Even with the best air conditioning repair service Phoenix can offer, an AC unit that has reached the end of its shelf life must be replaced. If you are ready to upgrade or replace that aging system, call us now for a free estimate, or check out our AC Unit Replacement section. In addition to offering our own Precision Line with the best warranty available in the industry, we also partner with industry leaders to offer the highest quality equipment at the best possible price, and we personally stand behind all of our new equipment installations.

The heat-exchanger cools the air that is being forced through it by the furnace blower. As the warm air comes in contact with this cool surface the water in the air condenses. By pulling the water molecules from the air. According to the psychometric chart[42] as relative humidity decreases in order to feel cool you will have to lower the temperature even more. A common way to counteract this effect is by installing a whole-home humidifier.[43] Similarly, installing a high efficient system this need to turn the temperature down wont have such and influence on your energy costs.
When your furnace isn’t regularly serviced it can operate less efficiently. This increases your energy bills and also prevents your furnace from keeping your home as warm as you like. Keep your furnace properly maintained with regular service. The national average furnace service cost is between $60 and $80. Companies may offer tuneup specials that cover all the necessary testing, tightening, measuring and cleaning to keep your equipment running at top efficiency. If you have a newer system, furnace service costs may be covered by your warranty. Outside of warranty, a basic tuneup might start at $58 and a more advanced maintenance cleaning could be over $120. Here are some signs your furnace may need service:
Gainesville Mechanical Inc is open for regular business hours, Monday through Friday, from 8 a.m. to 5 p.m. We offer everyday extended business hours, at regular rates, to meet the challenge of your busy schedule with flexible appointment times, and always have a licensed technician at your door within 24 hours.  For desperate times, we protect your home, comfort, and safety with 24/7 Emergency Assistance without added after-hour costs.  Contact us at 770-532-9130, and rest assured, we prioritize your best interests.  Our skilled service never comes with inflated or hidden charges.  We provide affordable rates, upfront pricing, and the detailed information you need to make the best possible decisions.  We service all makes and models of cooling equipment, optimizing safety, efficiency, and reliability, to deliver superior, ongoing performance.  Trust our award-winning team of NATE-certified technicians to restore your comfort today, with repairs that ensure long-term satisfaction.
Demand controlled kitchen ventilation (DCKV) is a building controls approach of slowing down kitchen exhaust fans and subsequent supply air in response to the actual cooking loads in a commercial kitchen. Traditional commercial kitchen ventilation systems operate at 100% fan speed independent of the volume of cooking activity and DCKV technology changes that to provide significant fan energy and conditioned air savings. By deploying smart sensing technology, both the exhaust and supply fans can be controlled to capitalize on the Law of Affinity for motor energy savings, reduce makeup air heating and cooling energy, increasing safety and reducing ambient kitchen noise levels.[30]
Bonney’s NATE certified technicians will troubleshoot and repair your furnace for safe and reliable operation. Our technicians use state of the art tools including video inspection cameras and exhaust gas analyzers to perform thorough, comprehensive diagnostics when equipment is broken. Furthermore, we arrive in a “warehouse on wheels” stocked with many parts to get your furnace repaired as quickly as possible.  For an unexpected heater repair Bonney offers financing to make your comfort affordable.
In 1992, a non-governmental organization, Greenpeace, was spurred by corporate executive policies and requested that a European lab find substitute refrigerants. This led to two alternatives, one a blend of propane (R290) and isobutane (R600a), and one of pure isobutane.[18][22] Industry resisted change in Europe until 1993, and in the U.S. until 2011, despite some supportive steps in 2004 and 2008 (see Refrigerant Development above).[27][68]
The most recognized standards for HVAC design are based on ASHRAE data. The most general of four volumes of the ASHRAE Handbook is Fundamentals; it includes heating and cooling calculations. Each volume of the ASHRAE Handbook is updated every four years. The design professional must consult ASHRAE data for the standards of design and care as the typical building codes provide little to no information on HVAC design practices; codes such as the UMC and IMC do include much detail on installation requirements, however. Other useful reference materials include items from SMACNA, ACGIH, and technical trade journals.
Mr. Plumber provides fast, expert plumbing service to Smyrna, GA and is here for you with 24 hour emergency plumbing service. Our licensed and certified plumbers can tackle all your plumbing jobs including sink & faucet repair, toilet repair & replacement, water line repair & replacement, drain cleaning, bathtubs & shower installation and repair, water heater installation, sewer repair, backflow prevention and more. Our professional plumbers will respect your time, home and business. You approve the price before we perform our plumbing work and your satisfaction is guaranteed! Give us a call today for:
Please give us a call today at 1-800-948-MIKE (6453) for first-class air conditioning service and repairs in the Springfield, VA, Rockville, Silver Spring, MD & Washington D.C. metro area. We’re open seven days a week and provide 24/7 emergency service. For those who want to ensure that their AC unit is in working order before the summer season begins – or at any other time – we proudly offer a Heating & Cooling precision tune up to troubleshoot any potential AC problems. Upon completion of the AC inspection, we will provide you with a comprehensive written report regarding your Air Conditioning and Heating system’s status and make any recommendations necessary to improve your comfort level and head off any problems before they arise.

Precision’s technicians are all NATE certified. This is the highest certification in the air conditioning industry. With that, we can take pride in saying that we provide the best AC repair Phoenix residents can get. Our technicians are thoroughly screened and tested before they begin work on your home. Our AC technicians provide top-notch Phoenix air conditioning repair, and proof of that is their ability to repair most every brand of HVAC equipment. These brands include Trane, Bryant, Ruud, Goodman, Amana, Precision, Armstrong, Carrier, Coleman, Honeywell, Janitrol, Lennox, Payne, Rheem, York, Goettl, American Standard along with many more.


The selection of the working fluids (refrigerants) has a significant impact not only on the performance of the air conditioners but on the environment as well. Most refrigerants used for air conditioning contribute to global warming, and many also deplete the ozone layer.[60] CFCs, HCFCs, and HFCs are potent greenhouse gases when leaked to the atmosphere.
A contactor is a $25 mechanical relay that uses low-voltage power from the thermostat to switch 220-volt high-amperage current to the compressor and condenser fan. AC contactors can wear out and are at the top of the list of common air conditioning service failures. Even if your contactor is working, it pays to replace it every five years or so. Unscrew the old contactor before removing the wires. Then move the wires to the new unit (photo 6).
The Chartered Institution of Building Services Engineers is a body that covers the essential Service (systems architecture) that allow buildings to operate. It includes the electrotechnical, heating, ventilating, air conditioning, refrigeration and plumbing industries. To train as a building services engineer, the academic requirements are GCSEs (A-C) / Standard Grades (1-3) in Maths and Science, which are important in measurements, planning and theory. Employers will often want a degree in a branch of engineering, such as building environment engineering, electrical engineering or mechanical engineering. To become a full member of CIBSE, and so also to be registered by the Engineering Council UK as a chartered engineer, engineers must also attain an Honours Degree and a master's degree in a relevant engineering subject.
We want to compliment your fine sales and installation team. They are outstanding. Carlos, your sales rep., was highly informative. We reviewed our needs and we ultimately chose the Trane XV-18 variable speed system. Carlos did not try to up sell us with things that we did not need but he did help us choose the correct upgraded filter and UV light that we wanted. We told Carlos that our research indicated that the quality of the installation of the unit was at least as important as the unit itself, and Carlos agreed. Carlos pointed out that new proper sized duct work and copper wiring would be required for a correct installation, and that we needed to add two more returns. We asked if more returns were needed and Carlos said that would not be cost effective. That was great to hear. Carlos assured us that the installation team of Willie and Gary, both lead installers, would be used. They were both superb. They came on time and worked for 12 and 1/2 hours. It was a 93 degree day so the heat in the attic was intense. We kept telling them to take a break but they continued to work up there in what must have been 130+ temperatures. They were amazing! They were neat and cleaned up any mess they made. They patiently answered all of our many questions and gave us helpful tips. They were truly professional in all respects. We also note that Stacy, Angie and Karen of your office staff were each courteous, accommodating and efficient. They helped things to go smoothly. Carlos, Gary, Stacy, Angie, Willie and Karen are each great assets to your company. We would be comfortable recommending that team of people to anyone! Ken and Kathy Luban
Our furnace quit lighting yesterday. I called Cool Tech around 7pm and they offered to come out after hours, but I chose to set up an appointment today. The technician John called me at 7:30am and was there about 8am as promised. He was very courteous and replaced the igniter quickly. The heater is back to working properly. This is my second time hiring Cool Tech and they will continue to be my go-to heating and air conditioning guys.
Inspect your furnace thermostat by first making sure that it’s turned on. Also, ensure that the thermostat switch is turned to “heat” and not “cool”. If your furnace will still not start with the thermostat on, try adjusting the temperature settings to a few degrees higher. Inspect any visible wires for breaks or splits, and make sure your thermostat batteries are not dead. Do not touch any open wires; contact a professional.
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
A lot of heat enters the home through windows, especially open windows. If you really want to control heat in your house, pay attention to your windows, too. Keep them closed and covered with blinds or drapes during the hottest parts of the day—especially windows that are currently facing the sun. Here are more tips for cutting cooling costs this season.
As a top provider of top-rated air conditioners and professional service, Four Seasons Heating and Air Conditioning is here to ensure that you have the cool and comfortable living environment that you deserve. Learn more about what we have to offer today by giving us a call, or request additional information now by filling out our brief online quote form!

Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
×