The Environmental Protection Agency (EPA) requires that all technicians who open a system containing a controlled refrigerant be certified to do so. There are four levels of certification, one of which is a “universal” certification to allow the HVAC technician to work on any type of equipment containing refrigerant. Your HVAC technician should be certified as “Level II Certified” at a minimum or, preferably, “Universal Certification” to work on your central air conditioner. Obtaining this certification information from your professional HVAC technician may be required in the event you are working with a realtor to sell your home. Costs for certification average $40 to $240.
As a technical industry, the heating and cooling field is associated with annual advances. New energies make our industry an exciting place to work. Our team thrives on keeping up to date with all changes in the HVAC field. We are here to share our knowledge with each customer. When you are ready to update your HVAC system, we can help you select the ideal system for your home.
The performance of vapor compression refrigeration cycles[27] is limited by thermodynamics. These air conditioning and heat pump devices move heat rather than convert it from one form to another, so thermal efficiencies do not appropriately describe the performance of these devices. The Coefficient-of-Performance (COP) measures performance, but this dimensionless measure has not been adopted. Instead, the Energy Efficiency Ratio (EER) has traditionally been used to characterize the performance of many HVAC systems. EER is the Energy Efficiency Ratio based on a 35 °C (95 °F) outdoor temperature. To more accurately describe the performance of air conditioning equipment over a typical cooling season a modified version of the EER, the Seasonal Energy Efficiency Ratio (SEER), or in Europe the ESEER, is used. SEER ratings are based on seasonal temperature averages instead of a constant 35 °C (95 °F) outdoor temperature. The current industry minimum SEER rating is 14 SEER.[28]

We had an exceptional experience with Gator Air, in particular Carlos. He presented us with quotes for different types of AC units, told us facts about said units and left us to make our decision. No high pressure sales. The installers were professional and cleaned up when they were through. A nice surprise was the 1 year free maintenance of the unit. We belonged to the Gator Club so to not have to pay it for the next year was an added bonus. Thank you GatorAir for making the experience an enjoyable one.

Before opening the electrical cover on the A/C unit, be sure to shut off all power to the compressor unit and the indoor furnace or air handler, and verify that it is off. Note that this may mean shutting off a circuit breaker that serves the furnace and air handler, and then, near the compressor, pulling out the disconnect block (or shutting off the 220-volt power) to the outdoor compressor.
Our furnace quit lighting yesterday. I called Cool Tech around 7pm and they offered to come out after hours, but I chose to set up an appointment today. The technician John called me at 7:30am and was there about 8am as promised. He was very courteous and replaced the igniter quickly. The heater is back to working properly. This is my second time hiring Cool Tech and they will continue to be my go-to heating and air conditioning guys.

The compressor-based refrigerant systems are air-cooled, meaning they use air to exchange heat, in the same way as a car radiator or typical household air conditioner does. Such a system dehumidifies the air as it cools it. It collects water condensed from the cooled air and produces hot air which must be vented outside the cooled area; doing so transfers heat from the air in the cooled area to the outside air.

As a Carrier Factory Authorized Dealer, we are qualified in the most widely recognized and innovative selection of heating, cooling, and air quality options to satisfy any demand. From new installation and retrofit projects, to seasonal maintenance and repair, Modern Air Solutions optimizes the performance of equipment, targeting energy efficiency, reliability, and longevity.


Furnaces and thermostats are not mix-and-match appliances. Using the wrong type of thermostat with a furnace will cause operating problems and can be dangerous. Although thermostats look similar, they are designed very differently. There are numerous types of heating systems and thermostat systems and they need to be coordinated for safe and proper operation. There are three types of thermostat systems used today: millivoltage, low voltage, and line voltage.​
If you have a heating or cooling emergency, call Vredevoogd Heating & Cooling Grand Rapids MI, Furnace Repair Lansing, Furnace Repair Kalamazoo and more at 616-828-5411. When you call you speak directly with one of our service representatives about the problem you are experiencing and schedule a service appointment. Naturally, we prioritize emergencies so you can count on us when your heating or cooling systems fail. After regular business hours, you can reach our customer service staff who will report your problem to on-call technicians. You can expect to hear back from a certified tech within 15 minutes of your call. Your heating and cooling emergency is important to us. We will visit your home ASAP to provide you with the superior service you’d expect from a Furnace Repair, Air Conditioning, AC Repair & HVAC leader like Vredevoogd Heating & Cooling Grand Rapids, AC Repair Lansing, AC Repair Kalamazoo.
Furnace breakdowns, no cooling when outside temperatures are soaring – heating and cooling repairs often catch us unexpectedly, making HVAC repair costs quite a surprise. Many homeowners worry when calling the HVAC repair contractor because of unexpected costs – your heating and cooling contractor won’t be able to give you a price for the repairs needed until he or she inspects the system to find the source of the problem.
Visit our one-of-a-kind showroom and explore the latest options on the market today. Check out sound decibel levels, heating and cooling capacity, learn how these systems work and compare old to new. The team from Strongsville Heating & Air Conditioning provides the products, guidance and service you can trust to surpass all your expectations. The weather is no match for our dedication to your satisfaction. At Strongsville Heating & Air Conditioning Customers Set the Goal….We Exceed It!
If you hear clicking that is followed by a hum or buzz, you’re probably hearing the fan motor attempting to start without the boost it needs from the capacitor. You can almost always conclude that the capacitor has failed. Sometimes you can get the compressor fan spinning (clockwise) by pushing it with a thin stick or long screwdriver poked through the grille. But the chances are good that this might work for one cycle, but the capacitor will fail next time the AC goes on. It’s best to replace the capacitor.
Your HVAC professional can also help you verify that your system is properly matched by providing you with an AHRI Certificate of Certified Product Performance upon request. The certificate verifies that the outdoor unit (condenser) and the indoor unit (evaporator) combination has been certified as a matched system by the Air Conditioning, Heating and Refrigeration Institute (AHRI). For higher efficiency systems, this certification may help you obtain a rebate from your utility or local municipality if you have to replace your unit in whole or in part. Not all areas offer a rebate, but your technician will likely be able to provide information about the certification process. Fees for performing this certification vary, but generally are relatively inexpensive.
1) Your air conditioner is not working at all. Before calling in a professional to address this issue, you may want to check a few things yourself. Check to see if your thermostat is set to “cool”. Confirm that your designated cooling temperature is less than the temperature of the room or home. If everything is set correctly, check the electrical panel to be sure you do not have a tripped breaker. If these things all check out and your air condition unit is still not working, it is time to call in a professional.
If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.
To earn distinction as a Carrier Factory Authorized Dealer, Kabran Air Conditioning & Heating performs to exacting standards of customer dedication, business practices, and technical know-how.  Our technicians continue intensive factory training to remain current with increasingly sophisticated products and technology.  Our sales team attends Carrier University, ensuring complete product understanding and knowledgeable recommendations that perfectly suit your needs.  We maintain proper licensing, insurance and liability coverage, and fulfill warranty obligations in a timely manner.  By becoming experts in the state-of-the-art heating and cooling systems we install, accurate sizing, precision implementation, and long-term value is standard operating procedure at Kabran Air Conditioning & Heating.
Our company is in the business of providing reliable and affordable residential and building maintenance services to help property owners preserve the aesthetic and functionality of their spaces. Our goal is to make sure that our clients will get the best service that will meet and exceed their satisfaction. The moment you book our services, you can guarantee that whatever maintenance issues you might have will be handled with utmost professionalism and credibility.
Energy efficiency can be improved even more in central heating systems by introducing zoned heating. This allows a more granular application of heat, similar to non-central heating systems. Zones are controlled by multiple thermostats. In water heating systems the thermostats control zone valves, and in forced air systems they control zone dampers inside the vents which selectively block the flow of air. In this case, the control system is very critical to maintaining a proper temperature.
The burner can be fueled by gas or by oil. It is the component that creates the required heat. It can be controlled by a thermostat or by the fan limit control, which is located in the plenum chamber. A dirty air filter or a blocked fan can cause the burner to turn off and on more frequently than necessary. If you are experiencing this issue, the first thing you should try is to change the air filter. If that does not help the issue, contact UGI Heating, Cooling & Plumbing and we will send an expert technician to further troubleshoot your gas or oil furnace burner issues.

Refrigeration air conditioning equipment usually reduces the absolute humidity of the air processed by the system. The relatively cold (below the dewpoint) evaporator coil condenses water vapor from the processed air, much like an ice-cold drink will condense water on the outside of a glass. Therefore, water vapor is removed from the cooled air and the relative humidity in the room is lowered. The water is usually sent to a drain or may simply drip onto the ground outdoors. The heat is ejected by the air conditioners condenser, which is located outside of the area being cooled.
Architectural acoustics Architectural engineering Architectural technologist Building services engineering Building information modeling (BIM) Deep energy retrofit Duct leakage testing Environmental engineering Hydronic balancing Kitchen exhaust cleaning Mechanical engineering Mechanical, electrical, and plumbing Mold growth, assessment, and remediation Refrigerant reclamation Testing, adjusting, balancing
The thermocouple is a copper rod that the pilot flame heats-up. When it gets hot enough, the thermocouple signals that there is enough heat to burn the gas fuel being released into the appliance—and so it allows the gas to be released to the burners. In some cases where the pilot light won’t stay lit, the thermocouple needs to be adjusted or replaced. This is generally a job for a professional.
Dichlorodifluoromethane (R-12) was the most common blend used in automobiles in the U.S. until 1994, when most designs changed to R-134A due to the ozone-depleting potential of R-12. R-11 and R-12 are no longer manufactured in the U.S. for this type of application, so the only source for air-conditioning repair purposes is the cleaned and purified gas recovered from other air conditioner systems. Several non-ozone-depleting refrigerants have been developed as alternatives, including R-410A. It was first commercially used by Carrier Corp. under the brand name Puron.[citation needed]
You might guess it from the name: the heat exchanger is the part of your furnace that actually heats the air your blower motor pushes through the furnace. It consists of a chamber in which the heat energy produced by natural or propane gas is transferred to the forced air. At the same time, this part also includes a vent through which the gases themselves are safely removed from the unit and the air that enters your home. Because of these gases, a problem with your heat exchanger needs to be dealt with promptly. Over time, cracks in the exchanger can result in carbon monoxide leaks. Taking care of the problem once again means understanding the existence of a range: repairing your heat exchanger can cost as little as $100, but a full replacement may cost up to $1,200.

Refrigeration air conditioning equipment usually reduces the absolute humidity of the air processed by the system. The relatively cold (below the dewpoint) evaporator coil condenses water vapor from the processed air, much like an ice-cold drink will condense water on the outside of a glass. Therefore, water vapor is removed from the cooled air and the relative humidity in the room is lowered. The water is usually sent to a drain or may simply drip onto the ground outdoors. The heat is ejected by the air conditioners condenser, which is located outside of the area being cooled. 
×