The Environmental Protection Agency (EPA) requires that all technicians who open a system containing a controlled refrigerant be certified to do so. There are four levels of certification, one of which is a “universal” certification to allow the HVAC technician to work on any type of equipment containing refrigerant. Your HVAC technician should be certified as “Level II Certified” at a minimum or, preferably, “Universal Certification” to work on your central air conditioner. Obtaining this certification information from your professional HVAC technician may be required in the event you are working with a realtor to sell your home. Costs for certification average $40 to $240.
As touched on by their name, heat pumps function by transferring heat energy indoors during the winter and outdoors from your home during the summer. They're often attached to air conditioning units, using the surrounding air to transfer energy. However, geothermal heat pumps and water source heat pumps are also available. The cost to repair a heat pump, again, depends on the specific problem. Replacing a faulty thermostat may cost up to $300 including labor, while a worn or damaged defrost control board can set you back up to $600. For more details on your potential repair costs using this heating source, visit our heat pump repair cost guide. 

Visit our one-of-a-kind showroom and explore the latest options on the market today. Check out sound decibel levels, heating and cooling capacity, learn how these systems work and compare old to new. The team from Strongsville Heating & Air Conditioning provides the products, guidance and service you can trust to surpass all your expectations. The weather is no match for our dedication to your satisfaction. At Strongsville Heating & Air Conditioning Customers Set the Goal….We Exceed It!
We had an exceptional experience with Gator Air, in particular Carlos. He presented us with quotes for different types of AC units, told us facts about said units and left us to make our decision. No high pressure sales. The installers were professional and cleaned up when they were through. A nice surprise was the 1 year free maintenance of the unit. We belonged to the Gator Club so to not have to pay it for the next year was an added bonus. Thank you GatorAir for making the experience an enjoyable one.
Absorption heat pumps are a kind of air-source heat pump, but they do not depend on electricity to power them. Instead, gas, solar power, or heated water is used as a main power source. An absorption pump dissolves ammonia gas in water, which gives off heat. Next, the water and ammonia mixture is depressurized to induce boiling, and the ammonia is boiled off, which absorbs heat from the outdoor air.[citation needed]

The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).


Air-source heat pumps are more popular in milder winter climates where the temperature is frequently in the range of 4–13 °C (40–55 °F), because heat pumps become inefficient in more extreme cold. This is because ice forms on the outdoor unit's heat exchanger coil, which blocks air flow over the coil. To compensate for this, the heat pump system must temporarily switch back into the regular air conditioning mode to switch the outdoor evaporator coil back to being the condenser coil, so that it can heat up and defrost. A heat pump system will therefore have a form of electric resistance heating in the indoor air path that is activated only in this mode in order to compensate for the temporary indoor air cooling, which would otherwise be uncomfortable in the winter.
For residential homes, some countries set minimum requirements for energy efficiency. In the United States, the efficiency of air conditioners is often (but not always) rated by the seasonal energy efficiency ratio (SEER). The higher the SEER rating, the more energy efficient is the air conditioner. The SEER rating is the BTU of cooling output during its normal annual usage divided by the total electric energy input in watt hours (W·h) during the same period.[33]
If your home is not heated using forced air, chances are a boiler will make sure you stay warm during cold nights. A hot water system delivers hot water through a network of pipes that run to every room in your house. The heating effect gets maximized through radiators. The most common issues with hot water heating tend to be not be major, but small problems that add up over time. Mineral deposits within the water tank, a pilot light malfunction, or an issue with a radiator itself can require professional repair. On average, you will pay between $183 and $582 for these problems. The exact amount will depend on the exact problem, as described in our boiler repair cost guide.
From winter's chill through the dog days of summer, our primary goal at Bailey's Comfort Services is to keep your home comfortable for you and your family. But, that's just the beginning. We also offer you peace of mind, ensuring your equipment operates safely. We help you save money on your fuel bills. And, we help deliver relief to those with allergies and those concerned with the quality of the air they breathe.
As a Carrier Factory Authorized Dealer, M and M, Heating & Cooling, Plumbing & Electrical is qualified to properly size and install the most technologically advanced and well-regarded heating, cooling, and air quality products on the market today. Our team is NATE-certified, factory trained, EPA certified, and regularly updated, ensuring the right solution to any challenge.
Because an air conditioner moves heat between the indoor coil and the outdoor coil, both must be kept clean. This means that, in addition to replacing the air filter at the evaporator coil, it is also necessary to regularly clean the condenser coil. Failure to keep the condenser clean will eventually result in harm to the compressor, because the condenser coil is responsible for discharging both the indoor heat (as picked up by the evaporator) and the heat generated by the electric motor driving the compressor.
At Horizon Services, we strive to provide all of our customers with the peace of mind that comes from knowing that you have a skilled team on-call for any AC emergencies that may arise. We have more than 300 fully stocked trucks ready to go at a moment's notice. Our Horizon technicians undergo rigorous training, including a mandatory 150 hours of training every year, to ensure that they're always up to date on the latest techniques and HVAC technology. Plus, we perform extensive background checks, including drug and criminal checks, on all of our employees so you don't have to worry about letting a stranger into your home when your AC breaks down in the middle of the night. When you're dealing with an air conditioning emergency, trust the experts at Horizon Services!
×