The liquid refrigerant is returned to another heat exchanger where it is allowed to evaporate, hence the heat exchanger is often called an evaporating coil or evaporator. As the liquid refrigerant evaporates it absorbs energy (heat) from the inside air, returns to the compressor, and repeats the cycle. In the process, heat is absorbed from indoors and transferred outdoors, resulting in cooling of the building.

If you have forced-air cooling but there’s still a room that’s hotter than all the rest, a duct or vent booster fan can increase the flow of cool air into that room. Two types of booster fans are available. An in-line duct booster fan (shown) fits inside the duct of the room you’re trying to cool. You mount the fan near the outlet and it automatically kicks on when your cooling system runs.

Central home air conditioner service systems consist of two major components: a condensing unit that sits outside your house, and the evaporator coil (often referred to as an A-coil) that sits in the plenum of your furnace or air handler. The refrigerant in the A-coil picks up the heat from your home and moves it to the outdoor condensing unit. The condensing unit fan blows outside air through the condensing coil to remove the heat. The condensing unit houses the three parts replaceable by a DIYer: the contactor, the start/run capacitor(s) and the condenser fan motor. The condensing unit also houses the compressor, but only a pro can replace that. The A-coil has no parts that can be serviced by a DIYer.
Here at Brothers Plumbing, Heating, and Electric, we have a Home Care Club that provides members with many benefits. These benefits include: 2 year warranty on all work (drain work is excluded), transferable club membership, no “show up” fees, priority service, 10% discount on repairs, quarterly newsletters, carefree scheduling (we will contact you and remind you when you need service), 2 free furnace/air conditioner filter changes, exclusive coupons, quarterly drawings, 4 on-going safety checks, and a 100% satisfaction guarantee. So if you’d like to join our Home Care Club, then give us a call or click here today.
Vredevoogd Heating & Cooling technicians routinely assist our customers to figure out when it’s time to upgrade their Heating or Cooling system. Naturally, repairs are part of routine maintenance over the years. However, new models can save homeowners in a big way on energy expenses with their energy-efficient makeup. When you are ready to get a new system, we will do a careful check of your energy needs so that you can select the ideal system for your home’s needs. The wrong HVAC system for your home is a 15 year mistake that no one should have to afford. We install the right system for your home. Moreover, we offer guarantees that you won’t find just anywhere else. If your new installation isn’t right for your home, we’ll remove it free of charge at any time within that first year and refund 100% of your money. Our customers are burdened with no risks. We take on the risk because we are that sure of our expertise. We back our work with the strongest warranties in the field. In fact, we offer a wide array of warranties to provide you with the peace of mind you deserve as a valued Vredevoogd Heating & Cooling Grand Rapids MI customer.
We’ve proudly represented the very best Atlanta has to offer in superior service for 50 years. In that time, we’ve accumulated all it takes and more to bring you the best emergency heating and air conditioning repair services possible. Story after story, we deliver smiles! If you’re looking for a reliable company that provides 24-hour AC repair, don’t hesitate to contact us right away—770-913-6412!
The fan limit switch controls the furnace blower. The fan limit switch has three settings: “Fan On”, “Fan Off”, and “Limit”. In the “Fan Off” setting, the blower will only operate if there is warm air in the plenum to prevent cool air from blowing into the home. The “Fan On” setting will keep the blower operating even after the burner has shutdown, making sure that all of the hot air produced is circulated. The “Limit” setting is a safety control that will turn the burner off in the rare event that the air in the warm air plenum reaches an unsafe temperature. This may be the case if ducts are blocked or if the system controls are malfunctioning.
Furnaces and thermostats are not mix-and-match appliances. Using the wrong type of thermostat with a furnace will cause operating problems and can be dangerous. Although thermostats look similar, they are designed very differently. There are numerous types of heating systems and thermostat systems and they need to be coordinated for safe and proper operation. There are three types of thermostat systems used today: millivoltage, low voltage, and line voltage.​
In the case of heated water or steam, piping is used to transport the heat to the rooms. Most modern hot water boiler heating systems have a circulator, which is a pump, to move hot water through the distribution system (as opposed to older gravity-fed systems). The heat can be transferred to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be mounted on walls or installed within the floor to produce floor heat.

This job involves removing the access panel, loosening a couple of bolts that hold the blower motor at the proper tension, and adjusting its distance or realigning the belt. In many cases, it’s a good idea to remove the belt and buy a replacement at a home center. Last, when reinstalling the belt, be careful not to over-tighten it; this can wear out the motor bearings.


Furnaces and thermostats are not mix-and-match appliances. Using the wrong type of thermostat with a furnace will cause operating problems and can be dangerous. Although thermostats look similar, they are designed very differently. There are numerous types of heating systems and thermostat systems and they need to be coordinated for safe and proper operation. There are three types of thermostat systems used today: millivoltage, low voltage, and line voltage.​
AC units and thermostats have built-in delay features when they’re shut down and then repowered. The delay can be as long as 10 minutes. And, if you’ve subscribed to an energy-saving device from your local power utility, the unit can take even longer to reset. If you’ve installed the parts shown and reinstalled the disconnect block, repowered the circuit breaker, turned on the switch at the furnace, moved the thermostat to AC mode and lowered the temperature below the indoor temperature, and the unit doesn’t fire up after 30 minutes, it’s time to call a pro.

The selection of indoor units has one restriction: their total power should not exceed the capacity of the outdoor unit. In practice, however, it is very common to see a multi-split system with a total capacity of indoor units greater than the outdoor capacity by at least 20%. However, it is wrong to expect better performance when all indoor units are turned on at the same time, since the total capacity of the whole system is limited by the capacity of the outdoor unit. Simply put, the outdoor unit will distribute all its power to all operating indoor units in such a way that some of the rooms may not have a very comfortable temperature level. However, the calculation of the total power is not simple, since it takes into account not only the nominal power of the units, but also the cooling capacity, heating, dehumidification, humidification, venting, etc.


The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
Though Harrison had commercial success establishing a second ice company back in Sydney in 1860, he later entered the debate over how to compete against the American advantage of ice-refrigerated beef sales to the United Kingdom. He wrote: "Fresh meat frozen and packed as if for a voyage, so that the refrigerating process may be continued for any required period", and in 1873 prepared the sailing ship Norfolk for an experimental beef shipment to the United Kingdom. His choice of a cold room system instead of installing a refrigeration system upon the ship itself proved disastrous when the ice was consumed faster than expected.[citation needed]
Free cooling systems can have very high efficiencies, and are sometimes combined with seasonal thermal energy storage so that the cold of winter can be used for summer air conditioning. Common storage mediums are deep aquifers or a natural underground rock mass accessed via a cluster of small-diameter, heat-exchanger-equipped boreholes. Some systems with small storages are hybrids, using free cooling early in the cooling season, and later employing a heat pump to chill the circulation coming from the storage. The heat pump is added-in because the storage acts as a heat sink when the system is in cooling (as opposed to charging) mode, causing the temperature to gradually increase during the cooling season.
The Chartered Institution of Building Services Engineers is a body that covers the essential Service (systems architecture) that allow buildings to operate. It includes the electrotechnical, heating, ventilating, air conditioning, refrigeration and plumbing industries. To train as a building services engineer, the academic requirements are GCSEs (A-C) / Standard Grades (1-3) in Maths and Science, which are important in measurements, planning and theory. Employers will often want a degree in a branch of engineering, such as building environment engineering, electrical engineering or mechanical engineering. To become a full member of CIBSE, and so also to be registered by the Engineering Council UK as a chartered engineer, engineers must also attain an Honours Degree and a master's degree in a relevant engineering subject.
If your AC system is in need of replacement, the national average air conditioner installation costs range from $2,930 to $3,670. Costs can vary greatly depending on whether you are replacing a wall or window unit or a central air system. A central air system is connected to ductwork that runs throughout your house and pumps cooled air into your various rooms via vents and registers. A central air conditioning system is far more costly than wall or window units. Selecting a central AC system that has a high seasonal energy-efficiency ratio (SEER) will likely lower both your carbon footprint and your utility bill. The type of AC system you select, where you live in the country, and the regional costs of HVAC work, duct removal and replacement, and ductwork repairs that are needed are some of the main factors that affect the cost of new air conditioner installation. Here are some examples of average costs for installing forced-air systems.
Most Michigan HVAC repair companies will often charge a “Travel Charge” or “Diagnosis Fee.” Randazzo calls this fee simply, a “Service Call Fee.” This will be the minimum cost of the repair. It is not recommended to judge a company on how expensive or how cheap their service rates are. In most cases, with larger companies the rates will be higher. This is not because they may have more overhead but simply because of the quality and preparedness of the service that will be preformed.

Modern air conditioning systems are not designed to draw air into the room from the outside, they only recirculate the increasingly cool air on the inside. Because this inside air always has some amount of moisture suspended in it, the cooling portion of the process always causes ambient warm water vapor to condense on the cooling coils and to drip from them down onto a catch tray at the bottom of the unit from which it must then be routed outside, usually through a drain hole. As this moisture has no dissolved minerals in it, it will not cause mineral buildup on the coils. This will happen even if the ambient humidity level is low. If ice begins to form on the evaporative fins, it will reduce circulation efficiency and cause the development of more ice, etc. A clean and strong circulatory fan can help prevent this, as will raising the target cool temperature of the unit's thermostat to a point that the compressor is allowed to turn off occasionally. A failing thermistor may also cause this problem. Refrigerators without a defrost cycle may have this same issue. Dust can also cause the fins to begin blocking air flow with the same undesirable result: ice.
2) Keep your coils clean. The AC coils and fins on the outside of your unit need to be kept clean and clear of obstructions. Leaves and other debris sometimes accumulate around your unit. If obstructions are present, your unit must work harder to function than it should. You can clean your unit with a regular garden hose and a broom. Do not use a pressure washer, as the strong spray could cause harm to your system. A little bit of housekeeping in this regard goes far toward keeping your air conditioner working optimally. 

Our team of fully licensed and insured technicians each draw from between ten and thirty years of industry experience and share our unwavering dedication to customer service.  Entirely NATE-certified, our installation and service department has completed rigorous testing, and are exceptionally qualified to handle even the most complex HVAC challenges.  NATE (North American Technician Excellence) is the only nationwide certification program that is supported by the entire industry, and of all third-party certifications, has the lowest pass rate.


Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
Air conditioning makes deep plan buildings feasible, for otherwise they would have to be built narrower or with light wells so that inner spaces received sufficient outdoor air via natural ventilation. Air conditioning also allows buildings to be taller, since wind speed increases significantly with altitude making natural ventilation impractical for very tall buildings.[citation needed] Comfort applications are quite different for various building types and may be categorized as:

The belt should slip right into place. If it seems to be too tight or difficult to set in place, it may be necessary to adjust the motor mount to provide more slack. Then you can re-tighten the tension once the belt is in place. Check the manufacturer’s specifications for proper tension—in most cases, the belt should deflect about an inch when you press down on it.
The summers here in Alexandria can range from almost pleasant to downright brutal. And you know as well as we do that it’s those latter days when your central AC or heat pump will decide to go down! But you don’t have to seek solace at the Waterfront or over at Cameron Run Regional Park. The secret to restoring your comfort lies with the certified specialists at HVAC & Plumbing Unlimited!

Repairs—If something appears to be not working right with your heating and cooling, a professional will examine the whole health of your system. It’s easy to hop on the internet and research information to find our own conclusions, but there could be an additional component or reason why your system isn’t working properly that isn’t clear or recognizable. Consider our own health concerns—you might check out your symptoms online to try and draw your conclusions, but it’s always best to make an appointment with a doctor to receive an expert opinion.


In addition to the information below, see these two articles for the general care and maintenance of your air conditioner: Preparing Your Air Conditioner for Summer and How to Replace Furnace & AC Filters. Most noteworthy, you should replace the filters at least twice a year, before the heating and cooling seasons. For information on furnace problems, please see Furnace Not Working.
In the most general sense, air conditioning can refer to any form of technology that modifies the condition of air (heating, (de-) humidification, cooling, cleaning, ventilation, or air movement). In common usage, though, "air conditioning" refers to systems which cool air. In construction, a complete system of heating, ventilation, and air conditioning is referred to as HVAC.[3]
×