©2019 By Horizon Services, LLC. All Rights Reserved. DE License # PL0000726, HL0000299. Contractor Reg. # PA017876, PA057742. NJ Plumbing Lic. # PL36BI01232300 - David Geiger HIC reg. # 13VH05117300, NJ Master HVACR contractor Lic. # 19HC00193700. MD Master HVACR contractor Lic. # 47186, MD Master Plumber/Gas Fitter Lic. # 63739 – David Geiger. EL.LIC./B.P. #34EI01207700.
The heat-exchanger cools the air that is being forced through it by the furnace blower. As the warm air comes in contact with this cool surface the water in the air condenses. By pulling the water molecules from the air. According to the psychometric chart[42] as relative humidity decreases in order to feel cool you will have to lower the temperature even more. A common way to counteract this effect is by installing a whole-home humidifier.[43] Similarly, installing a high efficient system this need to turn the temperature down wont have such and influence on your energy costs.

*We work on all brands: Adams, Aire-Flo, Amana, Arcoaire, Armstrong, Beutler, Bryant, Carrier, Centurion, Coleman, Comfortmaker, Cozy, Daikin, Day & Night, Dayton, Ducane, Emerson, Empire, Evcon, Fedders, Friedrich, Frigidaire, Fujitsu, Gaffers & Statler, General Electric, Gibson, Goldstar, Goodman, GMC, Haier, Heil, Honeywell, Intertherm, Janitrol, Kenmore, Lennox, Luxaire, Maytag, Mitsubishi, Payne, Rheem, Ruud, Samsung, Sanyo, Sears, Sharp, Spartan, Tappan, Tempstar, Thermal Solutions, Trane, Utica, Weatherking, Westinghouse, Whirlpool, Williams, York, and Zephyr.
Evaporative coolers tend to feel as if they are not working during times of high humidity, when there is not much dry air with which the coolers can work to make the air as cool as possible for dwelling occupants. Unlike other types of air conditioners, evaporative coolers rely on the outside air to be channeled through cooler pads that cool the air before it reaches the inside of a house through its air duct system; this cooled outside air must be allowed to push the warmer air within the house out through an exhaust opening such as an open door or window.[28] These coolers cost less and are mechanically simple to understand and maintain.
Replacing a capacitor is easy. Just take a photo of the wires before disconnecting anything (you may need a reference later on). Then discharge the stored energy in the old capacitor (Photo 4). Use needle-nose pliers to pluck one wire at a time from the old capacitor and snap it onto the corresponding tab of the new capacitor. The female crimp connectors should snap tightly onto the capacitor tabs. Wiggle each connector to see if it’s tight. If it’s not, remove the connector and bend the rounded edges of it so it makes a tighter fit on the tab. When you’ve swapped all the wires, secure the new capacitor (Photo 5).
You might guess it from the name: the heat exchanger is the part of your furnace that actually heats the air your blower motor pushes through the furnace. It consists of a chamber in which the heat energy produced by natural or propane gas is transferred to the forced air. At the same time, this part also includes a vent through which the gases themselves are safely removed from the unit and the air that enters your home. Because of these gases, a problem with your heat exchanger needs to be dealt with promptly. Over time, cracks in the exchanger can result in carbon monoxide leaks. Taking care of the problem once again means understanding the existence of a range: repairing your heat exchanger can cost as little as $100, but a full replacement may cost up to $1,200.

The belt should slip right into place. If it seems to be too tight or difficult to set in place, it may be necessary to adjust the motor mount to provide more slack. Then you can re-tighten the tension once the belt is in place. Check the manufacturer’s specifications for proper tension—in most cases, the belt should deflect about an inch when you press down on it.
If you have a heating or cooling emergency, call Vredevoogd Heating & Cooling Grand Rapids MI, Furnace Repair Lansing, Furnace Repair Kalamazoo and more at 616-828-5411. When you call you speak directly with one of our service representatives about the problem you are experiencing and schedule a service appointment. Naturally, we prioritize emergencies so you can count on us when your heating or cooling systems fail. After regular business hours, you can reach our customer service staff who will report your problem to on-call technicians. You can expect to hear back from a certified tech within 15 minutes of your call. Your heating and cooling emergency is important to us. We will visit your home ASAP to provide you with the superior service you’d expect from a Furnace Repair, Air Conditioning, AC Repair & HVAC leader like Vredevoogd Heating & Cooling Grand Rapids, AC Repair Lansing, AC Repair Kalamazoo.
Our team of fully licensed and insured technicians each draw from between ten and thirty years of industry experience and share our unwavering dedication to customer service.  Entirely NATE-certified, our installation and service department has completed rigorous testing, and are exceptionally qualified to handle even the most complex HVAC challenges.  NATE (North American Technician Excellence) is the only nationwide certification program that is supported by the entire industry, and of all third-party certifications, has the lowest pass rate.
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
×