In 1906, Stuart W. Cramer of Charlotte was exploring ways to add moisture to the air in his textile mill. Cramer coined the term "air conditioning", using it in a patent claim he filed that year as an analogue to "water conditioning", then a well-known process for making textiles easier to process. He combined moisture with ventilation to "condition" and change the air in the factories, controlling the humidity so necessary in textile plants. Willis Carrier adopted the term and incorporated it into the name of his company.[10]
Strongsville Heating & Air Conditioning simplifies the challenges of keeping a perfectly comfortable home. We provide convenience, cost-savings, and reliability using top of the line products, premium materials, highly skilled technicians and exceptional customer service. Whether you need a new heating/cooling installation, replacement, retrofit, routine maintenance, trustworthy repair or air quality options, count on our team of NATE-certified technicians to eliminate stress and maximize comfort. We protect your busy schedule with flexible appointments, prompt arrival and mess free completion. Strongsville Heating & Air Conditioning is always available to you for Emergency Service, 24 hours a day, 365 days a year across Strongsville & Surrounding Areas.
For starters, once a year, vacuum out the area around the furnace’s blower. If possible, also slide out the fan unit, clean each fan blade with a toothbrush, and then vacuum with a brush attachment on a vacuum cleaner. While you’re at it, look for oil ports on the motor, normally located near the motor shaft. If the motor has these, apply two to three drops of non-detergent motor oil into each port (you may have to remove a cover plate to do this). Though most contemporary motors don’t require lubrication, do lubricate motors with oil ports once a year. For more about maintenance, see Maintenance Checklist for Central Heating Systems.
Consequently, this water must exit the air handler—typically through plastic pipe or a drain tube. That drain tube goes directly outside, often terminating near the compressor, or to a floor drain or to a small electric “condensate pump” located by the air handler. Where a condensate pump is used, it connects to a 1/2-inch vinyl or rubber tube that exits outdoors or to a drain.
We contacted GatorAC and have been pleased through the entire process of the purchase, installation and the daily functioning of the unit. We spoke to Angie to get information about the Trane AC. She arranged for Carlos Garcia to come to the house to determine the unit that would fit our needs. We made the choice between 3 units on Thursday and the unit was installed Friday. The Installation team, Willie Shaw and Gary Barber were the best. When they left everything was done, clean and clear and working great. We would recommend GatorAC for your AC needs.
In addition, if water is condensed in the room, the amount of heat previously needed to evaporate that water also is re-released in the room (the latent heat of vaporization). The dehumidification process is the inverse of adding water to the room with an evaporative cooler, and instead releases heat. Therefore, an in-room dehumidifier always will warm the room and reduce the relative humidity indirectly, as well as reducing the humidity directly by condensing and removing water.
Our fully trained and certified heating technicians have been repairing installing furnaces, heating systems and heat pumps in Smyrna and the Atlanta area since 1966.  We offer 24 hour emergency service for unexpected heating system break downs.  We can provide expert maintenance and repair on your current heating system or help you select a new, high-efficiency heating system from our wide range of furnaces.
Drug-screened and always dressed professionally in uniform, the team of heating and cooling technicians from Kabran Air Conditioning & Heating respects your time, property, and investment. Through organized project management and competitive pricing, we ensure a rewarding start-to-finish experience.  We offer free estimates on system upgrades, extended Emergency Service hours, and convenient and affordable maintenance plans.  When you take advantage of membership in the KABRAN Cool Club, you’ll benefit from superior savings, priority scheduling, and much more.  Let us protect your comfort, safety, and investment with regular inspection and meticulous tuning.
Finally, don't underestimate the thermostat as a potential reason why your furnace is not working. Everything on the heating unit itself may function perfectly, but your home still will not heat right if the console you use to set the temperature doesn't communicate your input. A faulty thermostat can either be due to the wall unit itself, or the wiring that connects it to your furnace. Average thermostat repair costs are between $108 and $282, including labor. Replacement costs, of course, depend on the thermostat you choose. Visit our thermostat repair cost guide to learn more about this type of issue. 

2) Keep your coils clean. The AC coils and fins on the outside of your unit need to be kept clean and clear of obstructions. Leaves and other debris sometimes accumulate around your unit. If obstructions are present, your unit must work harder to function than it should. You can clean your unit with a regular garden hose and a broom. Do not use a pressure washer, as the strong spray could cause harm to your system. A little bit of housekeeping in this regard goes far toward keeping your air conditioner working optimally. 
An important component of natural ventilation is air change rate or air changes per hour: the hourly rate of ventilation divided by the volume of the space. For example, six air changes per hour means an amount of new air, equal to the volume of the space, is added every ten minutes. For human comfort, a minimum of four air changes per hour is typical, though warehouses might have only two. Too high of an air change rate may be uncomfortable, akin to a wind tunnel which have thousands of changes per hour. The highest air change rates are for crowded spaces, bars, night clubs, commercial kitchens at around 30 to 50 air changes per hour.[17]
All consumer and property manager beware of this is not the old frymire anymore. they are under new ownership and with bunch rip-off tech! I am the property manager with a handyman and were unable to get the heat pump furnace relay replaced on time so I gave them another chance to do it base on good experience in previous. however, the tech used old school trick:telling me his truck dont have the relay and need to get the parts then will call me back. lone story short, we end up been charged for 290 for just a relay! and he even quoted us for a bad run capacitor for total 460!! we called them to provide a detail work invoice as usual and they never send to us so we end up to tell landlord that's how it is.. Huge mistake I ever made..don't trust them at all!!
Nobody wants to deal with a broken furnace in winter. Lucky for you, our Denver furnace repair specialists are available 7 days a week. Don’t face cold winter nights without a well functioning furnace. Contact us, your Denver furnace repair company so that we can diagnose the problem and set you up with a preventative maintenance package so we can catch problems before they occur. Click HERE to learn more about our furnace related services.

Your HVAC professional can also help you verify that your system is properly matched by providing you with an AHRI Certificate of Certified Product Performance upon request. The certificate verifies that the outdoor unit (condenser) and the indoor unit (evaporator) combination has been certified as a matched system by the Air Conditioning, Heating and Refrigeration Institute (AHRI). For higher efficiency systems, this certification may help you obtain a rebate from your utility or local municipality if you have to replace your unit in whole or in part. Not all areas offer a rebate, but your technician will likely be able to provide information about the certification process. Fees for performing this certification vary, but generally are relatively inexpensive.


The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).

For residential homes, some countries set minimum requirements for energy efficiency. In the United States, the efficiency of air conditioners is often (but not always) rated by the seasonal energy efficiency ratio (SEER). The higher the SEER rating, the more energy efficient is the air conditioner. The SEER rating is the BTU of cooling output during its normal annual usage divided by the total electric energy input in watt hours (W·h) during the same period.[33]
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
For residential homes, some countries set minimum requirements for energy efficiency. In the United States, the efficiency of air conditioners is often (but not always) rated by the seasonal energy efficiency ratio (SEER). The higher the SEER rating, the more energy efficient is the air conditioner. The SEER rating is the BTU of cooling output during its normal annual usage divided by the total electric energy input in watt hours (W·h) during the same period.[33]
CIBSE publishes several guides to HVAC design relevant to the UK market, and also the Republic of Ireland, Australia, New Zealand and Hong Kong. These guides include various recommended design criteria and standards, some of which are cited within the UK building regulations, and therefore form a legislative requirement for major building services works. The main guides are:

Our complaint-free A+ rating from the Better Business Bureau and Angie’s List Super Service Award evidences a longstanding tradition of customer satisfaction.  When you contact Kabran Air Conditioning & Heating for commercial or residential installation, upgrades, maintenance, or repair in Cocoa Beach and the surrounding Space Coast area, know that every aspect of your project will meet your highest expectation.  Bringing together top notch products, cutting-edge equipment, and the most extensively trained and experienced technicians, we deliver immediate and lasting solutions.  Trust your heating and cooling requirements to Kabran Air Conditioning & Heating and count on outstanding energy savings, reliable performance, and exceptional comfort.
The heat-exchanger cools the air that is being forced through it by the furnace blower. As the warm air comes in contact with this cool surface the water in the air condenses. By pulling the water molecules from the air. According to the psychometric chart[42] as relative humidity decreases in order to feel cool you will have to lower the temperature even more. A common way to counteract this effect is by installing a whole-home humidifier.[43] Similarly, installing a high efficient system this need to turn the temperature down wont have such and influence on your energy costs.
In the UK, the Ozone Regulations[63] came into force in 2000 and banned the use of ozone depleting HCFC refrigerants such as R22 in new systems. The Regulation banned the use of R22 as a "top-up" fluid for maintenance between 2010 (for virgin fluid) and 2015 (for recycled fluid). This means that equipment that uses R22 can still operate, as long as it does not leak. Although R22 is now banned, units that use the refrigerant can still be serviced and maintained.
In 1758, Benjamin Franklin and John Hadley, a chemistry professor at Cambridge University, conducted an experiment to explore the principle of evaporation as a means to rapidly cool an object. Franklin and Hadley confirmed that evaporation of highly volatile liquids (such as alcohol and ether) could be used to drive down the temperature of an object past the freezing point of water. They conducted their experiment with the bulb of a mercury thermometer as their object and with a bellows used to speed up the evaporation. They lowered the temperature of the thermometer bulb down to −14 °C (7 °F) while the ambient temperature was 18 °C (64 °F). Franklin noted that, soon after they passed the freezing point of water 0 °C (32 °F), a thin film of ice formed on the surface of the thermometer's bulb and that the ice mass was about 6 mm (1⁄4 in) thick when they stopped the experiment upon reaching −14 °C (7 °F). Franklin concluded: "From this experiment one may see the possibility of freezing a man to death on a warm summer's day."[9] 
×