A dehumidifier is an air-conditioner-like device that controls the humidity of a room or building. It is often employed in basements which have a higher relative humidity because of their lower temperature (and propensity for damp floors and walls). In food retailing establishments, large open chiller cabinets are highly effective at dehumidifying the internal air. Conversely, a humidifier increases the humidity of a building.
Your HVAC professional can perform a yearly tune-up of your system for around $80-$100. This yearly maintenance can go far toward heading off major repairs to your system and provide you with peace of mind and considerable savings in the long term. Additionally, regular servicing of your AC unit can help a home inspector to certify that your unit is working properly in the event you decide to sell your home.
Air ducts come in two forms: cool air ducts (also known as “return ducts”) and warm air ducts (also known as “supply ducts”). Warm air from the furnace enters the home through the warm air registers. No more than 20: of these warm air ducts and registers should ever be closed off – this hinders air flow and could result in the overheating of the heat exchanger, causing costly damage to you home heating system.
My experience with Cody & Sons was an A+! I am always concerned with these companies taking advantage and charging more than they should. My technician, Mike, was on time, extremely professional and really knew his job. Prior to Cody & Sons, I had 5 other name brand HVAC companies service my furnace but no one could tell me why I smelled gas each time I turned my unit on. Several tried to sell me a new furnace. Mike thoroughly examined my unit and determined what the problem was. He then patiently explained it all to me in laymen's terms. I approved the work and Mike took care of it. I can't express the relief I feel knowing that my furnace is safe again and I am not inhaling fumes!!! From start to finish Mike took about an hour. The price I was charged was very fair! I am happy to say that I have finally found my go to HVAC company. THANK YOU, MIKE and Cody & Sons!!!
A specialized air conditioner that is used only for dehumidifying is called a dehumidifier. It also uses a refrigeration cycle, but differs from a standard air conditioner in that both the evaporator and the condenser are placed in the same air path. A standard air conditioner transfers heat energy out of the room because its condenser coil releases heat outside. However, since all components of the dehumidifier are in the same room, no heat energy is removed. Instead, the electric power consumed by the dehumidifier remains in the room as heat, so the room is actually heated, just as by an electric heater that draws the same amount of power.
Many heating and air conditioning companies are only interested in selling you equipment and service agreements. We’re interested in doing what’s best for our customers and in building and maintaining life-long relationships. With more than 55 years of service to the Tulsa, Oklahoma area, you can rest assured that our reputation and longevity speak for itself. We are easy to do business with!

A multi-split system[44] is a conventional split system, which is divided into two parts (evaporator and condenser) and allows cooling or heating of several rooms with one external unit. In the outdoor unit of this air conditioner there is a more powerful compressor, ports for connecting several traces and automation with locking valves for regulating the volume of refrigerant supplied to the indoor units located in the room.


If your AC doesn’t turn off when room temperature reaches the temperature set on the thermostat, the problem is generally occurring either at the thermostat or in the electrical system that runs the outside condensing unit. You can use the AC’s circuit breaker to shut off the unit, but that should not be a permanent solution—circuit breakers are not designed to be used like light switches.
Air-source heat pumps are more popular in milder winter climates where the temperature is frequently in the range of 4–13 °C (40–55 °F), because heat pumps become inefficient in more extreme cold. This is because ice forms on the outdoor unit's heat exchanger coil, which blocks air flow over the coil. To compensate for this, the heat pump system must temporarily switch back into the regular air conditioning mode to switch the outdoor evaporator coil back to being the condenser coil, so that it can heat up and defrost. A heat pump system will therefore have a form of electric resistance heating in the indoor air path that is activated only in this mode in order to compensate for the temporary indoor air cooling, which would otherwise be uncomfortable in the winter.
In the United States, HVAC engineers generally are members of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), EPA Universal CFC certified (for installation and service of CFC HVAC devices), or locally engineer certified such as a Special to Chief Boilers License issued by the state or, in some jurisdictions, the city. ASHRAE is an international technical society for all individuals and organizations interested in HVAC. The Society, organized into regions, chapters, and student branches, allows exchange of HVAC knowledge and experiences for the benefit of the field's practitioners and the public. ASHRAE provides many opportunities to participate in the development of new knowledge via, for example, research and its many technical committees. These committees typically meet twice per year at the ASHRAE Annual and Winter Meetings. A popular product show, the AHR Expo, is held in conjunction with each winter meeting. The Society has approximately 50,000 members and has headquarters in Atlanta, Georgia.
If your furnace needs to be repaired, you’ll want to find a qualified heating, ventilating and air conditioning (HVAC) repair technician. Each state has its own licensing requirements; some require all HVAC technicians to have an HVAC license, while others only require someone operating an HVAC service and installation company with employees to hold a contractor’s license. For example, in Alabama, the Alabama Board of Heating Air Conditioning, and Refrigeration Contractors regulates licensing, while in Kansas there is no state regulatory body and HVAC licensing can vary by region. For simple furnace repairs like changing out a filter, a trusted handyman can probably handle the job, but a trained professional should be hired for tasks like replacing a gas valve, installing a new inducer fan motor or other critical furnace repair jobs that involve dealing with gas leaks or other dangerous conditions. For more, check out our tips for smart hiring on Thumbtack.

We contacted GatorAC and have been pleased through the entire process of the purchase, installation and the daily functioning of the unit. We spoke to Angie to get information about the Trane AC. She arranged for Carlos Garcia to come to the house to determine the unit that would fit our needs. We made the choice between 3 units on Thursday and the unit was installed Friday. The Installation team, Willie Shaw and Gary Barber were the best. When they left everything was done, clean and clear and working great. We would recommend GatorAC for your AC needs.


Business Description: For many years our name has been synonymous with First-Rate, Top Quality HVAC services in the DFW area. Our product range has grown to meet today’s ever-changing demands, all the while continuously adopting the latest energy efficient technology. We offer both Installation & Service for air conditioning and heating systems. Quality maintenance is just as important as quality materials when it comes to extending the life and performance of your Heat and A/C units. Free Service with Repair or $39.95 for residential ground units.
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
×