As a technical industry, the heating and cooling field is associated with annual advances. New energies make our industry an exciting place to work. Our team thrives on keeping up to date with all changes in the HVAC field. We are here to share our knowledge with each customer. When you are ready to update your HVAC system, we can help you select the ideal system for your home.
Circulating refrigerant vapor enters the compressor, where its pressure and temperature are increased. The hot, compressed refrigerant vapor is now at a temperature and pressure at which it can be condensed and is routed through a condenser. Here it is cooled by air flowing across the condenser coils and condensed into a liquid. Thus, the circulating refrigerant removes heat from the system and the heat is carried away by the air. The removal of this heat can be greatly augmented by pouring water over the condenser coils, making it much cooler when it hits the expansion valve.
Our tenant called at 8:00 pm on a Friday night to say the air conditioner was not working. We placed a call to Gator and immediately received a call from the tech asking for tenant's name and contact information. He called back after visiting the sight to say he got the system working again but recommended we install a new unit. My husband met with Carlos a few days later and scheduled installation for the following week. Carlos met with my husband again after the installation to go over the details of the new unit and to ensure he was satisfied with the job. The installers Brandon Hayword and Christian Winslow not only did a top-notch job, but they left the work site exactly how they found it. From start to finish, my husband and I were impressed by the level of professionalism exhibited by all of Gator's employees. We decided Gator is our new HVAC company.
In the UK, the Ozone Regulations[63] came into force in 2000 and banned the use of ozone depleting HCFC refrigerants such as R22 in new systems. The Regulation banned the use of R22 as a "top-up" fluid for maintenance between 2010 (for virgin fluid) and 2015 (for recycled fluid). This means that equipment that uses R22 can still operate, as long as it does not leak. Although R22 is now banned, units that use the refrigerant can still be serviced and maintained.
In modern buildings, the design, installation, and control systems of these functions are integrated into one or more HVAC systems. For very small buildings, contractors normally estimate the capacity and type of system needed and then design the system, selecting the appropriate refrigerant and various components needed. For larger buildings, building service designers, mechanical engineers, or building services engineers analyze, design, and specify the HVAC systems. Specialty mechanical contractors then fabricate and commission the systems. Building permits and code-compliance inspections of the installations are normally required for all sizes of building.

2) Keep your coils clean. The AC coils and fins on the outside of your unit need to be kept clean and clear of obstructions. Leaves and other debris sometimes accumulate around your unit. If obstructions are present, your unit must work harder to function than it should. You can clean your unit with a regular garden hose and a broom. Do not use a pressure washer, as the strong spray could cause harm to your system. A little bit of housekeeping in this regard goes far toward keeping your air conditioner working optimally. 

Many heating and air conditioning companies are only interested in selling you equipment and service agreements. We’re interested in doing what’s best for our customers and in building and maintaining life-long relationships. With more than 55 years of service to the Tulsa, Oklahoma area, you can rest assured that our reputation and longevity speak for itself. We are easy to do business with!

The Environmental Protection Agency (EPA) requires that all technicians who open a system containing a controlled refrigerant be certified to do so. There are four levels of certification, one of which is a “universal” certification to allow the HVAC technician to work on any type of equipment containing refrigerant. Your HVAC technician should be certified as “Level II Certified” at a minimum or, preferably, “Universal Certification” to work on your central air conditioner. Obtaining this certification information from your professional HVAC technician may be required in the event you are working with a realtor to sell your home. Costs for certification average $40 to $240.
Put simply, any home that uses air pushed through ductwork for heating purposes takes advantage of forced air heating. In other words, this term refers not to your furnace, but to the delivery method of the heat throughout your home. Forced air heating is possible with electric or gas furnaces, or a heat pump. Any issues with this delivery system that aren't directly related to the furnace likely have to do with the duct work, which costs between $35 and $55 per linear square foot to repair, or the air handling unit.

Most central air conditioners are connected to a home's forced-air distribution system. Thus, the same motor, blower, and ductwork used for heating are used to distribute cool air from the air conditioning system. When a central air conditioner is operating, hot air inside the house flows to the furnace through the return-air duct. The hot air is moved by the blower across the cooled evaporator coil in the plenum and is then delivered through ducts to cool the house. When the air conditioner works but the house doesn't cool, the problem is probably in the distribution system.
The cost to replace your gas furnace will vary based on the type and size of furnace you select, labor and installation costs, and any repairs your HVAC system may need. Nationally, average HVAC prices for a heating specialist range between $1,800 and $2,500. It’s important to select the right size gas furnace for your heating needs. A furnace that’s too small won’t heat your house properly, while a furnace that’s too large will run inefficiently, cycling on and off and likely breaking down sooner. HVAC specialists calculate your exact heat needs by measuring your home and incorporating variables such as the regional climate and your home’s level of insulation. Retail pricing for gas furnaces can range from $650 up to $3,000 and more. The higher the AFUE (annual fuel utilization efficiency) rating of the furnace, the more efficient it is at turning fuel into heat and the lower your carbon footprint and utility bill will be. HVAC installation costs are often based on an hourly rate and can range from under $50 to over $100 per hour, depending on the company and the furnace being installed. Higher-end furnaces cost more to install because they require added labor and expertise. For a typical installation, it might take two HVAC installation pros one day or less to remove your old furnace and replace it with a new one.
Kabran Air Conditioning & Heating is the first choice for heating and air conditioning on the Florida Space Coast! In addition to providing exceptional HVAC service, repair and installation, we also offer great deals and savings for our customers across Cocoa Beach FL, Satellite Beach FL, Cape Canaveral FL, Rockledge FL, Melbourne FL, Merritt Island FL, Viera FL, Indian Harbour Beach FL. Join our Cool Club to enjoy exclusive, member-only offers. Visit our special offers page today to see what we’re currently offering, and contact Kabran Air Conditioning & Heating for affordable heating and AC service in Cocoa Beach.
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
As a top provider of top-rated air conditioners and professional service, Four Seasons Heating and Air Conditioning is here to ensure that you have the cool and comfortable living environment that you deserve. Learn more about what we have to offer today by giving us a call, or request additional information now by filling out our brief online quote form!
Without proper ventilation, carbon monoxide can be lethal at concentrations of 1000 ppm (0.1%). However, at several hundred ppm, carbon monoxide exposure induces headaches, fatigue, nausea, and vomiting. Carbon monoxide binds with hemoglobin in the blood, forming carboxyhemoglobin, reducing the blood's ability to transport oxygen. The primary health concerns associated with carbon monoxide exposure are its cardiovascular and neurobehavioral effects. Carbon monoxide can cause atherosclerosis (the hardening of arteries) and can also trigger heart attacks. Neurologically, carbon monoxide exposure reduces hand to eye coordination, vigilance, and continuous performance. It can also affect time discrimination.[15]
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
In 1758, Benjamin Franklin and John Hadley, a chemistry professor at Cambridge University, conducted an experiment to explore the principle of evaporation as a means to rapidly cool an object. Franklin and Hadley confirmed that evaporation of highly volatile liquids (such as alcohol and ether) could be used to drive down the temperature of an object past the freezing point of water. They conducted their experiment with the bulb of a mercury thermometer as their object and with a bellows used to speed up the evaporation. They lowered the temperature of the thermometer bulb down to −14 °C (7 °F) while the ambient temperature was 18 °C (64 °F). Franklin noted that, soon after they passed the freezing point of water 0 °C (32 °F), a thin film of ice formed on the surface of the thermometer's bulb and that the ice mass was about 6 mm (1⁄4 in) thick when they stopped the experiment upon reaching −14 °C (7 °F). Franklin concluded: "From this experiment one may see the possibility of freezing a man to death on a warm summer's day."[9]
×