If a heat exchanger cracks or contains holes, leaks can release carbon monoxide into your home. Carbon monoxide is nearly impossible for humans to detect on their own due to its characteristics of being colorless and odorless. Because of this, it is referred to as “The Silent Killer”. Some symptoms of carbon monoxide poisoning include headache, dizziness, fatigue, nausea and vomiting. It is extremely important to have a HVAC technician perform a furnace inspection annually to prevent problems such as carbon monoxide poisoning. UGI Heating, Cooling & Plumbing offers yearly maintenance packages and service agreements that include yearly maintenance and furnace inspections.
The belt should slip right into place. If it seems to be too tight or difficult to set in place, it may be necessary to adjust the motor mount to provide more slack. Then you can re-tighten the tension once the belt is in place. Check the manufacturer’s specifications for proper tension—in most cases, the belt should deflect about an inch when you press down on it.
Your furnace's flame sensor is essentially a safety mechanism. As a thin metallic rod in front of the flame inside the unit, it's sole purpose is to confirm that your gas valves only open when a flame actually exists to burn that gas. When the flame sensor stop working, on the other hand, gas leaks can occur. To repair your furnace's flame sensor, expect to spend between $80 and $250. Even a full replacement of this part typically does not go above that range.

Dehumidification (air drying) in an air conditioning system is provided by the evaporator. Since the evaporator operates at a temperature below the dew point, moisture in the air condenses on the evaporator coil tubes. This moisture is collected at the bottom of the evaporator in a pan and removed by piping to a central drain or onto the ground outside.


Air conditioning can also be provided by a process called free cooling which uses pumps to circulate a coolant (typically water or a glycol mix) from a cold source, which in turn acts as a heat sink for the energy that is removed from the cooled space. Common storage media are deep aquifers or a natural underground rock mass accessed via a cluster of small-diameter boreholes, equipped with heat exchanger. Some systems with small storage capacity are hybrid systems, using free cooling early in the cooling season, and later employing a heat pump to chill the circulation coming from the storage. The heat pump is added because the temperature of the storage gradually increases during the cooling season, thereby declining its effectiveness.

During our formative years, we were a member of the Refrigeration Service Engineers Society (RSES). Since then, we have been a long-standing member of the Better Business Bureau (BBB) and are closely aligned with Trane. We are a Certified Trane Dealer and Trane Comfort Specialist—the highest level of certification awarded by Trane. In fact, we have earned the Trane Distinguished Dealer Award 11 times!

Many disconnect blocks contain two cartridge fuses. Check them before you proceed with repairs (Photo 3). A blown fuse is a sign of a failing part inside the condensing unit. So don’t just replace it and think you’ve solved the problem. Instead, replace the parts we show here. Then install new fuses and fire up the unit. If it blows again, call a pro—you’ve got more serious issues.
Heating, ventilation, and air conditioning (HVAC[1]) is the technology of indoor and vehicular environmental comfort. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation, as HVAC&R or HVACR or "ventilation" is dropped, as in HACR (as in the designation of HACR-rated circuit breakers).
Air Conditioning Your home's air conditioner is an essential part of your overall indoor comfort. A properly working system can mean the difference between a cool, comfortable summer and a hot, miserable few months. If you're currently dealing with a broken air conditioner, an inefficient system, or you would like to schedule a routine, pre-season tune-up, Horizon Services is here to help!
5) Your air conditioner is short cycling. It is perfectly normal for your air conditioner to cycle on and off to maintain a set temperature throughout your home. However, if you notice that it is turning on and off more frequently than usual and the outside temperature is not particularly warmer than normal, it is possible that your unit is malfunctioning. Short cycling puts extra stress on your air conditioner, and can cause it to fail if not handled quickly. 

Handling the service needs of homeowners throughout Orlando, FL, Volusia, FL since 1910, we’ve built our business on a foundation of well-earned trust.  We uphold an A+ rating from the Better Business Bureau.  As a Carrier Factory Authorized Dealer, Ferran Services has been further distinguished with the Carrier President’s Award.  Trust that your best interest is our priority.  At Ferran Services, it’s not about the sale.  It’s all about your long-term satisfaction.
Put simply, any home that uses air pushed through ductwork for heating purposes takes advantage of forced air heating. In other words, this term refers not to your furnace, but to the delivery method of the heat throughout your home. Forced air heating is possible with electric or gas furnaces, or a heat pump. Any issues with this delivery system that aren't directly related to the furnace likely have to do with the duct work, which costs between $35 and $55 per linear square foot to repair, or the air handling unit.
The selection of the working fluids (refrigerants) has a significant impact not only on the performance of the air conditioners but on the environment as well. Most refrigerants used for air conditioning contribute to global warming, and many also deplete the ozone layer.[60] CFCs, HCFCs, and HFCs are potent greenhouse gases when leaked to the atmosphere.
We had an exceptional experience with Gator Air, in particular Carlos. He presented us with quotes for different types of AC units, told us facts about said units and left us to make our decision. No high pressure sales. The installers were professional and cleaned up when they were through. A nice surprise was the 1 year free maintenance of the unit. We belonged to the Gator Club so to not have to pay it for the next year was an added bonus. Thank you GatorAir for making the experience an enjoyable one.
Mr. Plumber provides fast, expert plumbing service to Smyrna, GA and is here for you with 24 hour emergency plumbing service. Our licensed and certified plumbers can tackle all your plumbing jobs including sink & faucet repair, toilet repair & replacement, water line repair & replacement, drain cleaning, bathtubs & shower installation and repair, water heater installation, sewer repair, backflow prevention and more. Our professional plumbers will respect your time, home and business. You approve the price before we perform our plumbing work and your satisfaction is guaranteed! Give us a call today for:

We believe that the key to our growing business success is our front-liners. Our team is composed of highly-trained technicians, electricians, and building professionals who are dedicated to providing excellent service. They work with clients to understand their needs and provide the most suitable but cost-effective solutions to property maintenance.
1) Change your filter. The simplest and most effective way to keep your AC running smoothly is changing your filter once a month. By regularly changing your filter, you reduce a lot of the burden on your system. A dirty or clogged filter makes your air conditioner work much harder than does a clean filter. Changing your filters regularly is easy on your budget and easy on your system as well. It will lower your utility bill and extend the life of your AC.
AC units and thermostats have built-in delay features when they’re shut down and then repowered. The delay can be as long as 10 minutes. And, if you’ve subscribed to an energy-saving device from your local power utility, the unit can take even longer to reset. If you’ve installed the parts shown and reinstalled the disconnect block, repowered the circuit breaker, turned on the switch at the furnace, moved the thermostat to AC mode and lowered the temperature below the indoor temperature, and the unit doesn’t fire up after 30 minutes, it’s time to call a pro.
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
×