Hello, We have a Hunter ceiling fan that no longer spins. It has power, as the light still works and when you push the remote you hear the clicking, like it's trying to engage, but the blades do not spin. Does this sound like a possible flywheel issue? I removed the Remote Receiver, part 85112-02, and apparently it's no longer available, but I don't think the receive is the problem. Any feedback would be welcome.

7) Schedule an annual tune-up with an HVAC professional. A trained HVAC technician can detect most problems before they become major ones. With a cost of around $100 for a routine maintenance call, the benefits will likely outweigh the costs by a considerable margin. A typical tune-up will include various tests to ensure your unit’s internal parts are functioning correctly, as well as a filter check, and a refrigerant charge if needed. Your technician will likely also clear the drain, and clean your unit thoroughly inside and out.


Furnaces and thermostats are not mix-and-match appliances. Using the wrong type of thermostat with a furnace will cause operating problems and can be dangerous. Although thermostats look similar, they are designed very differently. There are numerous types of heating systems and thermostat systems and they need to be coordinated for safe and proper operation. There are three types of thermostat systems used today: millivoltage, low voltage, and line voltage.​
In 1758, Benjamin Franklin and John Hadley, a chemistry professor at Cambridge University, conducted an experiment to explore the principle of evaporation as a means to rapidly cool an object. Franklin and Hadley confirmed that evaporation of highly volatile liquids (such as alcohol and ether) could be used to drive down the temperature of an object past the freezing point of water. They conducted their experiment with the bulb of a mercury thermometer as their object and with a bellows used to speed up the evaporation. They lowered the temperature of the thermometer bulb down to −14 °C (7 °F) while the ambient temperature was 18 °C (64 °F). Franklin noted that, soon after they passed the freezing point of water 0 °C (32 °F), a thin film of ice formed on the surface of the thermometer's bulb and that the ice mass was about 6 mm (1⁄4 in) thick when they stopped the experiment upon reaching −14 °C (7 °F). Franklin concluded: "From this experiment one may see the possibility of freezing a man to death on a warm summer's day."[9]
Your air conditioner can break down anytime, even on the unholiest of hours. That, however, is not a problem with Precision Air and Heating, since we offer 24-hour emergency service. Even if your AC conks out in the middle of an incredibly warm summer night, you won’t suffer for long if you call us ASAP. We promise to provide the best AC repair Phoenix AZ has available no matter what time you need it.
Whether you are in need of new installation, system replacement, seasonal maintenance, or prompt repair, M and M, Heating & Cooling, Plumbing & Electrical lives up to your highest expectations for quality, pricing, reliability, and quick turnaround on all projects.  And our commitment isn’t limited to regular business hours.  We’re always available when you need us, providing 24 hour Emergency Service across Longmont, Dacono, Frederick, Firestone, Mead, Erie & Johnstown, CO.  Trust the #1 Rated and Certified – A/C, Heating, and Plumbing Experts.
Variable-speed technology allows more energy saving potential and improved comfort levels throughout the home.  The ability of the system to automatically adjust speeds according to the needs of the home ensures the right amount of comfort control, right when you need it.  Outside temperatures rarely, if ever, require your HVAC system to operate at 100% capacity.  Variable-speed units determine optimal cooling needs and vary speeds in increments between 40% and 100%.  Not only does this tailor comfort, but by running at lower speeds and consuming less power, you’ll save a significant amount off monthly utility expenses.
As a Carrier Factory Authorized Dealer, M and M, Heating & Cooling, Plumbing & Electrical is qualified to properly size and install the most technologically advanced and well-regarded heating, cooling, and air quality products on the market today. Our team is NATE-certified, factory trained, EPA certified, and regularly updated, ensuring the right solution to any challenge.
ISO 16813:2006 is one of the ISO building environment standards.[32] It establishes the general principles of building environment design. It takes into account the need to provide a healthy indoor environment for the occupants as well as the need to protect the environment for future generations and promote collaboration among the various parties involved in building environmental design for sustainability. ISO16813 is applicable to new construction and the retrofit of existing buildings.[33]
Poorly maintained water cooling towers can promote the growth and spread of microorganisms,[56] such as Legionella pneumophila, the infectious agent responsible for Legionnaires' disease, or thermophilic actinomycetes. As long as the cooling tower is kept clean (usually by means of a chlorine treatment), these health hazards can be avoided or reduced. Excessive air conditioning can have a negative effect on skin, causing it to dry out, and can also cause dehydration.[citation needed]
Within the construction sector, it is the job of the building services engineer to design and oversee the installation and maintenance of the essential services such as gas, electricity, water, heating and lighting, as well as many others. These all help to make buildings comfortable and healthy places to live and work in. Building Services is part of a sector that has over 51,000 businesses and employs represents 2%-3% of the GDP.
In very dry climates, evaporative coolers, sometimes referred to as swamp coolers or desert coolers, are popular for improving coolness during hot weather. An evaporative cooler is a device that draws outside air through a wet pad, such as a large sponge soaked with water. The sensible heat of the incoming air, as measured by a dry bulb thermometer, is reduced. The temperature of the incoming air is reduced, but it is also more humid, so the total heat (sensible heat plus latent heat) is unchanged. Some of the sensible heat of the entering air is converted to latent heat by the evaporation of water in the wet cooler pads. If the entering air is dry enough, the results can be quite substantial.
Repairs—If something appears to be not working right with your heating and cooling, a professional will examine the whole health of your system. It’s easy to hop on the internet and research information to find our own conclusions, but there could be an additional component or reason why your system isn’t working properly that isn’t clear or recognizable. Consider our own health concerns—you might check out your symptoms online to try and draw your conclusions, but it’s always best to make an appointment with a doctor to receive an expert opinion.
This job involves removing the access panel, loosening a couple of bolts that hold the blower motor at the proper tension, and adjusting its distance or realigning the belt. In many cases, it’s a good idea to remove the belt and buy a replacement at a home center. Last, when reinstalling the belt, be careful not to over-tighten it; this can wear out the motor bearings.

The Environmental Protection Agency (EPA) requires that all technicians who open a system containing a controlled refrigerant be certified to do so. There are four levels of certification, one of which is a “universal” certification to allow the HVAC technician to work on any type of equipment containing refrigerant. Your HVAC technician should be certified as “Level II Certified” at a minimum or, preferably, “Universal Certification” to work on your central air conditioner. Obtaining this certification information from your professional HVAC technician may be required in the event you are working with a realtor to sell your home. Costs for certification average $40 to $240.
Reinstall the access panel and disconnect block. Turn on the circuit breaker and furnace switch. Then set the thermostat to a lower temperature and wait for the AC to start (see “Be Patient at Startup,” below). The compressor should run and the condenser fan should spin. If the compressor starts but the fan doesn’t, the fan motor is most likely shot. Shut off the power and remove the screws around the condenser cover. Lift the cover and remove the fan blade and motor (photo 7). Reinstall the blade and secure the cover. Then repower the unit and see if the fan starts. If it doesn’t, you’ve given it your best shot—it’s time to call a pro.
ISO 16813:2006 is one of the ISO building environment standards.[32] It establishes the general principles of building environment design. It takes into account the need to provide a healthy indoor environment for the occupants as well as the need to protect the environment for future generations and promote collaboration among the various parties involved in building environmental design for sustainability. ISO16813 is applicable to new construction and the retrofit of existing buildings.[33]

Cleaning the debris that builds up on your filters will aid with the flow of air. When your air filter is clogged, your air handler must work harder to compensate for the blockage of air flow. In addition to driving up your utility bill, the reduced air flow through your heating and cooling system can cause your heat exchanger to overheat and shut off too quickly.    
Our fully trained and certified heating technicians have been repairing installing furnaces, heating systems and heat pumps in Smyrna and the Atlanta area since 1966.  We offer 24 hour emergency service for unexpected heating system break downs.  We can provide expert maintenance and repair on your current heating system or help you select a new, high-efficiency heating system from our wide range of furnaces.
We relocate frequently and one of the biggest hassles of relocating to new areas is finding reputable companies that send qualified technicians to perform work when you need it, whether for annual preventative maintenance or during a house emergency. We’ve been through the process several times and always dread researching and trying new companies. This was our first HVAC call here in northern Virginia. We are in new construction and chose not to use the builder’s sub-contractor for a technician call but looked through Carrier’s website for a local business. Jeremy Garner with HVAC Unlimited responded to our service request the morning following our call. I shadowed him performing work and he was patient while I peppered him with questions. He helped expand my HVAC knowledge in order to be a better property owner of our systems. He performed the work we thought was necessary, in a timely and professional manner, and gave us options for future annual maintenance. HVAC Unlimited is definitely on our list of go-to contractors.
I don’t normally rate a company 5 stars, because nobody is perfect, but these guys did a wonderful job. Carlos their sales person was knowledgeable and courteous. The office staff was extremely helpful and very friendly and the installers were on time and did a great job. Even the county inspector said, “Wow, these guys did a great job!” That’s the first time I’ve ever heard an inspector give his personal opinion on a job. I’m sixty one and I’ve had to have a lot of systems replace over the years. Well done everyone at Gator Air. Your the best! If your looking to replace your AC system, look no further.
Any concern with your cooling system, however minor, is worth checking out.  NATE-certified technicians can quickly identify the problem and prevent more extensive and costly damage.  Catching defects quickly is the key to cost-effective repairs.  Elevated operational noise such as grinding, screeching, or wheezing is more than aggravating.  Think of those sounds as warning bells.  They’re an indication of component failure.  Listen to what they’re telling you and call for professional assistance.  Worn or misaligned belts are easily repaired.  Strange smells from contaminants such as mold or mildew are best handled before allergens enter breathing air, diminish airflow, and block the coil.  Temperature swings, unstable humidity, or extended run times are all signs of bigger problems on the way.  Call Ferran Services at 407-422-3551 (Orlando) or 386-322-6168 (Volusia), and our licensed technicians will perform a complete system check, ensuring safe, efficient and reliable operation.

As a technical industry, the heating and cooling field is associated with annual advances. New energies make our industry an exciting place to work. Our team thrives on keeping up to date with all changes in the HVAC field. We are here to share our knowledge with each customer. When you are ready to update your HVAC system, we can help you select the ideal system for your home.
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
×