If your compressor doesn’t have an overload button and you hear it humming or buzzing, poke a screwdriver or stick down through the top grille and try to spin the fan blades clockwise. If doing this gives the fan enough of a boost to get it going, the unit has a faulty capacitor that must be replaced. See How to Test and Replace an AC Run Capacitor, above.
Whole-house fans have helped cool homes for a century. The basic design is simple: An attic-mounted fan pushes hot air out through attic vents and draws cooler, outside air in through open doors and windows. This rapid air exchange—large fans can purge a house of hot air in two to three minutes—not only removes built-up heat but also creates a pleasant breeze.
Dichlorodifluoromethane (R-12) was the most common blend used in automobiles in the U.S. until 1994, when most designs changed to R-134A due to the ozone-depleting potential of R-12. R-11 and R-12 are no longer manufactured in the U.S. for this type of application, so the only source for air-conditioning repair purposes is the cleaned and purified gas recovered from other air conditioner systems. Several non-ozone-depleting refrigerants have been developed as alternatives, including R-410A. It was first commercially used by Carrier Corp. under the brand name Puron.[citation needed]
A number of other variables can influence your decision on whether to repair or replace your furnace, as well. In addition to cost and brand, consider the expected lifetime of your furnace. If it is more than 15 years old, it might make more sense to invest in a new unit even if it costs more than simply repairing the current problem. Long-term costs also play into the equation. For example, your new furnace may be more energy efficient than the current unit. Even though you will pay more for the actual installation, you might be able to make back your investment through lower energy bills. To make your decision, consult with a reliable professional on what to do. In inspecting your furnace, they will be able to make an informed recommendation that looks not just to the next year, but years into the future. That way, you can make the best possible decision for your home and budget long-term.

If your furnace is more than 15 years old or broken beyond repair, furnace replacement is necessary. Old furnaces are very inefficient which means that you could be spending more on your gas or electric bill than you need to. Old furnaces can also be very hazardous to your health and home. Furnaces are basically controlled fires, and when the control systems on your furnace are out of date or malfunctioning, the safety of your home is in jeopardy. If you have an old or malfunctioning furnace, or if you want a safety check on your current system, then give our furnace replacement company a call today!


American design standards are legislated in the Uniform Mechanical Code or International Mechanical Code. In certain states, counties, or cities, either of these codes may be adopted and amended via various legislative processes. These codes are updated and published by the International Association of Plumbing and Mechanical Officials (IAPMO) or the International Code Council (ICC) respectively, on a 3-year code development cycle. Typically, local building permit departments are charged with enforcement of these standards on private and certain public properties.
HVAC professionals in the US can receive training through formal training institutions, where most earn associate degrees. Training for HVAC technicians includes classroom lectures and hands-on tasks, and can be followed by an apprenticeship wherein the recent graduate works alongside a professional HVAC technician for a temporary period.[34] HVAC techs who have been trained can also be certified in areas such as air conditioning, heat pumps, gas heating, and commercial refrigeration.[35]
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
×