The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
Modern air conditioning systems are not designed to draw air into the room from the outside, they only recirculate the increasingly cool air on the inside. Because this inside air always has some amount of moisture suspended in it, the cooling portion of the process always causes ambient warm water vapor to condense on the cooling coils and to drip from them down onto a catch tray at the bottom of the unit from which it must then be routed outside, usually through a drain hole. As this moisture has no dissolved minerals in it, it will not cause mineral buildup on the coils. This will happen even if the ambient humidity level is low. If ice begins to form on the evaporative fins, it will reduce circulation efficiency and cause the development of more ice, etc. A clean and strong circulatory fan can help prevent this, as will raising the target cool temperature of the unit's thermostat to a point that the compressor is allowed to turn off occasionally. A failing thermistor may also cause this problem. Refrigerators without a defrost cycle may have this same issue. Dust can also cause the fins to begin blocking air flow with the same undesirable result: ice.

Absorption heat pumps are a kind of air-source heat pump, but they do not depend on electricity to power them. Instead, gas, solar power, or heated water is used as a main power source. An absorption pump dissolves ammonia gas in water, which gives off heat. Next, the water and ammonia mixture is depressurized to induce boiling, and the ammonia is boiled off, which absorbs heat from the outdoor air.[citation needed]
A pinging or popping sound coming from the duct work can come from thermal expansion—the ductwork expanding and contracting as it heats and cools.  Or, air blowing past a loose flap of metal can make the sound. Track along the duct runs, listening for the sound. If you locate it, make a small dent in the sheet metal to provide a more rigid surface that’s less likely to move as it heats and cools.
This job involves removing the access panel, loosening a couple of bolts that hold the blower motor at the proper tension, and adjusting its distance or realigning the belt. In many cases, it’s a good idea to remove the belt and buy a replacement at a home center. Last, when reinstalling the belt, be careful not to over-tighten it; this can wear out the motor bearings.
Our company is in the business of providing reliable and affordable residential and building maintenance services to help property owners preserve the aesthetic and functionality of their spaces. Our goal is to make sure that our clients will get the best service that will meet and exceed their satisfaction. The moment you book our services, you can guarantee that whatever maintenance issues you might have will be handled with utmost professionalism and credibility.
Although HVAC is executed in individual buildings or other enclosed spaces (like NORAD's underground headquarters), the equipment involved is in some cases an extension of a larger district heating (DH) or district cooling (DC) network, or a combined DHC network. In such cases, the operating and maintenance aspects are simplified and metering becomes necessary to bill for the energy that is consumed, and in some cases energy that is returned to the larger system. For example, at a given time one building may be utilizing chilled water for air conditioning and the warm water it returns may be used in another building for heating, or for the overall heating-portion of the DHC network (likely with energy added to boost the temperature).[4][5][6]

This job involves removing the access panel, loosening a couple of bolts that hold the blower motor at the proper tension, and adjusting its distance or realigning the belt. In many cases, it’s a good idea to remove the belt and buy a replacement at a home center. Last, when reinstalling the belt, be careful not to over-tighten it; this can wear out the motor bearings.

Free cooling systems can have very high efficiencies, and are sometimes combined with seasonal thermal energy storage so that the cold of winter can be used for summer air conditioning. Common storage mediums are deep aquifers or a natural underground rock mass accessed via a cluster of small-diameter, heat-exchanger-equipped boreholes. Some systems with small storages are hybrids, using free cooling early in the cooling season, and later employing a heat pump to chill the circulation coming from the storage. The heat pump is added-in because the storage acts as a heat sink when the system is in cooling (as opposed to charging) mode, causing the temperature to gradually increase during the cooling season.
Air changes per hour Bake-out Building envelope Convection Dilution Domestic energy consumption Enthalpy Fluid dynamics Gas compressor Heat pump and refrigeration cycle Heat transfer Humidity Infiltration Latent heat Noise control Outgassing Particulates Psychrometrics Sensible heat Stack effect Thermal comfort Thermal destratification Thermal mass Thermodynamics Vapour pressure of water
A contactor is a $25 mechanical relay that uses low-voltage power from the thermostat to switch 220-volt high-amperage current to the compressor and condenser fan. AC contactors can wear out and are at the top of the list of common air conditioning service failures. Even if your contactor is working, it pays to replace it every five years or so. Unscrew the old contactor before removing the wires. Then move the wires to the new unit (photo 6).
A contactor is a $25 mechanical relay that uses low-voltage power from the thermostat to switch 220-volt high-amperage current to the compressor and condenser fan. AC contactors can wear out and are at the top of the list of common air conditioning service failures. Even if your contactor is working, it pays to replace it every five years or so. Unscrew the old contactor before removing the wires. Then move the wires to the new unit (photo 6).
In a thermodynamically closed system, any power dissipated into the system that is being maintained at a set temperature (which is a standard mode of operation for modern air conditioners) requires that the rate of energy removal by the air conditioner increase. This increase has the effect that, for each unit of energy input into the system (say to power a light bulb in the closed system), the air conditioner removes that energy.[30] To do so, the air conditioner must increase its power consumption by the inverse of its "efficiency" (coefficient of performance) times the amount of power dissipated into the system. As an example, assume that inside the closed system a 100 W heating element is activated, and the air conditioner has a coefficient of performance of 200%. The air conditioner's power consumption will increase by 50 W to compensate for this, thus making the 100 W heating element cost a total of 150 W of power.
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
Gainesville Mechanical Inc is open for regular business hours, Monday through Friday, from 8 a.m. to 5 p.m. We offer everyday extended business hours, at regular rates, to meet the challenge of your busy schedule with flexible appointment times, and always have a licensed technician at your door within 24 hours.  For desperate times, we protect your home, comfort, and safety with 24/7 Emergency Assistance without added after-hour costs.  Contact us at 770-532-9130, and rest assured, we prioritize your best interests.  Our skilled service never comes with inflated or hidden charges.  We provide affordable rates, upfront pricing, and the detailed information you need to make the best possible decisions.  We service all makes and models of cooling equipment, optimizing safety, efficiency, and reliability, to deliver superior, ongoing performance.  Trust our award-winning team of NATE-certified technicians to restore your comfort today, with repairs that ensure long-term satisfaction.
Trying to replace an HVAC unit when out of town isn't easy, but Gator Air made it seamless. I was able to quickly schedule the estimator to come to my property and I was emailed several options. I was never pushed to make a decision or "sold" unwanted options. The installers were punctual and professional. Outstanding follow up too. I highly recommend!
Your HVAC professional can perform a yearly tune-up of your system for around $80-$100. This yearly maintenance can go far toward heading off major repairs to your system and provide you with peace of mind and considerable savings in the long term. Additionally, regular servicing of your AC unit can help a home inspector to certify that your unit is working properly in the event you decide to sell your home.

Air-source heat pumps are more popular in milder winter climates where the temperature is frequently in the range of 4–13 °C (40–55 °F), because heat pumps become inefficient in more extreme cold. This is because ice forms on the outdoor unit's heat exchanger coil, which blocks air flow over the coil. To compensate for this, the heat pump system must temporarily switch back into the regular air conditioning mode to switch the outdoor evaporator coil back to being the condenser coil, so that it can heat up and defrost. A heat pump system will therefore have a form of electric resistance heating in the indoor air path that is activated only in this mode in order to compensate for the temporary indoor air cooling, which would otherwise be uncomfortable in the winter.
Recent Review: Metro Service was amazing. They came out on Saturday and secured the gas to a failing furnace to insure our safety. They came out on Monday and had the new furnace installed and operating within less than 4 hours. Polite, professional, meticulous and 35% lower than their competitors. I will be using them for all of my HVAC needs in the future.
The Environmental Protection Agency (EPA) requires that all technicians who open a system containing a controlled refrigerant be certified to do so. There are four levels of certification, one of which is a “universal” certification to allow the HVAC technician to work on any type of equipment containing refrigerant. Your HVAC technician should be certified as “Level II Certified” at a minimum or, preferably, “Universal Certification” to work on your central air conditioner. Obtaining this certification information from your professional HVAC technician may be required in the event you are working with a realtor to sell your home. Costs for certification average $40 to $240.
Heaters are appliances whose purpose is to generate heat (i.e. warmth) for the building. This can be done via central heating. Such a system contains a boiler, furnace, or heat pump to heat water, steam, or air in a central location such as a furnace room in a home, or a mechanical room in a large building. The heat can be transferred by convection, conduction, or radiation.

Most central air conditioners have two basic parts: an outdoor unit (compressor/condenser) that sits next to your home and an indoor unit (evaporator) that’s located in a central duct near your furnace. If you have a heat pump instead of a furnace, the indoor unit will be in the air handler. Use the same maintenance steps we show here. If your furnace looks different from the one shown or you have a heat pump, use the owner’s manual to find your way around it. The basic parts will be the same. Check out our step-by-step guide for deep-cleaning your home air conditioner.

Ductwork pinging or popping. If you hear a pinging or popping sound coming from metal ductwork, this may be caused by thermal expansion or by air blowing past a loose flap of metal. Track along the duct runs, listening for the sound. If you find it, make a small dent in the sheet metal to provide a more rigid surface that’s less likely to move as it heats and cools.


In the United States, HVAC engineers generally are members of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), EPA Universal CFC certified (for installation and service of CFC HVAC devices), or locally engineer certified such as a Special to Chief Boilers License issued by the state or, in some jurisdictions, the city. ASHRAE is an international technical society for all individuals and organizations interested in HVAC. The Society, organized into regions, chapters, and student branches, allows exchange of HVAC knowledge and experiences for the benefit of the field's practitioners and the public. ASHRAE provides many opportunities to participate in the development of new knowledge via, for example, research and its many technical committees. These committees typically meet twice per year at the ASHRAE Annual and Winter Meetings. A popular product show, the AHR Expo, is held in conjunction with each winter meeting. The Society has approximately 50,000 members and has headquarters in Atlanta, Georgia.
Recent Review: Metro Service was amazing. They came out on Saturday and secured the gas to a failing furnace to insure our safety. They came out on Monday and had the new furnace installed and operating within less than 4 hours. Polite, professional, meticulous and 35% lower than their competitors. I will be using them for all of my HVAC needs in the future.
Heaters are appliances whose purpose is to generate heat (i.e. warmth) for the building. This can be done via central heating. Such a system contains a boiler, furnace, or heat pump to heat water, steam, or air in a central location such as a furnace room in a home, or a mechanical room in a large building. The heat can be transferred by convection, conduction, or radiation.
Your HVAC professional can perform a yearly tune-up of your system for around $80-$100. This yearly maintenance can go far toward heading off major repairs to your system and provide you with peace of mind and considerable savings in the long term. Additionally, regular servicing of your AC unit can help a home inspector to certify that your unit is working properly in the event you decide to sell your home.

Recent Review: Metro Service was amazing. They came out on Saturday and secured the gas to a failing furnace to insure our safety. They came out on Monday and had the new furnace installed and operating within less than 4 hours. Polite, professional, meticulous and 35% lower than their competitors. I will be using them for all of my HVAC needs in the future.
A number of other variables can influence your decision on whether to repair or replace your furnace, as well. In addition to cost and brand, consider the expected lifetime of your furnace. If it is more than 15 years old, it might make more sense to invest in a new unit even if it costs more than simply repairing the current problem. Long-term costs also play into the equation. For example, your new furnace may be more energy efficient than the current unit. Even though you will pay more for the actual installation, you might be able to make back your investment through lower energy bills. To make your decision, consult with a reliable professional on what to do. In inspecting your furnace, they will be able to make an informed recommendation that looks not just to the next year, but years into the future. That way, you can make the best possible decision for your home and budget long-term.
In the refrigeration cycle, heat is transported from a colder location to a hotter area. As heat would naturally flow in the opposite direction, work is required to achieve this. A refrigerator is an example of such a system, as it transports the heat out of the interior and into its environment. The refrigerant is used as the medium which absorbs and removes heat from the space to be cooled and subsequently ejects that heat elsewhere.
Recent Review: Metro Service was amazing. They came out on Saturday and secured the gas to a failing furnace to insure our safety. They came out on Monday and had the new furnace installed and operating within less than 4 hours. Polite, professional, meticulous and 35% lower than their competitors. I will be using them for all of my HVAC needs in the future.
×