducted an experiment to explore the principle of evaporation as a means to rapidly cool an object. Franklin and Hadley confirmed that evaporation of highly volatile liquids (such as alcohol and ether) could be used to drive down the temperature of an object past the freezing point of water. They conducted their experiment with the bulb of a mercury thermometer as their object and with a bellows used to speed up the evaporation. They lowered the temperature of the thermometer bulb down to −14 °C (7 °F) while the ambient temperature was 18 °C (64 °F). Franklin noted that, soon after they passed the freezing point of water 0 °C (32 °F), a thin film of ice formed on the surface of the thermometer's bulb and that the ice mass was about 6 mm (1⁄4 in) thick when they stopped the experiment upon reaching −14 °C (7 °F). Franklin concluded: "From this experiment one may see the possibility of freezing a man to death on a warm summer's day."[9]
In 1902, the first modern electrical air conditioning unit was invented by Willis Carrier in Buffalo, New York.[citation needed] After graduating from Cornell University, Carrier found a job at the Buffalo Forge Company. There, he began experimenting with air conditioning as a way to solve an application problem for the Sackett-Wilhelms Lithographing and Publishing Company in Brooklyn, New York. The first air conditioner, designed and built in Buffalo by Carrier, began working on 17 July 1902.[citation needed]
In the most general sense, air conditioning can refer to any form of technology that modifies the condition of air (heating, (de-) humidification, cooling, cleaning, ventilation, or air movement). In common usage, though, "air conditioning" refers to systems which cool air. In construction, a complete system of heating, ventilation, and air conditioning is referred to as HVAC.[3] 

We contacted GatorAC and have been pleased through the entire process of the purchase, installation and the daily functioning of the unit. We spoke to Angie to get information about the Trane AC. She arranged for Carlos Garcia to come to the house to determine the unit that would fit our needs. We made the choice between 3 units on Thursday and the unit was installed Friday. The Installation team, Willie Shaw and Gary Barber were the best. When they left everything was done, clean and clear and working great. We would recommend GatorAC for your AC needs.
Starting to feel the damp Florida Summer Heat? Without understanding the science, you may think putting in a bigger unit will give you more substantial cooling, but a unit that is not properly sized will cost you more and could cause major humidity problems in your home! Where comfort meets efficiency, that is where you’ll find Ferran, your home performance contractor!
CIBSE publishes several guides to HVAC design relevant to the UK market, and also the Republic of Ireland, Australia, New Zealand and Hong Kong. These guides include various recommended design criteria and standards, some of which are cited within the UK building regulations, and therefore form a legislative requirement for major building services works. The main guides are:

About us: Vredevoogd Heating & Cooling has been in business since 1964. As a financially stable company known for its reliable expertise and first-rate customer care, Vredevoogd Heating & Cooling is a company you can trust. Moreover, when you do business with a stable business like Vredevoogd Heating & Cooling, you have the peace of mind of knowing that your warranties are solidly backed by a company that intends to remain in business for another 50+ years and beyond. Don’t trust your essential home systems and investment to any fly-by-night company. Our best practices ensure that we will be here to meet our customer’s HVAC needs for decades to come. Vredevoogd Heating & Cooling founder Dennis Vredevoogd set the high standards by which the company continues to pride itself for. Today, the company continues to be family owned and operated by the founder’s sons, Michael and Thomas, who are committed to maintaining the company’s high standards and complementing them with the innovative technical know-how needed to service today’s advanced HVAC systems.
Most central air conditioners have two basic parts: an outdoor unit (compressor/condenser) that sits next to your home and an indoor unit (evaporator) that’s located in a central duct near your furnace. If you have a heat pump instead of a furnace, the indoor unit will be in the air handler. Use the same maintenance steps we show here. If your furnace looks different from the one shown or you have a heat pump, use the owner’s manual to find your way around it. The basic parts will be the same. Check out our step-by-step guide for deep-cleaning your home air conditioner.
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
×