Recent Review: Frymire did a complete A/C and Furnace install on my property in May 2013.  I had 5 companies bid the job and what sold me on them was their honesty and responsiveness, as well as a fair price.  They were not the lowest, but were willing to negotiate on some unknown repair issues with my duct work, etc.  The team was punctual and very professional, taking extra pains to wear protective footwear on my hardwood floors.  The foreman on the job kept me up to speed about the install throughout the day.   They started at 9 a.m. and were finished and out by 6pm.  I recently had them return for the yearly check-up on my A/C.  The tech was efficient and very professional.  I would highly recommend their service. 
SEER is related to the coefficient of performance (COP) commonly used in thermodynamics and also to the Energy Efficiency Ratio (EER). The EER is the efficiency rating for the equipment at a particular pair of external and internal temperatures, while SEER is calculated over a whole range of external temperatures (i.e., the temperature distribution for the geographical location of the SEER test). SEER is unusual in that it is composed of an Imperial unit divided by an SI unit. The COP is a ratio with the same metric units of energy (joules) in both the numerator and denominator. They cancel out, leaving a dimensionless quantity. Formulas for the approximate conversion between SEER and EER or COP are available.[34]
The selection of the working fluids (refrigerants) has a significant impact not only on the performance of the air conditioners but on the environment as well. Most refrigerants used for air conditioning contribute to global warming, and many also deplete the ozone layer.[60] CFCs, HCFCs, and HFCs are potent greenhouse gases when leaked to the atmosphere.

We had an exceptional experience with Gator Air, in particular Carlos. He presented us with quotes for different types of AC units, told us facts about said units and left us to make our decision. No high pressure sales. The installers were professional and cleaned up when they were through. A nice surprise was the 1 year free maintenance of the unit. We belonged to the Gator Club so to not have to pay it for the next year was an added bonus. Thank you GatorAir for making the experience an enjoyable one.
Because an air conditioner moves heat between the indoor coil and the outdoor coil, both must be kept clean. This means that, in addition to replacing the air filter at the evaporator coil, it is also necessary to regularly clean the condenser coil. Failure to keep the condenser clean will eventually result in harm to the compressor, because the condenser coil is responsible for discharging both the indoor heat (as picked up by the evaporator) and the heat generated by the electric motor driving the compressor.
If you have forced-air cooling but there’s still a room that’s hotter than all the rest, a duct or vent booster fan can increase the flow of cool air into that room. Two types of booster fans are available. An in-line duct booster fan (shown) fits inside the duct of the room you’re trying to cool. You mount the fan near the outlet and it automatically kicks on when your cooling system runs.
Air conditioning is common in the US, with 88% of new single-family homes constructed in 2011 including air conditioning, ranging from 99% in the South to 62% in the West.[51] In Canada, air conditioning use varies by province. In 2013, 55% of Canadian households reported having an air conditioner, with high use in Manitoba (80%), Ontario (78%), Saskatchewan (67%), and Quebec (54%) and lower use in Prince Edward Island (23%), British Columbia (21%), and Newfoundland and Labrador (9%).[52] In Europe, home air conditioning is generally less common. Southern European countries such as Greece have seen a wide proliferation of home air-conditioning units in recent years.[53] In another southern European country, Malta, it is estimated that around 55% of households have an air conditioner installed.[54] In India AC sales have dropped by 40%[clarification needed] due to higher costs and stricter energy efficiency regulations.[55]
HVAC repair technicians are properly qualified to take care of anything that relates to installing, maintaining or repairing your heating, air conditioning and refrigeration systems. Our professionals have gone through rigorous training and certification and all our technicians and equipment installers are NATE-certified, which involves demanding testing and indicates a solid understanding of the industry. 

An air conditioning system, or a standalone air conditioner, provides cooling and humidity control for all or part of a building. Air conditioned buildings often have sealed windows, because open windows would work against the system intended to maintain constant indoor air conditions. Outside, fresh air is generally drawn into the system by a vent into the indoor heat exchanger section, creating positive air pressure. The percentage of return air made up of fresh air can usually be manipulated by adjusting the opening of this vent. Typical fresh air intake is about 10%.


We happily offer all of our services in St Marys county. We view our neighbors in St. Mary’s county as important and valuable as our friends in Calvert. If you live in St Marys and you’re not sure if we can help you with your specific problem, please don’t hesitate to contact us and find out! We value all inquiries and our eager to help and assist our neighbors throughout all of Southern Maryland.
When a family chooses to work with Brothers Plumbing Heating And Electric they will not be disappointed. We are able to work on a very tight schedule and we know just what it takes to service a furnace. There is no doubt about it, a family does well to look into Brothers Plumbing Heating and Electric because we are truly the best Aurora furnace repair company. To learn more about heating and cooling systems, just give this page a visit today!
Replacing a capacitor is easy. Just take a photo of the wires before disconnecting anything (you may need a reference later on). Then discharge the stored energy in the old capacitor (Photo 4). Use needle-nose pliers to pluck one wire at a time from the old capacitor and snap it onto the corresponding tab of the new capacitor. The female crimp connectors should snap tightly onto the capacitor tabs. Wiggle each connector to see if it’s tight. If it’s not, remove the connector and bend the rounded edges of it so it makes a tighter fit on the tab. When you’ve swapped all the wires, secure the new capacitor (Photo 5).
×