Nobody wants to deal with a broken furnace in winter. Lucky for you, our Denver furnace repair specialists are available 7 days a week. Don’t face cold winter nights without a well functioning furnace. Contact us, your Denver furnace repair company so that we can diagnose the problem and set you up with a preventative maintenance package so we can catch problems before they occur. Click HERE to learn more about our furnace related services.

You can usually slip the belt on the motor’s (smaller) pulley first and then start it on the blower pulley. Rotate the blower pulley by hand, holding the belt in place but keeping your fingers from getting caught between the belt and the pulley. The belt should slip right into place. If it seems to be too tight or difficult to set in place, it may be necessary to adjust the motor mount to provide more slack.
The performance of vapor compression refrigeration cycles[27] is limited by thermodynamics. These air conditioning and heat pump devices move heat rather than convert it from one form to another, so thermal efficiencies do not appropriately describe the performance of these devices. The Coefficient-of-Performance (COP) measures performance, but this dimensionless measure has not been adopted. Instead, the Energy Efficiency Ratio (EER) has traditionally been used to characterize the performance of many HVAC systems. EER is the Energy Efficiency Ratio based on a 35 °C (95 °F) outdoor temperature. To more accurately describe the performance of air conditioning equipment over a typical cooling season a modified version of the EER, the Seasonal Energy Efficiency Ratio (SEER), or in Europe the ESEER, is used. SEER ratings are based on seasonal temperature averages instead of a constant 35 °C (95 °F) outdoor temperature. The current industry minimum SEER rating is 14 SEER.[28]

The most recognized standards for HVAC design are based on ASHRAE data. The most general of four volumes of the ASHRAE Handbook is Fundamentals; it includes heating and cooling calculations. Each volume of the ASHRAE Handbook is updated every four years. The design professional must consult ASHRAE data for the standards of design and care as the typical building codes provide little to no information on HVAC design practices; codes such as the UMC and IMC do include much detail on installation requirements, however. Other useful reference materials include items from SMACNA, ACGIH, and technical trade journals.
Consequently, this water must exit the air handler—typically through plastic pipe or a drain tube. That drain tube goes directly outside, often terminating near the compressor, or to a floor drain or to a small electric “condensate pump” located by the air handler. Where a condensate pump is used, it connects to a 1/2-inch vinyl or rubber tube that exits outdoors or to a drain.
Designed to improve manufacturing process control in a printing plant, Carrier's invention controlled not only temperature but also humidity. Carrier used his knowledge of the heating of objects with steam and reversed the process. Instead of sending air through hot coils, he sent it through cold coils (filled with cold water). The air was cooled, and thereby the amount of moisture in the air could be controlled, which in turn made the humidity in the room controllable. The controlled temperature and humidity helped maintain consistent paper dimensions and ink alignment. Later, Carrier's technology was applied to increase productivity in the workplace, and The Carrier Air Conditioning Company of America was formed to meet rising demand. Over time, air conditioning came to be used to improve comfort in homes and automobiles as well. Residential sales expanded dramatically in the 1950s.[citation needed]
Recent Review: Metro Service was amazing. They came out on Saturday and secured the gas to a failing furnace to insure our safety. They came out on Monday and had the new furnace installed and operating within less than 4 hours. Polite, professional, meticulous and 35% lower than their competitors. I will be using them for all of my HVAC needs in the future.
A pinging or popping sound coming from the duct work can come from thermal expansion—the ductwork expanding and contracting as it heats and cools.  Or, air blowing past a loose flap of metal can make the sound. Track along the duct runs, listening for the sound. If you locate it, make a small dent in the sheet metal to provide a more rigid surface that’s less likely to move as it heats and cools.
If a heat exchanger cracks or contains holes, leaks can release carbon monoxide into your home. Carbon monoxide is nearly impossible for humans to detect on their own due to its characteristics of being colorless and odorless. Because of this, it is referred to as “The Silent Killer”. Some symptoms of carbon monoxide poisoning include headache, dizziness, fatigue, nausea and vomiting. It is extremely important to have a HVAC technician perform a furnace inspection annually to prevent problems such as carbon monoxide poisoning. UGI Heating, Cooling & Plumbing offers yearly maintenance packages and service agreements that include yearly maintenance and furnace inspections.
×