My experience with Cody & Sons was an A+! I am always concerned with these companies taking advantage and charging more than they should. My technician, Mike, was on time, extremely professional and really knew his job. Prior to Cody & Sons, I had 5 other name brand HVAC companies service my furnace but no one could tell me why I smelled gas each time I turned my unit on. Several tried to sell me a new furnace. Mike thoroughly examined my unit and determined what the problem was. He then patiently explained it all to me in laymen's terms. I approved the work and Mike took care of it. I can't express the relief I feel knowing that my furnace is safe again and I am not inhaling fumes!!! From start to finish Mike took about an hour. The price I was charged was very fair! I am happy to say that I have finally found my go to HVAC company. THANK YOU, MIKE and Cody & Sons!!!

Our team of fully licensed and insured technicians each draw from between ten and thirty years of industry experience and share our unwavering dedication to customer service.  Entirely NATE-certified, our installation and service department has completed rigorous testing, and are exceptionally qualified to handle even the most complex HVAC challenges.  NATE (North American Technician Excellence) is the only nationwide certification program that is supported by the entire industry, and of all third-party certifications, has the lowest pass rate.


The last thing you need is for your air conditioning to stop working in the middle of a heat wave. If this has ever happened to you, you understand the need for a reliable company to come out and get the air conditioning going again. Let us prove to you that we are the right company for you in Southern Maryland. As a service we do offer maintenance of all air conditioning units to help prevent this problem, but we understand that things happen!
5) Check certifications. Many HVAC professionals belong to the Air Conditioning Contractors of America (ACCA) or the Sheet Metal and Air Conditioning Contractors’ National Association (SMACNA). Both sites provide listings of HVAC contractors by area. Look for contractors whose technicians are certified by North American Technician Excellence (NATE) and partnered with ENERGY STAR.
HVAC is an important part of residential structures such as single family homes, apartment buildings, hotels and senior living facilities, medium to large industrial and office buildings such as skyscrapers and hospitals, vehicles such as cars, trains, airplanes, ships and submarines, and in marine environments, where safe and healthy building conditions are regulated with respect to temperature and humidity, using fresh air from outdoors.
Dichlorodifluoromethane (R-12) was the most common blend used in automobiles in the U.S. until 1994, when most designs changed to R-134A due to the ozone-depleting potential of R-12. R-11 and R-12 are no longer manufactured in the U.S. for this type of application, so the only source for air-conditioning repair purposes is the cleaned and purified gas recovered from other air conditioner systems. Several non-ozone-depleting refrigerants have been developed as alternatives, including R-410A. It was first commercially used by Carrier Corp. under the brand name Puron.[citation needed]
CIBSE publishes several guides to HVAC design relevant to the UK market, and also the Republic of Ireland, Australia, New Zealand and Hong Kong. These guides include various recommended design criteria and standards, some of which are cited within the UK building regulations, and therefore form a legislative requirement for major building services works. The main guides are:
We happily offer all of our services in St Marys county. We view our neighbors in St. Mary’s county as important and valuable as our friends in Calvert. If you live in St Marys and you’re not sure if we can help you with your specific problem, please don’t hesitate to contact us and find out! We value all inquiries and our eager to help and assist our neighbors throughout all of Southern Maryland.
Our goal is to make you more comfortable in your home. When your furnace, central air conditioner, heat pump or boiler stops working and you need service, call the professionals at BGE HOME. Heating and cooling system breakdowns occur at the most inconvenient times, so rely on our certified, skilled technicians to make the repair quickly and correctly the first time.
Close all the windows in the house, turn off all the fans and exhaust fans, and shut off the furnace. Light some incense and walk slowly around the outer walls of the house. Anywhere you notice the smoke blowing away from something or being sucked toward something, there’s probably an air leak. Now that you’ve found it, seal it! Here’s how. Here are more ways to improve energy efficiency in your home.

The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
×