Clean air delivery rate is the amount of clean air an air cleaner provides to a room or space. When determining CADR, the amount of airflow in a space is taken into account. For example, an air cleaner with a flow rate of 100 cfm (cubic feet per minute) and an efficiency of 50% has a CADR of 50 cfm. Along with CADR, filtration performance is very important when it comes to the air in our indoor environment. Filter performance depends on the size of the particle or fiber, the filter packing density and depth and also the air flow rate.[31]
Any concern with your cooling system, however minor, is worth checking out.  NATE-certified technicians can quickly identify the problem and prevent more extensive and costly damage.  Catching defects quickly is the key to cost-effective repairs.  Elevated operational noise such as grinding, screeching, or wheezing is more than aggravating.  Think of those sounds as warning bells.  They’re an indication of component failure.  Listen to what they’re telling you and call for professional assistance.  Worn or misaligned belts are easily repaired.  Strange smells from contaminants such as mold or mildew are best handled before allergens enter breathing air, diminish airflow, and block the coil.  Temperature swings, unstable humidity, or extended run times are all signs of bigger problems on the way.  Call Ferran Services at 407-422-3551 (Orlando) or 386-322-6168 (Volusia), and our licensed technicians will perform a complete system check, ensuring safe, efficient and reliable operation.
If you believe that the ac not working or you’re getting little or no cold air, check these three things first. Make sure all the registers in the house are wide open. Then be sure the furnace filter is clean. Then go outside and clean off the condenser coils (Photo 2). If several registers were closed or the filter was clogged, the reduced airflow could have caused the evaporator coil to ice up and stop cooling your home. If you’ve changed the filter and opened all the registers and you’re still not getting airflow at the registers, deice the A-coil. Move the thermostat mode switch from “Cooling” to “Off” and move the fan switch from “Auto” to “On.” Let the blower run for at least 30 minutes or until there’s good airflow at the registers. Then turn the AC back on to test it. If it works for the next 12 hours, you’ve solved the problem.
At Horizon Services, we strive to provide all of our customers with the peace of mind that comes from knowing that you have a skilled team on-call for any AC emergencies that may arise. We have more than 300 fully stocked trucks ready to go at a moment's notice. Our Horizon technicians undergo rigorous training, including a mandatory 150 hours of training every year, to ensure that they're always up to date on the latest techniques and HVAC technology. Plus, we perform extensive background checks, including drug and criminal checks, on all of our employees so you don't have to worry about letting a stranger into your home when your AC breaks down in the middle of the night. When you're dealing with an air conditioning emergency, trust the experts at Horizon Services!
Replacing a capacitor is easy. Just take a photo of the wires before disconnecting anything (you may need a reference later on). Then discharge the stored energy in the old capacitor (Photo 4). Use needle-nose pliers to pluck one wire at a time from the old capacitor and snap it onto the corresponding tab of the new capacitor. The female crimp connectors should snap tightly onto the capacitor tabs. Wiggle each connector to see if it’s tight. If it’s not, remove the connector and bend the rounded edges of it so it makes a tighter fit on the tab. When you’ve swapped all the wires, secure the new capacitor (Photo 5). 
×