Most central air conditioners have two basic parts: an outdoor unit (compressor/condenser) that sits next to your home and an indoor unit (evaporator) that’s located in a central duct near your furnace. If you have a heat pump instead of a furnace, the indoor unit will be in the air handler. Use the same maintenance steps we show here. If your furnace looks different from the one shown or you have a heat pump, use the owner’s manual to find your way around it. The basic parts will be the same. Check out our step-by-step guide for deep-cleaning your home air conditioner.
Most central air conditioners are connected to a home's forced-air distribution system. Thus, the same motor, blower, and ductwork used for heating are used to distribute cool air from the air conditioning system. When a central air conditioner is operating, hot air inside the house flows to the furnace through the return-air duct. The hot air is moved by the blower across the cooled evaporator coil in the plenum and is then delivered through ducts to cool the house. When the air conditioner works but the house doesn't cool, the problem is probably in the distribution system.
At Aire Serv, we’re on call 24/7 to offer air conditioner repair when you need it most. We charge by the job, not by the hour, and there’s never an overtime charge. We explain all your options before starting repairs so you can decide what’s best for you. Our air conditioner repair experts are licensed and insured, and we guarantee our work the first time around. Since we service and repair all equipment brands, you can put your full confidence in us to professionally complete your AC repair.
There was an unidentified beeping sound which I thought was coming from my indoor HVAC unit. The technician patiently spoke to me over the phone and we discovered that it was not the HVAC that was making the noise. The technician was extraordinarily helpful and polite as we spoke and he saved me a few hundred dollars since he helped me over the phone and didn't have to make an emergency visit. HVAC Unlimited is our "go to" company for all our heating and cooling needs!
The HVAC industry is a worldwide enterprise, with roles including operation and maintenance, system design and construction, equipment manufacturing and sales, and in education and research. The HVAC industry was historically regulated by the manufacturers of HVAC equipment, but regulating and standards organizations such as HARDI, ASHRAE, SMACNA, ACCA, Uniform Mechanical Code, International Mechanical Code, and AMCA have been established to support the industry and encourage high standards and achievement.
The selection of indoor units has one restriction: their total power should not exceed the capacity of the outdoor unit. In practice, however, it is very common to see a multi-split system with a total capacity of indoor units greater than the outdoor capacity by at least 20%. However, it is wrong to expect better performance when all indoor units are turned on at the same time, since the total capacity of the whole system is limited by the capacity of the outdoor unit. Simply put, the outdoor unit will distribute all its power to all operating indoor units in such a way that some of the rooms may not have a very comfortable temperature level. However, the calculation of the total power is not simple, since it takes into account not only the nominal power of the units, but also the cooling capacity, heating, dehumidification, humidification, venting, etc.
Has another company told you that your furnace has a cracked heat exchanger?  The heat exchanger is the heart of your furnace. Its failure can result in a dangerous situation for your home and the best solution is usually a new furnace.  Because of these issues, Bonney takes this situation very seriously.  We will offer you proof of the cracked heat exchanger in the form of a picture from our video inspection camera or a report from our exhaust gas analyzer, before we make our recommendation.
In variable climates, the system may include a reversing valve that switches from heating in winter to cooling in summer. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa. This allows a facility to be heated and cooled by a single piece of equipment by the same means, and with the same hardware.
Here at Brothers Plumbing, Heating, and Electric, we have a Home Care Club that provides members with many benefits. These benefits include: 2 year warranty on all work (drain work is excluded), transferable club membership, no “show up” fees, priority service, 10% discount on repairs, quarterly newsletters, carefree scheduling (we will contact you and remind you when you need service), 2 free furnace/air conditioner filter changes, exclusive coupons, quarterly drawings, 4 on-going safety checks, and a 100% satisfaction guarantee. So if you’d like to join our Home Care Club, then give us a call or click here today.
To keep your furnace in good working order it’s important to have it regularly cleaned. The national average furnace cleaning cost ranges from $60 to $80, though prices can vary greatly based on where you live in the country and what your furnace maintenance includes. An HVAC company may have different rates for different levels of furnace maintenance. For example,one company may offer general furnace maintenance for $79 and advanced maintenance for $138. Another company may offer a 38-point maintenance check for $89 and a 64-point maintenance check for $178. According to Energy.gov, a standard furnace cleaning and maintenance visit can include:
Any concern with your cooling system, however minor, is worth checking out.  NATE-certified technicians can quickly identify the problem and prevent more extensive and costly damage.  Catching defects quickly is the key to cost-effective repairs.  Elevated operational noise such as grinding, screeching, or wheezing is more than aggravating.  Think of those sounds as warning bells.  They’re an indication of component failure.  Listen to what they’re telling you and call for professional assistance.  Worn or misaligned belts are easily repaired.  Strange smells from contaminants such as mold or mildew are best handled before allergens enter breathing air, diminish airflow, and block the coil.  Temperature swings, unstable humidity, or extended run times are all signs of bigger problems on the way.  Call Ferran Services at 407-422-3551 (Orlando) or 386-322-6168 (Volusia), and our licensed technicians will perform a complete system check, ensuring safe, efficient and reliable operation.
Air ducts come in two forms: cool air ducts (also known as “return ducts”) and warm air ducts (also known as “supply ducts”). Warm air from the furnace enters the home through the warm air registers. No more than 20: of these warm air ducts and registers should ever be closed off – this hinders air flow and could result in the overheating of the heat exchanger, causing costly damage to you home heating system.
The use of CFC as a refrigerant was once common, including the refrigerants R-11 and R-12 (sold under the brand name Freon-12). Freon refrigerants were commonly used during the 20th century in air conditioners due to their superior stability and safety properties. When they are released accidentally or deliberately, these chlorine-bearing refrigerants eventually reach the upper atmosphere.[61] Once the refrigerant reaches the stratosphere, UV radiation from the Sun homolytically cleaves the chlorine-carbon bond, yielding a chlorine radical. These chlorine radicals catalyze the breakdown of ozone into diatomic oxygen, depleting the ozone layer that shields the Earth's surface from strong UV radiation. Each chlorine radical remains active as a catalyst until it binds with another radical, forming a stable molecule and quenching the chain reaction.
Whether it’s a sticky day in July and you need an AC repair, or your employees are having trouble breathing because of stagnant indoor air, you can rely on HI-VAC Air Conditioning Service to quickly resolve your problem. We are the go-to source for air conditioning services in Plantation, Miramar, Pembroke Pines, Weston, Coral Springs, Sunrise, FL and the surrounding area. Give us a call today to learn how we can improve your indoor comfort.
Natural ventilation is the ventilation of a building with outside air without using fans or other mechanical systems. It can be via operable windows, louvers, or trickle vents when spaces are small and the architecture permits. In more complex schemes, warm air is allowed to rise and flow out high building openings to the outside (stack effect), causing cool outside air to be drawn into low building openings. Natural ventilation schemes can use very little energy, but care must be taken to ensure comfort. In warm or humid climates, maintaining thermal comfort solely via natural ventilation might not be possible. Air conditioning systems are used, either as backups or supplements. Air-side economizers also use outside air to condition spaces, but do so using fans, ducts, dampers, and control systems to introduce and distribute cool outdoor air when appropriate.
Refrigeration air conditioning equipment usually reduces the absolute humidity of the air processed by the system. The relatively cold (below the dewpoint) evaporator coil condenses water vapor from the processed air, much like an ice-cold drink will condense water on the outside of a glass. Therefore, water vapor is removed from the cooled air and the relative humidity in the room is lowered. The water is usually sent to a drain or may simply drip onto the ground outdoors. The heat is ejected by the air conditioners condenser, which is located outside of the area being cooled.
The selection of indoor units has one restriction: their total power should not exceed the capacity of the outdoor unit. In practice, however, it is very common to see a multi-split system with a total capacity of indoor units greater than the outdoor capacity by at least 20%. However, it is wrong to expect better performance when all indoor units are turned on at the same time, since the total capacity of the whole system is limited by the capacity of the outdoor unit. Simply put, the outdoor unit will distribute all its power to all operating indoor units in such a way that some of the rooms may not have a very comfortable temperature level. However, the calculation of the total power is not simple, since it takes into account not only the nominal power of the units, but also the cooling capacity, heating, dehumidification, humidification, venting, etc.

If you need fast and reliable furnace repairs in Denver, then contact Brothers Plumbing, Heating and Electric. If your house feels colder than you think it should, it could be because your heating system is malfunctioning. When you give us a call, a Denver furnace repair expert will be able to help right away and give you a complete diagnosis of any problems. We will always attempt to fix your furnace before considering a replacement. If your furnace cannot be repaired, though our Denver furnace replacement experts are happy to discuss your options with you including modern energy efficient models.

The contactor (relay) and start/run capacitor(s) (see illustration below) fail most often and are inexpensive. So it’s a safe bet to buy and install those parts right away, especially if your air conditioning service unit is older than five years. The condenser fan motor can also fail, but it runs about $150 — hold off buying that unless you’re sure that’s the culprit.
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
×