As a Carrier Factory Authorized Dealer, we are qualified in the most widely recognized and innovative selection of heating, cooling, and air quality options to satisfy any demand. From new installation and retrofit projects, to seasonal maintenance and repair, Modern Air Solutions optimizes the performance of equipment, targeting energy efficiency, reliability, and longevity.
Dichlorodifluoromethane (R-12) was the most common blend used in automobiles in the U.S. until 1994, when most designs changed to R-134A due to the ozone-depleting potential of R-12. R-11 and R-12 are no longer manufactured in the U.S. for this type of application, so the only source for air-conditioning repair purposes is the cleaned and purified gas recovered from other air conditioner systems. Several non-ozone-depleting refrigerants have been developed as alternatives, including R-410A. It was first commercially used by Carrier Corp. under the brand name Puron.[citation needed]
Air-source heat pumps are more popular in milder winter climates where the temperature is frequently in the range of 4–13 °C (40–55 °F), because heat pumps become inefficient in more extreme cold. This is because ice forms on the outdoor unit's heat exchanger coil, which blocks air flow over the coil. To compensate for this, the heat pump system must temporarily switch back into the regular air conditioning mode to switch the outdoor evaporator coil back to being the condenser coil, so that it can heat up and defrost. A heat pump system will therefore have a form of electric resistance heating in the indoor air path that is activated only in this mode in order to compensate for the temporary indoor air cooling, which would otherwise be uncomfortable in the winter.
Consequently, this water must exit the air handler—typically through plastic pipe or a drain tube. That drain tube goes directly outside, often terminating near the compressor, or to a floor drain or to a small electric “condensate pump” located by the air handler. Where a condensate pump is used, it connects to a 1/2-inch vinyl or rubber tube that exits outdoors or to a drain.
Air ducts come in two forms: cool air ducts (also known as “return ducts”) and warm air ducts (also known as “supply ducts”). Warm air from the furnace enters the home through the warm air registers. No more than 20: of these warm air ducts and registers should ever be closed off – this hinders air flow and could result in the overheating of the heat exchanger, causing costly damage to you home heating system.

Air flow meter Aquastat BACnet Blower door Building automation Carbon dioxide sensor Clean Air Delivery Rate (CADR) Gas sensor Home energy monitor Humidistat HVAC control system Intelligent buildings LonWorks Minimum efficiency reporting value (MERV) OpenTherm Programmable communicating thermostat Programmable thermostat Psychrometrics Room temperature Smart thermostat Thermostat Thermostatic radiator valve

James Harrison's first mechanical ice-making machine began operation in 1851 on the banks of the Barwon River at Rocky Point in Geelong, Australia. His first commercial ice-making machine followed in 1853, and his patent for an ether vapor compression refrigeration system was granted in 1855. This novel system used a compressor to force the refrigeration gas to pass through a condenser, where it cooled down and liquefied. The liquefied gas then circulated through the refrigeration coils and vaporized again, cooling down the surrounding system. The machine produced 3,000 kilograms (6,600 lb) of ice per day.[citation needed]
There was an unidentified beeping sound which I thought was coming from my indoor HVAC unit. The technician patiently spoke to me over the phone and we discovered that it was not the HVAC that was making the noise. The technician was extraordinarily helpful and polite as we spoke and he saved me a few hundred dollars since he helped me over the phone and didn't have to make an emergency visit. HVAC Unlimited is our "go to" company for all our heating and cooling needs!
High-efficiency condensing furnaces (90% AFUE and above) are a bit more complex than conventional furnaces. The main differences between a conventional and condensing furnace are the heat exchanger technology used to extract heat from the combustion process and the method used to exhaust the combustion gases. In these ways, the furnaces are very different. The condensing furnace does not have a significantly more efficient combustion process than does a conventional furnace; both use gas burners with electronic ignition. The difference lies in that the condensing furnace has a more efficient heat extraction process after combustion.
Turn off the gas supply valve, typically located by your gas meter on the gas inlet pipe. Turn off the gas by rotating the valve one quarter turn with an adjustable wrench. When the gas is off,  the valve’s oblong stem points perpendicular to the inlet pipe. Then call your gas utility or the fire department from a remote location. Do not return to your home until you know it is safe.
The HVAC industry is a worldwide enterprise, with roles including operation and maintenance, system design and construction, equipment manufacturing and sales, and in education and research. The HVAC industry was historically regulated by the manufacturers of HVAC equipment, but regulating and standards organizations such as HARDI, ASHRAE, SMACNA, ACCA, Uniform Mechanical Code, International Mechanical Code, and AMCA have been established to support the industry and encourage high standards and achievement.
Air conditioners can create a lot of water because they remove moisture from the air. To get rid of this, they have a [usually plastic] drain pipe that comes out of the side of the air handler. Over time, algae can block this pipe and, when it does, the AC won’t work. In fact, some condensate drains have a float switch that won’t let the AC run if water backs-up. Water can also puddle around the unit or flood the area. To deal with condensate problems, please see Air Conditioner Leaks Water, below.
We relocate frequently and one of the biggest hassles of relocating to new areas is finding reputable companies that send qualified technicians to perform work when you need it, whether for annual preventative maintenance or during a house emergency. We’ve been through the process several times and always dread researching and trying new companies. This was our first HVAC call here in northern Virginia. We are in new construction and chose not to use the builder’s sub-contractor for a technician call but looked through Carrier’s website for a local business. Jeremy Garner with HVAC Unlimited responded to our service request the morning following our call. I shadowed him performing work and he was patient while I peppered him with questions. He helped expand my HVAC knowledge in order to be a better property owner of our systems. He performed the work we thought was necessary, in a timely and professional manner, and gave us options for future annual maintenance. HVAC Unlimited is definitely on our list of go-to contractors.
When the time comes to schedule furnace repairs, you want a team you can trust. Keeping your home warm and comfortable is important for you and your family, which is why you should rely on the highly-trained team of technicians at Horizon Services. Our techs undergo at least 150 hours of technical training every year and are up-to-date on the latest, most advanced techniques in the trade. We also background-check all of our employees to ensure your complete comfort and safety. When you call on us for furnace repair, we will arrive on-time and on schedule, ready to resolve the issue as quickly as possible.
Most Michigan HVAC repair companies will often charge a “Travel Charge” or “Diagnosis Fee.” Randazzo calls this fee simply, a “Service Call Fee.” This will be the minimum cost of the repair. It is not recommended to judge a company on how expensive or how cheap their service rates are. In most cases, with larger companies the rates will be higher. This is not because they may have more overhead but simply because of the quality and preparedness of the service that will be preformed.
I was disappointed with the pressure of a tub and shower that were plumbed with 1/2 supply lines (2nd floor). Could be low pressure from the street, but I want to replace with 5/8. Plus, I'd like to have 2 back to back showers, one inside and one outside. So, I had intended to bring a 1 supply to both, then branch up to valves and shower head with 5/8. Finally, I thought pressure from the street was typically 55 to 70 psi and I am concerned if pvc can take that.Any thoughts?
In the UK, the Ozone Regulations[63] came into force in 2000 and banned the use of ozone depleting HCFC refrigerants such as R22 in new systems. The Regulation banned the use of R22 as a "top-up" fluid for maintenance between 2010 (for virgin fluid) and 2015 (for recycled fluid). This means that equipment that uses R22 can still operate, as long as it does not leak. Although R22 is now banned, units that use the refrigerant can still be serviced and maintained.
An annual inspection of your unit can ensure that the various potential problems mentioned above are detected early, and before they require complete replacement. During this inspection, for instance, a professional might find small cracks in your heat exchanger or a faulty seal in your blower motor. Some manufacturer's warranties even require these annual inspections to maintain validity. Typically, your furnace inspection will cost between $80 and $150 depending on the area in which you live and the professional you work with.
The most recognized standards for HVAC design are based on ASHRAE data. The most general of four volumes of the ASHRAE Handbook is Fundamentals; it includes heating and cooling calculations. Each volume of the ASHRAE Handbook is updated every four years. The design professional must consult ASHRAE data for the standards of design and care as the typical building codes provide little to no information on HVAC design practices; codes such as the UMC and IMC do include much detail on installation requirements, however. Other useful reference materials include items from SMACNA, ACGIH, and technical trade journals.
Vredevoogd Heating & Cooling Grand Rapids values each and every customer. Servicing or installing your HVAC system means establishing a service relationship with each homeowner. We promise to earn your trust with our consummate level of professionalism and expert service. We back our work with the strongest industry guarantees because we value your continued business.
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.

Reinstall the access panel and disconnect block. Turn on the circuit breaker and furnace switch. Then set the thermostat to a lower temperature and wait for the AC to start (see “Be Patient at Startup,” below). The compressor should run and the condenser fan should spin. If the compressor starts but the fan doesn’t, the fan motor is most likely shot. Shut off the power and remove the screws around the condenser cover. Lift the cover and remove the fan blade and motor (photo 7). Reinstall the blade and secure the cover. Then repower the unit and see if the fan starts. If it doesn’t, you’ve given it your best shot—it’s time to call a pro.

Aurora residents are well aware that when the furnace goes out in their home, can be incredibly frustrating to get working again. At times, there are serious things that go wrong with a home that needs to get fixed very quickly. As far as the furnace goes, it needs to get repaired or fixed as soon as possible, which is why it’s good to know that our furnace repair company does furnace replacement in Aurora and also Aurora furnace repair, is prepared to help at any time. To learn more about our furnace and heating services, click HERE today!


If you have forced-air cooling but there’s still a room that’s hotter than all the rest, a duct or vent booster fan can increase the flow of cool air into that room. Two types of booster fans are available. An in-line duct booster fan (shown) fits inside the duct of the room you’re trying to cool. You mount the fan near the outlet and it automatically kicks on when your cooling system runs.
Air flow meter Aquastat BACnet Blower door Building automation Carbon dioxide sensor Clean Air Delivery Rate (CADR) Gas sensor Home energy monitor Humidistat HVAC control system Intelligent buildings LonWorks Minimum efficiency reporting value (MERV) OpenTherm Programmable communicating thermostat Programmable thermostat Psychrometrics Room temperature Smart thermostat Thermostat Thermostatic radiator valve
×