2) Keep your coils clean. The AC coils and fins on the outside of your unit need to be kept clean and clear of obstructions. Leaves and other debris sometimes accumulate around your unit. If obstructions are present, your unit must work harder to function than it should. You can clean your unit with a regular garden hose and a broom. Do not use a pressure washer, as the strong spray could cause harm to your system. A little bit of housekeeping in this regard goes far toward keeping your air conditioner working optimally. 
A heat pump is an air conditioner in which the refrigeration cycle can be reversed, producing heating instead of cooling in the indoor environment. They are also commonly referred to as a "reverse cycle air conditioner". The heat pump is significantly more energy efficient than electric resistance heating. Some homeowners elect to have a heat pump system installed as a feature of a central air conditioner. When the heat pump is in heating mode, the indoor evaporator coil switches roles and becomes the condenser coil, producing heat. The outdoor condenser unit also switches roles to serve as the evaporator, and discharges cold air (colder than the ambient outdoor air).
SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
Get an accurate price for your HVAC repair costs by contacting a local heating and cooling company and scheduling an inspection. Search HVAC.com’s Contractor Directory to find local HVAC contractors who perform heating and cooling repairs. Call for service and find the price of the HVAC repair costs needed to get your system back into good working order!

The fan limit switch controls the furnace blower. The fan limit switch has three settings: “Fan On”, “Fan Off”, and “Limit”. In the “Fan Off” setting, the blower will only operate if there is warm air in the plenum to prevent cool air from blowing into the home. The “Fan On” setting will keep the blower operating even after the burner has shutdown, making sure that all of the hot air produced is circulated. The “Limit” setting is a safety control that will turn the burner off in the rare event that the air in the warm air plenum reaches an unsafe temperature. This may be the case if ducts are blocked or if the system controls are malfunctioning.


Bonney’s NATE certified technicians will troubleshoot and repair your furnace for safe and reliable operation. Our technicians use state of the art tools including video inspection cameras and exhaust gas analyzers to perform thorough, comprehensive diagnostics when equipment is broken. Furthermore, we arrive in a “warehouse on wheels” stocked with many parts to get your furnace repaired as quickly as possible.  For an unexpected heater repair Bonney offers financing to make your comfort affordable.
Without proper ventilation, carbon monoxide can be lethal at concentrations of 1000 ppm (0.1%). However, at several hundred ppm, carbon monoxide exposure induces headaches, fatigue, nausea, and vomiting. Carbon monoxide binds with hemoglobin in the blood, forming carboxyhemoglobin, reducing the blood's ability to transport oxygen. The primary health concerns associated with carbon monoxide exposure are its cardiovascular and neurobehavioral effects. Carbon monoxide can cause atherosclerosis (the hardening of arteries) and can also trigger heart attacks. Neurologically, carbon monoxide exposure reduces hand to eye coordination, vigilance, and continuous performance. It can also affect time discrimination.[15]
First, it is wise to stick with a company that specializes in HVAC services. While many general handyman companies may do some things with AC units, a company that specializes in air conditioning and heating is always a better option. Because air conditioning repairs can be quite costly, depending on the particular problem, it is best to work with highly trained HVAC professionals to ensure quality work.
CIBSE publishes several guides to HVAC design relevant to the UK market, and also the Republic of Ireland, Australia, New Zealand and Hong Kong. These guides include various recommended design criteria and standards, some of which are cited within the UK building regulations, and therefore form a legislative requirement for major building services works. The main guides are:

If a heat exchanger cracks or contains holes, leaks can release carbon monoxide into your home. Carbon monoxide is nearly impossible for humans to detect on their own due to its characteristics of being colorless and odorless. Because of this, it is referred to as “The Silent Killer”. Some symptoms of carbon monoxide poisoning include headache, dizziness, fatigue, nausea and vomiting. It is extremely important to have a HVAC technician perform a furnace inspection annually to prevent problems such as carbon monoxide poisoning. UGI Heating, Cooling & Plumbing offers yearly maintenance packages and service agreements that include yearly maintenance and furnace inspections.
ISO 16813:2006 is one of the ISO building environment standards.[32] It establishes the general principles of building environment design. It takes into account the need to provide a healthy indoor environment for the occupants as well as the need to protect the environment for future generations and promote collaboration among the various parties involved in building environmental design for sustainability. ISO16813 is applicable to new construction and the retrofit of existing buildings.[33]
We understand having problems with your air conditioning system - can be frustrating and uncomfortable. That's why Gator Air Conditioning only employs background checked, drug tested, highly trained and certified technicians. And we are so confident in their skill to correctly diagnosis and complete your Air Conditioner repair that we cover them with our Fixed Right Guarantee. Our Comfort Advisors come from the industry with the technical expertise needed to ensure the air conditioning systems we quote will be sized right to maximize performance. We employ the best air conditioner installers in Bradenton, FL to ensure your air conditioning system will be installed right to meet or exceed manufacturer recommendations. For your peace of mind, our Installation Guarantees cover more than just the equipment… we also cover your money, time, our workmanship, and your satisfaction.
This job involves removing the access panel, loosening a couple of bolts that hold the blower motor at the proper tension, and adjusting its distance or realigning the belt. In many cases, it’s a good idea to remove the belt and buy a replacement at a home center. Last, when reinstalling the belt, be careful not to over-tighten it; this can wear out the motor bearings.
An annual inspection of your unit can ensure that the various potential problems mentioned above are detected early, and before they require complete replacement. During this inspection, for instance, a professional might find small cracks in your heat exchanger or a faulty seal in your blower motor. Some manufacturer's warranties even require these annual inspections to maintain validity. Typically, your furnace inspection will cost between $80 and $150 depending on the area in which you live and the professional you work with.
If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.

The use of furnaces, space heaters, and boilers as a method of indoor heating could result in incomplete combustion and the emission of carbon monoxide, nitrogen oxides, formaldehyde, volatile organic compounds, and other combustion byproducts. Incomplete combustion occurs when there is insufficient oxygen; the inputs are fuels containing various contaminants and the outputs are harmful byproducts, most dangerously carbon monoxide, which is a tasteless and odorless gas with serious adverse health effects.[14]
As a Carrier Factory Authorized Dealer, M and M, Heating & Cooling, Plumbing & Electrical is qualified to properly size and install the most technologically advanced and well-regarded heating, cooling, and air quality products on the market today. Our team is NATE-certified, factory trained, EPA certified, and regularly updated, ensuring the right solution to any challenge.
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
×