For residential homes, some countries set minimum requirements for energy efficiency. In the United States, the efficiency of air conditioners is often (but not always) rated by the seasonal energy efficiency ratio (SEER). The higher the SEER rating, the more energy efficient is the air conditioner. The SEER rating is the BTU of cooling output during its normal annual usage divided by the total electric energy input in watt hours (W·h) during the same period.[33]
With the split system, the evaporator coil is connected to a remote condenser unit using refrigerant piping between an indoor and outdoor unit instead of ducting air directly from the outdoor unit. Indoor units with directional vents mount onto walls, suspended from ceilings, or fit into the ceiling. Other indoor units mount inside the ceiling cavity, so that short lengths of duct handle air from the indoor unit to vents or diffusers around the rooms.

Evaporative coolers tend to feel as if they are not working during times of high humidity, when there is not much dry air with which the coolers can work to make the air as cool as possible for dwelling occupants. Unlike other types of air conditioners, evaporative coolers rely on the outside air to be channeled through cooler pads that cool the air before it reaches the inside of a house through its air duct system; this cooled outside air must be allowed to push the warmer air within the house out through an exhaust opening such as an open door or window.[28] These coolers cost less and are mechanically simple to understand and maintain.
Any forced air system in your home - whether it is powered through electric or gas-generated energy - requires a blower motor. This component consists of an electric motor and fan, and is responsible for pushing air evenly through the furnace. As hvac.com points out, you can easily identify the blower motor in your furnace as the part that looks similar to a hamster wheel at the bottom of the unit. If it stops working, the air needed to heat your home will no longer be pushed through the furnace to be heated and distributed evenly. In that case, you need to inquire about potential repairs. Blower motor repair typically costs between $150 for a simple fix, and $450 for complete replacement and installation of the part. Where you land on that range depends on the exact damage.
With the split system, the evaporator coil is connected to a remote condenser unit using refrigerant piping between an indoor and outdoor unit instead of ducting air directly from the outdoor unit. Indoor units with directional vents mount onto walls, suspended from ceilings, or fit into the ceiling. Other indoor units mount inside the ceiling cavity, so that short lengths of duct handle air from the indoor unit to vents or diffusers around the rooms.
In the United States, HVAC engineers generally are members of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), EPA Universal CFC certified (for installation and service of CFC HVAC devices), or locally engineer certified such as a Special to Chief Boilers License issued by the state or, in some jurisdictions, the city. ASHRAE is an international technical society for all individuals and organizations interested in HVAC. The Society, organized into regions, chapters, and student branches, allows exchange of HVAC knowledge and experiences for the benefit of the field's practitioners and the public. ASHRAE provides many opportunities to participate in the development of new knowledge via, for example, research and its many technical committees. These committees typically meet twice per year at the ASHRAE Annual and Winter Meetings. A popular product show, the AHR Expo, is held in conjunction with each winter meeting. The Society has approximately 50,000 members and has headquarters in Atlanta, Georgia.
Replacing a capacitor is easy. Just take a photo of the wires before disconnecting anything (you may need a reference later on). Then discharge the stored energy in the old capacitor (Photo 4). Use needle-nose pliers to pluck one wire at a time from the old capacitor and snap it onto the corresponding tab of the new capacitor. The female crimp connectors should snap tightly onto the capacitor tabs. Wiggle each connector to see if it’s tight. If it’s not, remove the connector and bend the rounded edges of it so it makes a tighter fit on the tab. When you’ve swapped all the wires, secure the new capacitor (Photo 5).
We are so happy with the service and the unit installed. Carlos, the sales representative, was very attentive to our needs at the time. He knew exactly what we needed for our a/c concerns. Brandon Hayword, the a/c installer was amazing. I have never seen a technician so meticulous. Every detail was attended to. Poor guy worked from morning till 4:00 Am the next day. Never heard a complaint or wanted to go home and call it a night. Again, thank-you for the great service.
Inspect your furnace thermostat by first making sure that it’s turned on. Also, ensure that the thermostat switch is turned to “heat” and not “cool”. If your furnace will still not start with the thermostat on, try adjusting the temperature settings to a few degrees higher. Inspect any visible wires for breaks or splits, and make sure your thermostat batteries are not dead. Do not touch any open wires; contact a professional.
We are open from 7am to 10pm every weekday and from 7am to 8pm on weekends. We book appointments in a 2 hour arrival window and call 30-45 mins before we arrive so you do not have to sit around waiting. It is often possible to schedule your appointment in the evening or morning hours to avoid conflicting with your work schedule. Are you looking for service today? Give us a call or click on one of the Schedule Service buttons found on the top and left sides of this page to contact us today.
Natural ventilation is the ventilation of a building with outside air without using fans or other mechanical systems. It can be via operable windows, louvers, or trickle vents when spaces are small and the architecture permits. In more complex schemes, warm air is allowed to rise and flow out high building openings to the outside (stack effect), causing cool outside air to be drawn into low building openings. Natural ventilation schemes can use very little energy, but care must be taken to ensure comfort. In warm or humid climates, maintaining thermal comfort solely via natural ventilation might not be possible. Air conditioning systems are used, either as backups or supplements. Air-side economizers also use outside air to condition spaces, but do so using fans, ducts, dampers, and control systems to introduce and distribute cool outdoor air when appropriate.
SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
The summers here in Alexandria can range from almost pleasant to downright brutal. And you know as well as we do that it’s those latter days when your central AC or heat pump will decide to go down! But you don’t have to seek solace at the Waterfront or over at Cameron Run Regional Park. The secret to restoring your comfort lies with the certified specialists at HVAC & Plumbing Unlimited!
If a heat exchanger cracks or contains holes, leaks can release carbon monoxide into your home. Carbon monoxide is nearly impossible for humans to detect on their own due to its characteristics of being colorless and odorless. Because of this, it is referred to as “The Silent Killer”. Some symptoms of carbon monoxide poisoning include headache, dizziness, fatigue, nausea and vomiting. It is extremely important to have a HVAC technician perform a furnace inspection annually to prevent problems such as carbon monoxide poisoning. UGI Heating, Cooling & Plumbing offers yearly maintenance packages and service agreements that include yearly maintenance and furnace inspections.

A pinging or popping sound coming from the duct work can come from thermal expansion—the ductwork expanding and contracting as it heats and cools.  Or, air blowing past a loose flap of metal can make the sound. Track along the duct runs, listening for the sound. If you locate it, make a small dent in the sheet metal to provide a more rigid surface that’s less likely to move as it heats and cools.
American design standards are legislated in the Uniform Mechanical Code or International Mechanical Code. In certain states, counties, or cities, either of these codes may be adopted and amended via various legislative processes. These codes are updated and published by the International Association of Plumbing and Mechanical Officials (IAPMO) or the International Code Council (ICC) respectively, on a 3-year code development cycle. Typically, local building permit departments are charged with enforcement of these standards on private and certain public properties.
×