Although your AC may continue to work for a time, if you ignore warning signs of air conditioner repair troubles, it can be much more costly to repair in the long term. Diminished cooling capacity not only makes your home uncomfortably warm, but it also raises your utility bills significantly as your unit struggles to maintain the desired temperature ineffectively. A system put under strain is likely to overheat, resulting in major damage. Therefore, it is best to have your air conditioner repaired promptly when you discover signs of trouble. 
As a Carrier Factory Authorized Dealer, we are qualified in the most widely recognized and innovative selection of heating, cooling, and air quality options to satisfy any demand. From new installation and retrofit projects, to seasonal maintenance and repair, Modern Air Solutions optimizes the performance of equipment, targeting energy efficiency, reliability, and longevity.
Consequently, this water must exit the air handler—typically through plastic pipe or a drain tube. That drain tube goes directly outside, often terminating near the compressor, or to a floor drain or to a small electric “condensate pump” located by the air handler. Where a condensate pump is used, it connects to a 1/2-inch vinyl or rubber tube that exits outdoors or to a drain.
In 1995, Germany made CFC refrigerators illegal.[22] DuPont and other companies blocked the refrigerant in the U.S. with the U.S. EPA, disparaging the approach as "that German technology".[21][23] Nevertheless, in 2004, Greenpeace worked with multinational corporations like Coca-Cola and Unilever, and later Pepsico and others, to create a corporate coalition called Refrigerants Naturally!.[22][24] Then, four years later, Ben & Jerry's of Unilever and General Electric began to take steps to support production and use in the U.S.[25] In 2011 the EPA decided in favor of the ozone- and climate-safe refrigerant for U.S. manufacture.[17][26][27]
Close all the windows in the house, turn off all the fans and exhaust fans, and shut off the furnace. Light some incense and walk slowly around the outer walls of the house. Anywhere you notice the smoke blowing away from something or being sucked toward something, there’s probably an air leak. Now that you’ve found it, seal it! Here’s how. Here are more ways to improve energy efficiency in your home.
Visit our one-of-a-kind showroom and explore the latest options on the market today. Check out sound decibel levels, heating and cooling capacity, learn how these systems work and compare old to new. The team from Strongsville Heating & Air Conditioning provides the products, guidance and service you can trust to surpass all your expectations. The weather is no match for our dedication to your satisfaction. At Strongsville Heating & Air Conditioning Customers Set the Goal….We Exceed It! 

SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
HVAC is an important part of residential structures such as single family homes, apartment buildings, hotels and senior living facilities, medium to large industrial and office buildings such as skyscrapers and hospitals, vehicles such as cars, trains, airplanes, ships and submarines, and in marine environments, where safe and healthy building conditions are regulated with respect to temperature and humidity, using fresh air from outdoors.
Should you need to replace an air conditioning unit, Abacus Plumbing recommends Lennox brand of air conditioning and heating systems. Lennox systems offer the highest level of home comfort at the lowest possible cost of operation. Additionally, these systems are praised by consumer publications and meet or exceed all government standards for efficiency. Learn more about installation »

Many disconnect blocks contain two cartridge fuses. Check them before you proceed with repairs (Photo 3). A blown fuse is a sign of a failing part inside the condensing unit. So don’t just replace it and think you’ve solved the problem. Instead, replace the parts we show here. Then install new fuses and fire up the unit. If it blows again, call a pro—you’ve got more serious issues.


Free cooling systems can have very high efficiencies, and are sometimes combined with seasonal thermal energy storage so that the cold of winter can be used for summer air conditioning. Common storage mediums are deep aquifers or a natural underground rock mass accessed via a cluster of small-diameter, heat-exchanger-equipped boreholes. Some systems with small storages are hybrids, using free cooling early in the cooling season, and later employing a heat pump to chill the circulation coming from the storage. The heat pump is added-in because the storage acts as a heat sink when the system is in cooling (as opposed to charging) mode, causing the temperature to gradually increase during the cooling season.
Poorly maintained water cooling towers can promote the growth and spread of microorganisms,[56] such as Legionella pneumophila, the infectious agent responsible for Legionnaires' disease, or thermophilic actinomycetes. As long as the cooling tower is kept clean (usually by means of a chlorine treatment), these health hazards can be avoided or reduced. Excessive air conditioning can have a negative effect on skin, causing it to dry out, and can also cause dehydration.[citation needed]
The heat-exchanger cools the air that is being forced through it by the furnace blower. As the warm air comes in contact with this cool surface the water in the air condenses. By pulling the water molecules from the air. According to the psychometric chart[42] as relative humidity decreases in order to feel cool you will have to lower the temperature even more. A common way to counteract this effect is by installing a whole-home humidifier.[43] Similarly, installing a high efficient system this need to turn the temperature down wont have such and influence on your energy costs.
Air conditioning and refrigeration are provided through the removal of heat. Heat can be removed through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are referred to as refrigerants. A refrigerant is employed either in a heat pump system in which a compressor is used to drive thermodynamic refrigeration cycle, or in a free cooling system which uses pumps to circulate a cool refrigerant (typically water or a glycol mix).
Absorption refrigerator Air barrier Air conditioning Antifreeze Automobile air conditioning Autonomous building Building insulation materials Central heating Central solar heating Chilled beam Chilled water Constant air volume (CAV) Coolant Dedicated outdoor air system (DOAS) Deep water source cooling Demand-controlled ventilation (DCV) Displacement ventilation District cooling District heating Electric heating Energy recovery ventilation (ERV) Firestop Forced-air Forced-air gas Free cooling Heat recovery ventilation (HRV) Hybrid heat Hydronics HVAC Ice storage air conditioning Kitchen ventilation Mixed-mode ventilation Microgeneration Natural ventilation Passive cooling Passive house Radiant heating and cooling system Radiant cooling Radiant heating Radon mitigation Refrigeration Renewable heat Room air distribution Solar air heat Solar combisystem Solar cooling Solar heating Thermal insulation Underfloor air distribution Underfloor heating Vapor barrier Vapor-compression refrigeration (VCRS) Variable air volume (VAV) Variable refrigerant flow (VRF) Ventilation
A pinging or popping sound coming from the duct work can come from thermal expansion—the ductwork expanding and contracting as it heats and cools.  Or, air blowing past a loose flap of metal can make the sound. Track along the duct runs, listening for the sound. If you locate it, make a small dent in the sheet metal to provide a more rigid surface that’s less likely to move as it heats and cools.
In the United States, HVAC engineers generally are members of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), EPA Universal CFC certified (for installation and service of CFC HVAC devices), or locally engineer certified such as a Special to Chief Boilers License issued by the state or, in some jurisdictions, the city. ASHRAE is an international technical society for all individuals and organizations interested in HVAC. The Society, organized into regions, chapters, and student branches, allows exchange of HVAC knowledge and experiences for the benefit of the field's practitioners and the public. ASHRAE provides many opportunities to participate in the development of new knowledge via, for example, research and its many technical committees. These committees typically meet twice per year at the ASHRAE Annual and Winter Meetings. A popular product show, the AHR Expo, is held in conjunction with each winter meeting. The Society has approximately 50,000 members and has headquarters in Atlanta, Georgia.

Variable-speed technology allows more energy saving potential and improved comfort levels throughout the home.  The ability of the system to automatically adjust speeds according to the needs of the home ensures the right amount of comfort control, right when you need it.  Outside temperatures rarely, if ever, require your HVAC system to operate at 100% capacity.  Variable-speed units determine optimal cooling needs and vary speeds in increments between 40% and 100%.  Not only does this tailor comfort, but by running at lower speeds and consuming less power, you’ll save a significant amount off monthly utility expenses.
The fan limit switch controls the furnace blower. The fan limit switch has three settings: “Fan On”, “Fan Off”, and “Limit”. In the “Fan Off” setting, the blower will only operate if there is warm air in the plenum to prevent cool air from blowing into the home. The “Fan On” setting will keep the blower operating even after the burner has shutdown, making sure that all of the hot air produced is circulated. The “Limit” setting is a safety control that will turn the burner off in the rare event that the air in the warm air plenum reaches an unsafe temperature. This may be the case if ducts are blocked or if the system controls are malfunctioning.
Vredevoogd Heating & Cooling is Michigan’s top Heating & Air – Furnace Repair & Replacement – Air Conditioning Repair and installation service. With decades of experience and expertise, Vredevoogd Heating & Cooling remains committed to offering affordable 24/7 service. Our skilled heating and cooling specialists are certified and background checked. Our team is here when you need us to meet all your heating and cooling needs.

Vredevoogd Heating & Cooling technicians routinely assist our customers to figure out when it’s time to upgrade their Heating or Cooling system. Naturally, repairs are part of routine maintenance over the years. However, new models can save homeowners in a big way on energy expenses with their energy-efficient makeup. When you are ready to get a new system, we will do a careful check of your energy needs so that you can select the ideal system for your home’s needs. The wrong HVAC system for your home is a 15 year mistake that no one should have to afford. We install the right system for your home. Moreover, we offer guarantees that you won’t find just anywhere else. If your new installation isn’t right for your home, we’ll remove it free of charge at any time within that first year and refund 100% of your money. Our customers are burdened with no risks. We take on the risk because we are that sure of our expertise. We back our work with the strongest warranties in the field. In fact, we offer a wide array of warranties to provide you with the peace of mind you deserve as a valued Vredevoogd Heating & Cooling Grand Rapids MI customer.

To earn distinction as a Carrier Factory Authorized Dealer, Kabran Air Conditioning & Heating performs to exacting standards of customer dedication, business practices, and technical know-how.  Our technicians continue intensive factory training to remain current with increasingly sophisticated products and technology.  Our sales team attends Carrier University, ensuring complete product understanding and knowledgeable recommendations that perfectly suit your needs.  We maintain proper licensing, insurance and liability coverage, and fulfill warranty obligations in a timely manner.  By becoming experts in the state-of-the-art heating and cooling systems we install, accurate sizing, precision implementation, and long-term value is standard operating procedure at Kabran Air Conditioning & Heating.
In 1758, Benjamin Franklin and John Hadley, a chemistry professor at Cambridge University, conducted an experiment to explore the principle of evaporation as a means to rapidly cool an object. Franklin and Hadley confirmed that evaporation of highly volatile liquids (such as alcohol and ether) could be used to drive down the temperature of an object past the freezing point of water. They conducted their experiment with the bulb of a mercury thermometer as their object and with a bellows used to speed up the evaporation. They lowered the temperature of the thermometer bulb down to −14 °C (7 °F) while the ambient temperature was 18 °C (64 °F). Franklin noted that, soon after they passed the freezing point of water 0 °C (32 °F), a thin film of ice formed on the surface of the thermometer's bulb and that the ice mass was about 6 mm (1⁄4 in) thick when they stopped the experiment upon reaching −14 °C (7 °F). Franklin concluded: "From this experiment one may see the possibility of freezing a man to death on a warm summer's day."[9]
×