Whether you are in need of new installation, system replacement, seasonal maintenance, or prompt repair, M and M, Heating & Cooling, Plumbing & Electrical lives up to your highest expectations for quality, pricing, reliability, and quick turnaround on all projects.  And our commitment isn’t limited to regular business hours.  We’re always available when you need us, providing 24 hour Emergency Service across Longmont, Dacono, Frederick, Firestone, Mead, Erie & Johnstown, CO.  Trust the #1 Rated and Certified – A/C, Heating, and Plumbing Experts.
Free cooling systems can have very high efficiencies, and are sometimes combined with seasonal thermal energy storage so that the cold of winter can be used for summer air conditioning. Common storage mediums are deep aquifers or a natural underground rock mass accessed via a cluster of small-diameter, heat-exchanger-equipped boreholes. Some systems with small storages are hybrids, using free cooling early in the cooling season, and later employing a heat pump to chill the circulation coming from the storage. The heat pump is added-in because the storage acts as a heat sink when the system is in cooling (as opposed to charging) mode, causing the temperature to gradually increase during the cooling season.
In 1995, Germany made CFC refrigerators illegal.[22] DuPont and other companies blocked the refrigerant in the U.S. with the U.S. EPA, disparaging the approach as "that German technology".[21][23] Nevertheless, in 2004, Greenpeace worked with multinational corporations like Coca-Cola and Unilever, and later Pepsico and others, to create a corporate coalition called Refrigerants Naturally!.[22][24] Then, four years later, Ben & Jerry's of Unilever and General Electric began to take steps to support production and use in the U.S.[25] In 2011 the EPA decided in favor of the ozone- and climate-safe refrigerant for U.S. manufacture.[17][26][27]
We were visiting our Arizona home from New York, when on one of the hottest days in August the air conditioning was not working. We called Precision & James Shelton worked to get the air up & running in no time. He was courteous & sympathetic, working hard to repair our central air…we have a warranty & Precision stands behind their work, they are available 24/7… Thank you!
Air conditioning can also be provided by a process called free cooling which uses pumps to circulate a coolant (typically water or a glycol mix) from a cold source, which in turn acts as a heat sink for the energy that is removed from the cooled space. Common storage media are deep aquifers or a natural underground rock mass accessed via a cluster of small-diameter boreholes, equipped with heat exchanger. Some systems with small storage capacity are hybrid systems, using free cooling early in the cooling season, and later employing a heat pump to chill the circulation coming from the storage. The heat pump is added because the temperature of the storage gradually increases during the cooling season, thereby declining its effectiveness.
When natural gas, propane or heating oil are burned in a furnace, the resulting hot combustion gasses by burning natural gas, propane or heating oil circulate through a heat exchanger. The heat exchanger will, in turn, release that heat to be circulated by the furnace’s blower. The flue gas then travels through the flue vent, which carries the gas outside of the home. When a heat exchanger is cracked, it generally will require a complete system replacement. That is one of the reasons why we highly recommend annual preventive maintenance on your home’s furnace – this preventative furnace inspection and maintenance can greatly prolong the life of your home heating system.
The use of furnaces, space heaters, and boilers as a method of indoor heating could result in incomplete combustion and the emission of carbon monoxide, nitrogen oxides, formaldehyde, volatile organic compounds, and other combustion byproducts. Incomplete combustion occurs when there is insufficient oxygen; the inputs are fuels containing various contaminants and the outputs are harmful byproducts, most dangerously carbon monoxide, which is a tasteless and odorless gas with serious adverse health effects.[14]
A dehumidifier is an air-conditioner-like device that controls the humidity of a room or building. It is often employed in basements which have a higher relative humidity because of their lower temperature (and propensity for damp floors and walls). In food retailing establishments, large open chiller cabinets are highly effective at dehumidifying the internal air. Conversely, a humidifier increases the humidity of a building.
Some systems include an "economizer mode", which is sometimes called a "free-cooling mode". When economizing, the control system will open (fully or partially) the outside air damper and close (fully or partially) the return air damper. This will cause fresh, outside air to be supplied to the system. When the outside air is cooler than the demanded cool air, this will allow the demand to be met without using the mechanical supply of cooling (typically chilled water or a direct expansion "DX" unit), thus saving energy. The control system can compare the temperature of the outside air vs. return air, or it can compare the enthalpy of the air, as is frequently done in climates where humidity is more of an issue. In both cases, the outside air must be less energetic than the return air for the system to enter the economizer mode.
Kabran Air Conditioning & Heating has been providing homeowners throughout Cocoa Beach FL, Satellite Beach FL, Cape Canaveral FL, Rockledge FL, Melbourne FL, Merritt Island FL, Viera FL, Indian Harbour Beach FL with reliable residential heating and air conditioning services since 1984. Whether you need installation, maintenance, or repair, our team of heating and cooling specialists has the experience and knowledge to leave you with optimum comfort every time. We’re dedicated to your satisfaction and the health and safety of your indoor environment. We offer trusted Carrier brand heating and air conditioning products, and an expertise that goes above and beyond for all our HVAC services. Contact our trustworthy team today and get the heating and air conditioning service you deserve!
In the United States, HVAC engineers generally are members of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), EPA Universal CFC certified (for installation and service of CFC HVAC devices), or locally engineer certified such as a Special to Chief Boilers License issued by the state or, in some jurisdictions, the city. ASHRAE is an international technical society for all individuals and organizations interested in HVAC. The Society, organized into regions, chapters, and student branches, allows exchange of HVAC knowledge and experiences for the benefit of the field's practitioners and the public. ASHRAE provides many opportunities to participate in the development of new knowledge via, for example, research and its many technical committees. These committees typically meet twice per year at the ASHRAE Annual and Winter Meetings. A popular product show, the AHR Expo, is held in conjunction with each winter meeting. The Society has approximately 50,000 members and has headquarters in Atlanta, Georgia.
All modern air conditioning systems, even small window package units, are equipped with internal air filters. These are generally of a lightweight gauzy material, and must be replaced or washed as conditions warrant. For example, a building in a high dust environment, or a home with furry pets, will need to have the filters changed more often than buildings without these dirt loads. Failure to replace these filters as needed will contribute to a lower heat exchange rate, resulting in wasted energy, shortened equipment life, and higher energy bills; low air flow can result in iced-over evaporator coils, which can completely stop air flow. Additionally, very dirty or plugged filters can cause overheating during a heating cycle, and can result in damage to the system or even fire.
Our furnace quit lighting yesterday. I called Cool Tech around 7pm and they offered to come out after hours, but I chose to set up an appointment today. The technician John called me at 7:30am and was there about 8am as promised. He was very courteous and replaced the igniter quickly. The heater is back to working properly. This is my second time hiring Cool Tech and they will continue to be my go-to heating and air conditioning guys.

Natural ventilation is the ventilation of a building with outside air without using fans or other mechanical systems. It can be via operable windows, louvers, or trickle vents when spaces are small and the architecture permits. In more complex schemes, warm air is allowed to rise and flow out high building openings to the outside (stack effect), causing cool outside air to be drawn into low building openings. Natural ventilation schemes can use very little energy, but care must be taken to ensure comfort. In warm or humid climates, maintaining thermal comfort solely via natural ventilation might not be possible. Air conditioning systems are used, either as backups or supplements. Air-side economizers also use outside air to condition spaces, but do so using fans, ducts, dampers, and control systems to introduce and distribute cool outdoor air when appropriate.
Variable-speed technology allows more energy saving potential and improved comfort levels throughout the home.  The ability of the system to automatically adjust speeds according to the needs of the home ensures the right amount of comfort control, right when you need it.  Outside temperatures rarely, if ever, require your HVAC system to operate at 100% capacity.  Variable-speed units determine optimal cooling needs and vary speeds in increments between 40% and 100%.  Not only does this tailor comfort, but by running at lower speeds and consuming less power, you’ll save a significant amount off monthly utility expenses.
We are committed to providing high quality same-day furnace repair in Denver and strive for 100% customer satisfaction, 7 days a week. All our specialists are drug tested and background checked and our techs use shoe covers and floor mats to keep all homes the same way they found them. You won’t find an equal level of commitment from anyone else compared to our Denver furnace repair specialists.

You might guess it from the name: the heat exchanger is the part of your furnace that actually heats the air your blower motor pushes through the furnace. It consists of a chamber in which the heat energy produced by natural or propane gas is transferred to the forced air. At the same time, this part also includes a vent through which the gases themselves are safely removed from the unit and the air that enters your home. Because of these gases, a problem with your heat exchanger needs to be dealt with promptly. Over time, cracks in the exchanger can result in carbon monoxide leaks. Taking care of the problem once again means understanding the existence of a range: repairing your heat exchanger can cost as little as $100, but a full replacement may cost up to $1,200.
Furnaces and thermostats are not mix-and-match appliances. Using the wrong type of thermostat with a furnace will cause operating problems and can be dangerous. Although thermostats look similar, they are designed very differently. There are numerous types of heating systems and thermostat systems and they need to be coordinated for safe and proper operation. There are three types of thermostat systems used today: millivoltage, low voltage, and line voltage.​

Cut down on energy costs and prevent damage to your furnace by addressing a gas furnace that's overactive or short cycling. Besides the need for consistently comfortable temperatures, this issue could cause long-term safety issues to your home, making it very important to address. From a faulty thermostat to a dirty filter, there are several possible causes to investigate.


Packaged terminal air conditioner (PTAC) systems are also known as wall-split air conditioning systems.[36] They are ductless systems. PTACs, which are frequently used in hotels, have two separate units (terminal packages), the evaporative unit on the interior and the condensing unit on the exterior, with an opening passing through the wall and connecting them. This minimizes the interior system footprint and allows each room to be adjusted independently. PTAC systems may be adapted to provide heating in cold weather, either directly by using an electric strip, gas, or other heater, or by reversing the refrigerant flow to heat the interior and draw heat from the exterior air, converting the air conditioner into a heat pump. While room air conditioning provides maximum flexibility, when used to cool many rooms at a time it is generally more expensive than central air conditioning.
Window unit air conditioners are installed in an open window. The interior air is cooled as a fan blows it over the evaporator. On the exterior the heat drawn from the interior is dissipated into the environment as a second fan blows outside air over the condenser. A large house or building may have several such units, allowing each room to be cooled separately.

The cost to replace your entire unit is around $4,000. That expense can range from $2,500 to $5,900, depending on the type and brand of furnace you choose. Brands particularly have an impact on that price. A Goodman electric furnace, will only cost about $2,100 for the unit and labor. On the other hand, a Trane oil furnace may cost up to $9,000 all things considered. Our Furnace Installation Cost Guide can give you a better idea on both the general cost and the differences for brands like Amana, Bryant, Coleman, and others. The brand also plays into the repair cost for your furnace. Especially the prices of individual parts can change; a York heat exchanger, for example, can cost up to $1,900, while the same component from Heil will cost as little as $400.
Mr. Plumber provides fast, expert plumbing service to Smyrna, GA and is here for you with 24 hour emergency plumbing service. Our licensed and certified plumbers can tackle all your plumbing jobs including sink & faucet repair, toilet repair & replacement, water line repair & replacement, drain cleaning, bathtubs & shower installation and repair, water heater installation, sewer repair, backflow prevention and more. Our professional plumbers will respect your time, home and business. You approve the price before we perform our plumbing work and your satisfaction is guaranteed! Give us a call today for:
AC air handler squealing or grinding noises. Though most air handlers have direct-drive motors, some older units may be belt-driven. Squealing sounds from a belt-drive air handler generally occur when the belt that connects the motor to the blower slips. In most cases, the belt is improperly aligned or worn and needs replacement. Follow the instructions above under Air Conditioner Not Blowing Air and refer to your owner’s manual.
Most Michigan HVAC repair companies will often charge a “Travel Charge” or “Diagnosis Fee.” Randazzo calls this fee simply, a “Service Call Fee.” This will be the minimum cost of the repair. It is not recommended to judge a company on how expensive or how cheap their service rates are. In most cases, with larger companies the rates will be higher. This is not because they may have more overhead but simply because of the quality and preparedness of the service that will be preformed.
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
×