In 1992, a non-governmental organization, Greenpeace, was spurred by corporate executive policies and requested that a European lab find substitute refrigerants. This led to two alternatives, one a blend of propane (R290) and isobutane (R600a), and one of pure isobutane.[18][22] Industry resisted change in Europe until 1993, and in the U.S. until 2011, despite some supportive steps in 2004 and 2008 (see Refrigerant Development above).[27][68]

Vredevoogd Heating & Cooling stands behind its services and products with the strongest guarantees you’ll find anywhere. When you invite us into your home to service or install your HVAC system or do Furnace Repair work in Grand Rapids and beyond, we perform our job with an outstanding level of care and efficiency. Having served Michigan for 54 years, we never rest on our laurels. To remain the best, we intend to give our best every time, every job.
You can usually slip the belt on the motor’s (smaller) pulley first and then start it on the blower pulley. Rotate the blower pulley by hand, holding the belt in place but keeping your fingers from getting caught between the belt and the pulley. The belt should slip right into place. If it seems to be too tight or difficult to set in place, it may be necessary to adjust the motor mount to provide more slack.
Within the construction sector, it is the job of the building services engineer to design and oversee the installation and maintenance of the essential services such as gas, electricity, water, heating and lighting, as well as many others. These all help to make buildings comfortable and healthy places to live and work in. Building Services is part of a sector that has over 51,000 businesses and employs represents 2%-3% of the GDP.

Circulating refrigerant vapor enters the compressor, where its pressure and temperature are increased. The hot, compressed refrigerant vapor is now at a temperature and pressure at which it can be condensed and is routed through a condenser. Here it is cooled by air flowing across the condenser coils and condensed into a liquid. Thus, the circulating refrigerant removes heat from the system and the heat is carried away by the air. The removal of this heat can be greatly augmented by pouring water over the condenser coils, making it much cooler when it hits the expansion valve.
High-efficiency condensing furnaces (90% AFUE and above) are a bit more complex than conventional furnaces. The main differences between a conventional and condensing furnace are the heat exchanger technology used to extract heat from the combustion process and the method used to exhaust the combustion gases. In these ways, the furnaces are very different. The condensing furnace does not have a significantly more efficient combustion process than does a conventional furnace; both use gas burners with electronic ignition. The difference lies in that the condensing furnace has a more efficient heat extraction process after combustion.
Demand controlled kitchen ventilation (DCKV) is a building controls approach of slowing down kitchen exhaust fans and subsequent supply air in response to the actual cooking loads in a commercial kitchen. Traditional commercial kitchen ventilation systems operate at 100% fan speed independent of the volume of cooking activity and DCKV technology changes that to provide significant fan energy and conditioned air savings. By deploying smart sensing technology, both the exhaust and supply fans can be controlled to capitalize on the Law of Affinity for motor energy savings, reduce makeup air heating and cooling energy, increasing safety and reducing ambient kitchen noise levels.[30]
Our tenant called at 8:00 pm on a Friday night to say the air conditioner was not working. We placed a call to Gator and immediately received a call from the tech asking for tenant's name and contact information. He called back after visiting the sight to say he got the system working again but recommended we install a new unit. My husband met with Carlos a few days later and scheduled installation for the following week. Carlos met with my husband again after the installation to go over the details of the new unit and to ensure he was satisfied with the job. The installers Brandon Hayword and Christian Winslow not only did a top-notch job, but they left the work site exactly how they found it. From start to finish, my husband and I were impressed by the level of professionalism exhibited by all of Gator's employees. We decided Gator is our new HVAC company.

Has another company told you that your furnace has a cracked heat exchanger?  The heat exchanger is the heart of your furnace. Its failure can result in a dangerous situation for your home and the best solution is usually a new furnace.  Because of these issues, Bonney takes this situation very seriously.  We will offer you proof of the cracked heat exchanger in the form of a picture from our video inspection camera or a report from our exhaust gas analyzer, before we make our recommendation.


The burner can be fueled by gas or by oil. It is the component that creates the required heat. It can be controlled by a thermostat or by the fan limit control, which is located in the plenum chamber. A dirty air filter or a blocked fan can cause the burner to turn off and on more frequently than necessary. If you are experiencing this issue, the first thing you should try is to change the air filter. If that does not help the issue, contact UGI Heating, Cooling & Plumbing and we will send an expert technician to further troubleshoot your gas or oil furnace burner issues.
Your HVAC professional can perform a yearly tune-up of your system for around $80-$100. This yearly maintenance can go far toward heading off major repairs to your system and provide you with peace of mind and considerable savings in the long term. Additionally, regular servicing of your AC unit can help a home inspector to certify that your unit is working properly in the event you decide to sell your home.
Air Conditioning Your home's air conditioner is an essential part of your overall indoor comfort. A properly working system can mean the difference between a cool, comfortable summer and a hot, miserable few months. If you're currently dealing with a broken air conditioner, an inefficient system, or you would like to schedule a routine, pre-season tune-up, Horizon Services is here to help!
Most modern air-conditioning systems feature a dehumidification cycle during which the compressor runs while the fan is slowed as much as possible[citation needed] to reduce the evaporator temperature and therefore condense more water. When the temperature falls below a threshold, both the fan and compressor are shut off to mitigate further temperature drops;[clarification needed] this prevents moisture on the evaporator from being blown back into the room.[citation needed] When the temperature rises again,[clarification needed] the compressor restarts and the fan returns to low speed.

The main problem when installing a multi-split system is the laying of long refrigerant lines for connecting the external unit to the internal ones. While installing a separate split system, workers try to locate both units opposite to each other, where the length of the line is minimal. Installing a multi-split system creates more difficulties, since some of indoor units can be located far from the outside. The first models of multi-split systems had one common control system that did not allow you to set the air conditioning individually for each room. However, now the market has a wide selection of multi-split systems, in which the functional characteristics of indoor units operate separately from each other.


1) Change your filter. The simplest and most effective way to keep your AC running smoothly is changing your filter once a month. By regularly changing your filter, you reduce a lot of the burden on your system. A dirty or clogged filter makes your air conditioner work much harder than does a clean filter. Changing your filters regularly is easy on your budget and easy on your system as well. It will lower your utility bill and extend the life of your AC.
×