A heat pump is an air conditioner in which the refrigeration cycle can be reversed, producing heating instead of cooling in the indoor environment. They are also commonly referred to as a "reverse cycle air conditioner". The heat pump is significantly more energy efficient than electric resistance heating. Some homeowners elect to have a heat pump system installed as a feature of a central air conditioner. When the heat pump is in heating mode, the indoor evaporator coil switches roles and becomes the condenser coil, producing heat. The outdoor condenser unit also switches roles to serve as the evaporator, and discharges cold air (colder than the ambient outdoor air).
Air conditioning and refrigeration are provided through the removal of heat. Heat can be removed through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are referred to as refrigerants. A refrigerant is employed either in a heat pump system in which a compressor is used to drive thermodynamic refrigeration cycle, or in a free cooling system which uses pumps to circulate a cool refrigerant (typically water or a glycol mix).
Gainesville Mechanical Inc is open for regular business hours, Monday through Friday, from 8 a.m. to 5 p.m. We offer everyday extended business hours, at regular rates, to meet the challenge of your busy schedule with flexible appointment times, and always have a licensed technician at your door within 24 hours.  For desperate times, we protect your home, comfort, and safety with 24/7 Emergency Assistance without added after-hour costs.  Contact us at 770-532-9130, and rest assured, we prioritize your best interests.  Our skilled service never comes with inflated or hidden charges.  We provide affordable rates, upfront pricing, and the detailed information you need to make the best possible decisions.  We service all makes and models of cooling equipment, optimizing safety, efficiency, and reliability, to deliver superior, ongoing performance.  Trust our award-winning team of NATE-certified technicians to restore your comfort today, with repairs that ensure long-term satisfaction.
The blower assembly is located between your main furnace and the cold air return. The blower is responsible for pulling air from your home and then sending it through the furnace and the heat exchanger. The air gets circulated throughout the home via the duct work. The furnace’s air filter is contained within the blower compartment. Regular-style filters should be replaced or cleaned each month.

Cleaning the debris that builds up on your filters will aid with the flow of air. When your air filter is clogged, your air handler must work harder to compensate for the blockage of air flow. In addition to driving up your utility bill, the reduced air flow through your heating and cooling system can cause your heat exchanger to overheat and shut off too quickly.    
Cut down on energy costs and prevent damage to your furnace by addressing a gas furnace that's overactive or short cycling. Besides the need for consistently comfortable temperatures, this issue could cause long-term safety issues to your home, making it very important to address. From a faulty thermostat to a dirty filter, there are several possible causes to investigate.

Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.

×