Many disconnect blocks contain two cartridge fuses. Check them before you proceed with repairs (Photo 3). A blown fuse is a sign of a failing part inside the condensing unit. So don’t just replace it and think you’ve solved the problem. Instead, replace the parts we show here. Then install new fuses and fire up the unit. If it blows again, call a pro—you’ve got more serious issues.

Service Experts Heating and Air Conditioning was founded on the basis of providing customers with the best heating and cooling practices in the industry. Since its inception, Service Experts has been dedicated to community, providing the top of the line HVAC products and services in your area. If you want more information about your local HVAC leaders, call us at 866-397-3787 or set up an appointment with us online.


The cost to replace your gas furnace will vary based on the type and size of furnace you select, labor and installation costs, and any repairs your HVAC system may need. Nationally, average HVAC prices for a heating specialist range between $1,800 and $2,500. It’s important to select the right size gas furnace for your heating needs. A furnace that’s too small won’t heat your house properly, while a furnace that’s too large will run inefficiently, cycling on and off and likely breaking down sooner. HVAC specialists calculate your exact heat needs by measuring your home and incorporating variables such as the regional climate and your home’s level of insulation. Retail pricing for gas furnaces can range from $650 up to $3,000 and more. The higher the AFUE (annual fuel utilization efficiency) rating of the furnace, the more efficient it is at turning fuel into heat and the lower your carbon footprint and utility bill will be. HVAC installation costs are often based on an hourly rate and can range from under $50 to over $100 per hour, depending on the company and the furnace being installed. Higher-end furnaces cost more to install because they require added labor and expertise. For a typical installation, it might take two HVAC installation pros one day or less to remove your old furnace and replace it with a new one.
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
Gainesville Mechanical Inc is open for regular business hours, Monday through Friday, from 8 a.m. to 5 p.m. We offer everyday extended business hours, at regular rates, to meet the challenge of your busy schedule with flexible appointment times, and always have a licensed technician at your door within 24 hours.  For desperate times, we protect your home, comfort, and safety with 24/7 Emergency Assistance without added after-hour costs.  Contact us at 770-532-9130, and rest assured, we prioritize your best interests.  Our skilled service never comes with inflated or hidden charges.  We provide affordable rates, upfront pricing, and the detailed information you need to make the best possible decisions.  We service all makes and models of cooling equipment, optimizing safety, efficiency, and reliability, to deliver superior, ongoing performance.  Trust our award-winning team of NATE-certified technicians to restore your comfort today, with repairs that ensure long-term satisfaction.

In 1906, Stuart W. Cramer of Charlotte was exploring ways to add moisture to the air in his textile mill. Cramer coined the term "air conditioning", using it in a patent claim he filed that year as an analogue to "water conditioning", then a well-known process for making textiles easier to process. He combined moisture with ventilation to "condition" and change the air in the factories, controlling the humidity so necessary in textile plants. Willis Carrier adopted the term and incorporated it into the name of his company.[10]
CIBSE publishes several guides to HVAC design relevant to the UK market, and also the Republic of Ireland, Australia, New Zealand and Hong Kong. These guides include various recommended design criteria and standards, some of which are cited within the UK building regulations, and therefore form a legislative requirement for major building services works. The main guides are:
Our tenant called at 8:00 pm on a Friday night to say the air conditioner was not working. We placed a call to Gator and immediately received a call from the tech asking for tenant's name and contact information. He called back after visiting the sight to say he got the system working again but recommended we install a new unit. My husband met with Carlos a few days later and scheduled installation for the following week. Carlos met with my husband again after the installation to go over the details of the new unit and to ensure he was satisfied with the job. The installers Brandon Hayword and Christian Winslow not only did a top-notch job, but they left the work site exactly how they found it. From start to finish, my husband and I were impressed by the level of professionalism exhibited by all of Gator's employees. We decided Gator is our new HVAC company.
Some systems include an "economizer mode", which is sometimes called a "free-cooling mode". When economizing, the control system will open (fully or partially) the outside air damper and close (fully or partially) the return air damper. This will cause fresh, outside air to be supplied to the system. When the outside air is cooler than the demanded cool air, this will allow the demand to be met without using the mechanical supply of cooling (typically chilled water or a direct expansion "DX" unit), thus saving energy. The control system can compare the temperature of the outside air vs. return air, or it can compare the enthalpy of the air, as is frequently done in climates where humidity is more of an issue. In both cases, the outside air must be less energetic than the return air for the system to enter the economizer mode.
Many homeowners don't often think of the state of their furnace—that is until, the first cold day of the year comes around and the furnace won't turn on or only blows cold air. Keeping an eye out for common signs of trouble can help you avoid a complete furnace breakdown. Addressing any issues early on can also help you avoid most extensive (and therefore, more expensive) repairs down the road.
You can usually slip the belt on the motor’s (smaller) pulley first and then start it on the blower pulley. Rotate the blower pulley by hand, holding the belt in place but keeping your fingers from getting caught between the belt and the pulley. The belt should slip right into place. If it seems to be too tight or difficult to set in place, it may be necessary to adjust the motor mount to provide more slack.
Before selecting the installation location of air conditioner, several main factors need to be considered. First of all, the direction of air flow from the indoor units should not fall on the place of rest or work area. Secondly, there should not be any obstacles on the way of the airflow that might prevent it from covering the space of the premises as much as possible. The outdoor unit must also be located in an open space, otherwise the heat from the house will not be effectively discharged outside and the productivity of the entire system will drop sharply. It is highly advisable to install the air conditioner units in easily accessible places, for further maintenance during operation.
I was disappointed with the pressure of a tub and shower that were plumbed with 1/2 supply lines (2nd floor). Could be low pressure from the street, but I want to replace with 5/8. Plus, I'd like to have 2 back to back showers, one inside and one outside. So, I had intended to bring a 1 supply to both, then branch up to valves and shower head with 5/8. Finally, I thought pressure from the street was typically 55 to 70 psi and I am concerned if pvc can take that.Any thoughts?
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
The liquid refrigerant is returned to another heat exchanger where it is allowed to evaporate, hence the heat exchanger is often called an evaporating coil or evaporator. As the liquid refrigerant evaporates it absorbs energy (heat) from the inside air, returns to the compressor, and repeats the cycle. In the process, heat is absorbed from indoors and transferred outdoors, resulting in cooling of the building.
In hot weather, air conditioning can prevent heat stroke, dehydration from excessive sweating and other problems related to hyperthermia. Heat waves are the most lethal type of weather phenomenon in developed countries. Air conditioning (including filtration, humidification, cooling and disinfection) can be used to provide a clean, safe, hypoallergenic atmosphere in hospital operating rooms and other environments where proper atmosphere is critical to patient safety and well-being. It is sometimes recommended for home use by people with allergies.
×