Air ducts come in two forms: cool air ducts (also known as “return ducts”) and warm air ducts (also known as “supply ducts”). Warm air from the furnace enters the home through the warm air registers. No more than 20: of these warm air ducts and registers should ever be closed off – this hinders air flow and could result in the overheating of the heat exchanger, causing costly damage to you home heating system.

An alternative to packaged systems is the use of separate indoor and outdoor coils in split systems. Split systems are preferred and widely used worldwide except in North America. In North America, split systems are most often seen in residential applications, but they are gaining popularity in small commercial buildings. The split systems are a great choice for small buildings where ductwork is not feasible or where the space conditioning efficiency is of prime concern [21]. The benefits of ductless air conditioning systems include easy installation, no ductwork, greater zonal control, flexibility of control and quiet operation [22]. In space conditioning, the duct losses can account for 30% of energy consumption [23]. The use of minisplit can result in energy savings in space conditioning as there are no losses associated with ducting.
AC air handler squealing or grinding noises. Though most air handlers have direct-drive motors, some older units may be belt-driven. Squealing sounds from a belt-drive air handler generally occur when the belt that connects the motor to the blower slips. In most cases, the belt is improperly aligned or worn and needs replacement. Follow the instructions above under Air Conditioner Not Blowing Air and refer to your owner’s manual.
In the case of heated water or steam, piping is used to transport the heat to the rooms. Most modern hot water boiler heating systems have a circulator, which is a pump, to move hot water through the distribution system (as opposed to older gravity-fed systems). The heat can be transferred to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be mounted on walls or installed within the floor to produce floor heat.

Designed to improve manufacturing process control in a printing plant, Carrier's invention controlled not only temperature but also humidity. Carrier used his knowledge of the heating of objects with steam and reversed the process. Instead of sending air through hot coils, he sent it through cold coils (filled with cold water). The air was cooled, and thereby the amount of moisture in the air could be controlled, which in turn made the humidity in the room controllable. The controlled temperature and humidity helped maintain consistent paper dimensions and ink alignment. Later, Carrier's technology was applied to increase productivity in the workplace, and The Carrier Air Conditioning Company of America was formed to meet rising demand. Over time, air conditioning came to be used to improve comfort in homes and automobiles as well. Residential sales expanded dramatically in the 1950s.[citation needed]

Whether it’s a sticky day in July and you need an AC repair, or your employees are having trouble breathing because of stagnant indoor air, you can rely on HI-VAC Air Conditioning Service to quickly resolve your problem. We are the go-to source for air conditioning services in Plantation, Miramar, Pembroke Pines, Weston, Coral Springs, Sunrise, FL and the surrounding area. Give us a call today to learn how we can improve your indoor comfort.

At Genz-Ryan, we are here for you 24 hours a day, 7 days a week so you can count on us for all your heating repair work in the Minneapolis area. Our furnace repair technicians are well-trained and experienced. They’re ready to take care of any heating issue that you may have. We are a Lennox Premier Furnace Dealer and provide expert furnace repair service for most of the Minneapolis/St. Paul area. For over 60 years we have been getting the job done right the first time.
Before opening the electrical cover on the A/C unit, be sure to shut off all power to the compressor unit and the indoor furnace or air handler, and verify that it is off. Note that this may mean shutting off a circuit breaker that serves the furnace and air handler, and then, near the compressor, pulling out the disconnect block (or shutting off the 220-volt power) to the outdoor compressor.
×