Whether it’s a sticky day in July and you need an AC repair, or your employees are having trouble breathing because of stagnant indoor air, you can rely on HI-VAC Air Conditioning Service to quickly resolve your problem. We are the go-to source for air conditioning services in Plantation, Miramar, Pembroke Pines, Weston, Coral Springs, Sunrise, FL and the surrounding area. Give us a call today to learn how we can improve your indoor comfort.

Allow our experts to help with any of your heating and cooling needs or questions. Our wide array of expertise and background will benefit you and your home, whether you are considering a replacement system or evaluating your whole system to check for areas of improvement. We can help you reach your optimum indoor comfort. Give us a ring at 866-397-3787 or request an appointment online.
Drug-screened and always dressed professionally in uniform, the team of heating and cooling technicians from Kabran Air Conditioning & Heating respects your time, property, and investment. Through organized project management and competitive pricing, we ensure a rewarding start-to-finish experience.  We offer free estimates on system upgrades, extended Emergency Service hours, and convenient and affordable maintenance plans.  When you take advantage of membership in the KABRAN Cool Club, you’ll benefit from superior savings, priority scheduling, and much more.  Let us protect your comfort, safety, and investment with regular inspection and meticulous tuning.
AC air handler squealing or grinding noises. Though most air handlers have direct-drive motors, some older units may be belt-driven. Squealing sounds from a belt-drive air handler generally occur when the belt that connects the motor to the blower slips. In most cases, the belt is improperly aligned or worn and needs replacement. Follow the instructions above under Air Conditioner Not Blowing Air and refer to your owner’s manual.
Air-source heat pumps are more popular in milder winter climates where the temperature is frequently in the range of 4–13 °C (40–55 °F), because heat pumps become inefficient in more extreme cold. This is because ice forms on the outdoor unit's heat exchanger coil, which blocks air flow over the coil. To compensate for this, the heat pump system must temporarily switch back into the regular air conditioning mode to switch the outdoor evaporator coil back to being the condenser coil, so that it can heat up and defrost. A heat pump system will therefore have a form of electric resistance heating in the indoor air path that is activated only in this mode in order to compensate for the temporary indoor air cooling, which would otherwise be uncomfortable in the winter.
Designed to improve manufacturing process control in a printing plant, Carrier's invention controlled not only temperature but also humidity. Carrier used his knowledge of the heating of objects with steam and reversed the process. Instead of sending air through hot coils, he sent it through cold coils (filled with cold water). The air was cooled, and thereby the amount of moisture in the air could be controlled, which in turn made the humidity in the room controllable. The controlled temperature and humidity helped maintain consistent paper dimensions and ink alignment. Later, Carrier's technology was applied to increase productivity in the workplace, and The Carrier Air Conditioning Company of America was formed to meet rising demand. Over time, air conditioning came to be used to improve comfort in homes and automobiles as well. Residential sales expanded dramatically in the 1950s.[citation needed]
We happily offer all of our services in St Marys county. We view our neighbors in St. Mary’s county as important and valuable as our friends in Calvert. If you live in St Marys and you’re not sure if we can help you with your specific problem, please don’t hesitate to contact us and find out! We value all inquiries and our eager to help and assist our neighbors throughout all of Southern Maryland.

Shortly thereafter, the first private home to have air conditioning was built in Minneapolis in 1914, owned by Charles Gates.[11] Realizing that air conditioning would one day be a standard feature of private homes, particularly in regions with warmer climate, David St. Pierre DuBose (1898-1994) designed a network of ductwork and vents for his home Meadowmont, all disguised behind intricate and attractive Georgian-style open moldings.[when?] This building is believed to be one of the first private homes in the United States equipped for central air conditioning.[12]
Our furnace quit lighting yesterday. I called Cool Tech around 7pm and they offered to come out after hours, but I chose to set up an appointment today. The technician John called me at 7:30am and was there about 8am as promised. He was very courteous and replaced the igniter quickly. The heater is back to working properly. This is my second time hiring Cool Tech and they will continue to be my go-to heating and air conditioning guys.

Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
Most central air conditioners are connected to a home's forced-air distribution system. Thus, the same motor, blower, and ductwork used for heating are used to distribute cool air from the air conditioning system. When a central air conditioner is operating, hot air inside the house flows to the furnace through the return-air duct. The hot air is moved by the blower across the cooled evaporator coil in the plenum and is then delivered through ducts to cool the house. When the air conditioner works but the house doesn't cool, the problem is probably in the distribution system.
We contacted GatorAC and have been pleased through the entire process of the purchase, installation and the daily functioning of the unit. We spoke to Angie to get information about the Trane AC. She arranged for Carlos Garcia to come to the house to determine the unit that would fit our needs. We made the choice between 3 units on Thursday and the unit was installed Friday. The Installation team, Willie Shaw and Gary Barber were the best. When they left everything was done, clean and clear and working great. We would recommend GatorAC for your AC needs.
Vredevoogd Heating & Cooling Grand Rapids values each and every customer. Servicing or installing your HVAC system means establishing a service relationship with each homeowner. We promise to earn your trust with our consummate level of professionalism and expert service. We back our work with the strongest industry guarantees because we value your continued business.
An electric furnace provides warmth by moving air over and through a series of coils. Ductwork and vents then distribute that air to the individual rooms in your home. Repair costs will depend on both the brand and the exact nature of the problem, but tend to be lower than some of the options above. That's because the units are small, and issues tend to be contained within the heating elements themselves. Expect to spend less than $300 on your electric furnace repair, depending on the exact problem.
Your furnace's flame sensor is essentially a safety mechanism. As a thin metallic rod in front of the flame inside the unit, it's sole purpose is to confirm that your gas valves only open when a flame actually exists to burn that gas. When the flame sensor stop working, on the other hand, gas leaks can occur. To repair your furnace's flame sensor, expect to spend between $80 and $250. Even a full replacement of this part typically does not go above that range.

In 1758, Benjamin Franklin and John Hadley, a chemistry professor at Cambridge University, conducted an experiment to explore the principle of evaporation as a means to rapidly cool an object. Franklin and Hadley confirmed that evaporation of highly volatile liquids (such as alcohol and ether) could be used to drive down the temperature of an object past the freezing point of water. They conducted their experiment with the bulb of a mercury thermometer as their object and with a bellows used to speed up the evaporation. They lowered the temperature of the thermometer bulb down to −14 °C (7 °F) while the ambient temperature was 18 °C (64 °F). Franklin noted that, soon after they passed the freezing point of water 0 °C (32 °F), a thin film of ice formed on the surface of the thermometer's bulb and that the ice mass was about 6 mm (1⁄4 in) thick when they stopped the experiment upon reaching −14 °C (7 °F). Franklin concluded: "From this experiment one may see the possibility of freezing a man to death on a warm summer's day."[9]
1) Your air conditioner is not working at all. Before calling in a professional to address this issue, you may want to check a few things yourself. Check to see if your thermostat is set to “cool”. Confirm that your designated cooling temperature is less than the temperature of the room or home. If everything is set correctly, check the electrical panel to be sure you do not have a tripped breaker. If these things all check out and your air condition unit is still not working, it is time to call in a professional.
If your AC doesn’t turn off when room temperature reaches the temperature set on the thermostat, the problem is generally occurring either at the thermostat or in the electrical system that runs the outside condensing unit. You can use the AC’s circuit breaker to shut off the unit, but that should not be a permanent solution—circuit breakers are not designed to be used like light switches.
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).

Evaporative coolers tend to feel as if they are not working during times of high humidity, when there is not much dry air with which the coolers can work to make the air as cool as possible for dwelling occupants. Unlike other types of air conditioners, evaporative coolers rely on the outside air to be channeled through cooler pads that cool the air before it reaches the inside of a house through its air duct system; this cooled outside air must be allowed to push the warmer air within the house out through an exhaust opening such as an open door or window.[28] These coolers cost less and are mechanically simple to understand and maintain.
When natural gas, propane or heating oil are burned in a furnace, the resulting hot combustion gasses by burning natural gas, propane or heating oil circulate through a heat exchanger. The heat exchanger will, in turn, release that heat to be circulated by the furnace’s blower. The flue gas then travels through the flue vent, which carries the gas outside of the home. When a heat exchanger is cracked, it generally will require a complete system replacement. That is one of the reasons why we highly recommend annual preventive maintenance on your home’s furnace – this preventative furnace inspection and maintenance can greatly prolong the life of your home heating system. 

Modern air conditioning systems are not designed to draw air into the room from the outside, they only recirculate the increasingly cool air on the inside. Because this inside air always has some amount of moisture suspended in it, the cooling portion of the process always causes ambient warm water vapor to condense on the cooling coils and to drip from them down onto a catch tray at the bottom of the unit from which it must then be routed outside, usually through a drain hole. As this moisture has no dissolved minerals in it, it will not cause mineral buildup on the coils. This will happen even if the ambient humidity level is low. If ice begins to form on the evaporative fins, it will reduce circulation efficiency and cause the development of more ice, etc. A clean and strong circulatory fan can help prevent this, as will raising the target cool temperature of the unit's thermostat to a point that the compressor is allowed to turn off occasionally. A failing thermistor may also cause this problem. Refrigerators without a defrost cycle may have this same issue. Dust can also cause the fins to begin blocking air flow with the same undesirable result: ice.
When the time comes to schedule furnace repairs, you want a team you can trust. Keeping your home warm and comfortable is important for you and your family, which is why you should rely on the highly-trained team of technicians at Horizon Services. Our techs undergo at least 150 hours of technical training every year and are up-to-date on the latest, most advanced techniques in the trade. We also background-check all of our employees to ensure your complete comfort and safety. When you call on us for furnace repair, we will arrive on-time and on schedule, ready to resolve the issue as quickly as possible.
Your furnace's flame sensor is essentially a safety mechanism. As a thin metallic rod in front of the flame inside the unit, it's sole purpose is to confirm that your gas valves only open when a flame actually exists to burn that gas. When the flame sensor stop working, on the other hand, gas leaks can occur. To repair your furnace's flame sensor, expect to spend between $80 and $250. Even a full replacement of this part typically does not go above that range.
For starters, once a year, vacuum out the area around the furnace’s blower. If possible, also slide out the fan unit, clean each fan blade with a toothbrush, and then vacuum with a brush attachment on a vacuum cleaner. While you’re at it, look for oil ports on the motor, normally located near the motor shaft. If the motor has these, apply two to three drops of non-detergent motor oil into each port (you may have to remove a cover plate to do this). Though most contemporary motors don’t require lubrication, do lubricate motors with oil ports once a year. For more about maintenance, see Maintenance Checklist for Central Heating Systems.
Most modern air-conditioning systems feature a dehumidification cycle during which the compressor runs while the fan is slowed as much as possible[citation needed] to reduce the evaporator temperature and therefore condense more water. When the temperature falls below a threshold, both the fan and compressor are shut off to mitigate further temperature drops;[clarification needed] this prevents moisture on the evaporator from being blown back into the room.[citation needed] When the temperature rises again,[clarification needed] the compressor restarts and the fan returns to low speed.
The performance of vapor compression refrigeration cycles[27] is limited by thermodynamics. These air conditioning and heat pump devices move heat rather than convert it from one form to another, so thermal efficiencies do not appropriately describe the performance of these devices. The Coefficient-of-Performance (COP) measures performance, but this dimensionless measure has not been adopted. Instead, the Energy Efficiency Ratio (EER) has traditionally been used to characterize the performance of many HVAC systems. EER is the Energy Efficiency Ratio based on a 35 °C (95 °F) outdoor temperature. To more accurately describe the performance of air conditioning equipment over a typical cooling season a modified version of the EER, the Seasonal Energy Efficiency Ratio (SEER), or in Europe the ESEER, is used. SEER ratings are based on seasonal temperature averages instead of a constant 35 °C (95 °F) outdoor temperature. The current industry minimum SEER rating is 14 SEER.[28]
Before opening the electrical cover on the A/C unit, be sure to shut off all power to the compressor unit and the indoor furnace or air handler, and verify that it is off. Note that this may mean shutting off a circuit breaker that serves the furnace and air handler, and then, near the compressor, pulling out the disconnect block (or shutting off the 220-volt power) to the outdoor compressor.

1) Change your filter. The simplest and most effective way to keep your AC running smoothly is changing your filter once a month. By regularly changing your filter, you reduce a lot of the burden on your system. A dirty or clogged filter makes your air conditioner work much harder than does a clean filter. Changing your filters regularly is easy on your budget and easy on your system as well. It will lower your utility bill and extend the life of your AC.
If you live in a warmer climate, your air conditioner is likely one of the most essential pieces of equipment for your home. The best course is to perform regular routine air conditioner maintenance to ensure its smooth operation during the warmest months of the year. Annual tune-ups by a professional HVAC technician will increase the lifespan of your unit. When repairs are needed, be sure to hire a technician trained and certified in HVAC repair for best results. Following these guidelines will ensure that you are comfortable and cool through the summer season.
×