In 1992, a non-governmental organization, Greenpeace, was spurred by corporate executive policies and requested that a European lab find substitute refrigerants. This led to two alternatives, one a blend of propane (R290) and isobutane (R600a), and one of pure isobutane.[18][22] Industry resisted change in Europe until 1993, and in the U.S. until 2011, despite some supportive steps in 2004 and 2008 (see Refrigerant Development above).[27][68]
When your gas furnace isn’t blowing hot air, the issue could be due to a faulty pilot light or broken ignitor. Remove the furnace cover panel and visually inspect whether you can see a flame from the pilot light. A natural gas furnace will be blue and yellow in color, and a propane furnace should have a bluish green flame with a yellow tip. If you can see a flame and it appears normal, the issue could be related to the furnace blower motor or other complex furnace parts. If the flame appears low or non-existent, it’s best to contact an experienced furnace repair company. Remember to never touch any open wires; contact a professional.
An annual inspection of your unit can ensure that the various potential problems mentioned above are detected early, and before they require complete replacement. During this inspection, for instance, a professional might find small cracks in your heat exchanger or a faulty seal in your blower motor. Some manufacturer's warranties even require these annual inspections to maintain validity. Typically, your furnace inspection will cost between $80 and $150 depending on the area in which you live and the professional you work with.
A heat pump is an air conditioner in which the refrigeration cycle can be reversed, producing heating instead of cooling in the indoor environment. They are also commonly referred to as a "reverse cycle air conditioner". The heat pump is significantly more energy efficient than electric resistance heating. Some homeowners elect to have a heat pump system installed as a feature of a central air conditioner. When the heat pump is in heating mode, the indoor evaporator coil switches roles and becomes the condenser coil, producing heat. The outdoor condenser unit also switches roles to serve as the evaporator, and discharges cold air (colder than the ambient outdoor air).
In variable climates, the system may include a reversing valve that switches from heating in winter to cooling in summer. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa. This allows a facility to be heated and cooled by a single piece of equipment by the same means, and with the same hardware.
"Very impressed. Returned call within 24 hours. They came out the same day I spoke with them and made the repair within 25 minutes. Very low service call fee. I had another repair service out two weeks earlier and after 3 service calls and the central air still not fixed and temperatures in the high 90's, it was such a relief to have a company identify the problem, have the necessary part with them and fix the problem."

5) Adjust your thermostat. If you are away for long periods every day, adjust your thermostat to a higher temperature for the time you are away. This will lessen the amount of time your unit has to work each day and will lengthen its life cycle. An additional benefit will be a lower utility bill each month. Some newer thermostats allow you to pre-program your thermostat to match your schedule so that your home will still be cool when you arrive. Optimizing your system’s usage will maximize its life in the long term.


Air conditioning makes deep plan buildings feasible, for otherwise they would have to be built narrower or with light wells so that inner spaces received sufficient outdoor air via natural ventilation. Air conditioning also allows buildings to be taller, since wind speed increases significantly with altitude making natural ventilation impractical for very tall buildings.[citation needed] Comfort applications are quite different for various building types and may be categorized as:
The last thing you need is for your air conditioning to stop working in the middle of a heat wave. If this has ever happened to you, you understand the need for a reliable company to come out and get the air conditioning going again. Let us prove to you that we are the right company for you in Southern Maryland. As a service we do offer maintenance of all air conditioning units to help prevent this problem, but we understand that things happen!

Air conditioners can create a lot of water because they remove moisture from the air. To get rid of this, they have a [usually plastic] drain pipe that comes out of the side of the air handler. Over time, algae can block this pipe and, when it does, the AC won’t work. In fact, some condensate drains have a float switch that won’t let the AC run if water backs-up. Water can also puddle around the unit or flood the area. To deal with condensate problems, please see Air Conditioner Leaks Water, below.
Mr. Plumber provides fast, expert plumbing service to Smyrna, GA and is here for you with 24 hour emergency plumbing service. Our licensed and certified plumbers can tackle all your plumbing jobs including sink & faucet repair, toilet repair & replacement, water line repair & replacement, drain cleaning, bathtubs & shower installation and repair, water heater installation, sewer repair, backflow prevention and more. Our professional plumbers will respect your time, home and business. You approve the price before we perform our plumbing work and your satisfaction is guaranteed! Give us a call today for:

In the most general sense, air conditioning can refer to any form of technology that modifies the condition of air (heating, (de-) humidification, cooling, cleaning, ventilation, or air movement). In common usage, though, "air conditioning" refers to systems which cool air. In construction, a complete system of heating, ventilation, and air conditioning is referred to as HVAC.[3]
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
Energy efficiency can be improved even more in central heating systems by introducing zoned heating. This allows a more granular application of heat, similar to non-central heating systems. Zones are controlled by multiple thermostats. In water heating systems the thermostats control zone valves, and in forced air systems they control zone dampers inside the vents which selectively block the flow of air. In this case, the control system is very critical to maintaining a proper temperature.
Central, "all-air" air-conditioning systems (or package systems) with a combined outdoor condenser/evaporator unit are often installed in North American residences, offices, and public buildings, but are difficult to retrofit (install in a building that was not designed to receive it) because of the bulky air ducts required. (Minisplit ductless systems are used in these situations.) Outside of North America, packaged systems are only used in limited applications involving large indoor space such as stadiums, theatres or exhibition halls.
Our complaint-free A+ rating from the Better Business Bureau and Angie’s List Super Service Award evidences a longstanding tradition of customer satisfaction.  When you contact Kabran Air Conditioning & Heating for commercial or residential installation, upgrades, maintenance, or repair in Cocoa Beach and the surrounding Space Coast area, know that every aspect of your project will meet your highest expectation.  Bringing together top notch products, cutting-edge equipment, and the most extensively trained and experienced technicians, we deliver immediate and lasting solutions.  Trust your heating and cooling requirements to Kabran Air Conditioning & Heating and count on outstanding energy savings, reliable performance, and exceptional comfort.

We are so happy with the service and the unit installed. Carlos, the sales representative, was very attentive to our needs at the time. He knew exactly what we needed for our a/c concerns. Brandon Hayword, the a/c installer was amazing. I have never seen a technician so meticulous. Every detail was attended to. Poor guy worked from morning till 4:00 Am the next day. Never heard a complaint or wanted to go home and call it a night. Again, thank-you for the great service.
The contactor (relay) and start/run capacitor(s) (see illustration below) fail most often and are inexpensive. So it’s a safe bet to buy and install those parts right away, especially if your air conditioning service unit is older than five years. The condenser fan motor can also fail, but it runs about $150 — hold off buying that unless you’re sure that’s the culprit.

This type of furnace is fueled by liquid propane gas, which is burned to push hot air through your home. A pilot light ignites the burners within a combustion chamber, which push heat into the heat exchanger and eventually through your entire home. Repairing this type of furnace can be more expensive than its electric alternative. For example here are some common propane gas repairs and their costs:
Poorly maintained water cooling towers can promote the growth and spread of microorganisms,[56] such as Legionella pneumophila, the infectious agent responsible for Legionnaires' disease, or thermophilic actinomycetes. As long as the cooling tower is kept clean (usually by means of a chlorine treatment), these health hazards can be avoided or reduced. Excessive air conditioning can have a negative effect on skin, causing it to dry out, and can also cause dehydration.[citation needed]

Hospital operating theatres, in which air is filtered to high levels to reduce infection risk and the humidity controlled to limit patient dehydration. Although temperatures are often in the comfort range, some specialist procedures, such as open heart surgery, require low temperatures (about 18 °C, 64 °F) and others, such as neonatal, relatively high temperatures (about 28 °C, 82 °F).
Refrigeration air conditioning equipment usually reduces the absolute humidity of the air processed by the system. The relatively cold (below the dewpoint) evaporator coil condenses water vapor from the processed air, much like an ice-cold drink will condense water on the outside of a glass. Therefore, water vapor is removed from the cooled air and the relative humidity in the room is lowered. The water is usually sent to a drain or may simply drip onto the ground outdoors. The heat is ejected by the air conditioners condenser, which is located outside of the area being cooled. 
×