The Environmental Protection Agency (EPA) requires that all technicians who open a system containing a controlled refrigerant be certified to do so. There are four levels of certification, one of which is a “universal” certification to allow the HVAC technician to work on any type of equipment containing refrigerant. Your HVAC technician should be certified as “Level II Certified” at a minimum or, preferably, “Universal Certification” to work on your central air conditioner. Obtaining this certification information from your professional HVAC technician may be required in the event you are working with a realtor to sell your home. Costs for certification average $40 to $240.
With over 30 years in the Space Coast HVAC industry, the team at Kabran Air Conditioning & Heating knows just how complex and involved commercial heating and cooling systems can be. Our licensed and highly trained technicians are more than prepared to provide the expertise and knowledge that’s required for your business. As a Carrier Factory Authorized Dealer, our team of contractors is always up-to-date on training and more than qualified to handle your commercial heating and air conditioning repairs, installations, and maintenance. We provide a level of comfort and confidence in your AC and heating systems that goes unmatched. Contact the commercial HVAC experts of Cocoa Beach FL, Satellite Beach FL, Cape Canaveral FL, Rockledge FL, Melbourne FL, Merritt Island FL, Viera FL, Indian Harbour Beach FL today!
Before opening the electrical cover on the A/C unit, be sure to shut off all power to the compressor unit and the indoor furnace or air handler, and verify that it is off. Note that this may mean shutting off a circuit breaker that serves the furnace and air handler, and then, near the compressor, pulling out the disconnect block (or shutting off the 220-volt power) to the outdoor compressor.
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
It’s a rare occasion for a problem to arise with your heating or cooling equipment at a convenient time. In fact, we’re not even certain such a time exists! That’s why the team at HVAC & Plumbing Unlimited stands ready to provide complete emergency heating and cooling repairs. No matter the time of day or the day itself, we can be on the way and ready to provide prompt, cost-efficient services to our Alexandria clients.*
A dehumidifier is an air-conditioner-like device that controls the humidity of a room or building. It is often employed in basements which have a higher relative humidity because of their lower temperature (and propensity for damp floors and walls). In food retailing establishments, large open chiller cabinets are highly effective at dehumidifying the internal air. Conversely, a humidifier increases the humidity of a building.
Although HVAC is executed in individual buildings or other enclosed spaces (like NORAD's underground headquarters), the equipment involved is in some cases an extension of a larger district heating (DH) or district cooling (DC) network, or a combined DHC network. In such cases, the operating and maintenance aspects are simplified and metering becomes necessary to bill for the energy that is consumed, and in some cases energy that is returned to the larger system. For example, at a given time one building may be utilizing chilled water for air conditioning and the warm water it returns may be used in another building for heating, or for the overall heating-portion of the DHC network (likely with energy added to boost the temperature).[4][5][6]
Any concern with your cooling system, however minor, is worth checking out.  NATE-certified technicians can quickly identify the problem and prevent more extensive and costly damage.  Catching defects quickly is the key to cost-effective repairs.  Elevated operational noise such as grinding, screeching, or wheezing is more than aggravating.  Think of those sounds as warning bells.  They’re an indication of component failure.  Listen to what they’re telling you and call for professional assistance.  Worn or misaligned belts are easily repaired.  Strange smells from contaminants such as mold or mildew are best handled before allergens enter breathing air, diminish airflow, and block the coil.  Temperature swings, unstable humidity, or extended run times are all signs of bigger problems on the way.  Call Ferran Services at 407-422-3551 (Orlando) or 386-322-6168 (Volusia), and our licensed technicians will perform a complete system check, ensuring safe, efficient and reliable operation.

Home | About | Careers | Maintenance Plans | Services | Repairs & Maintenance | Residential Replacement | New Construction | Products | Furnaces | Air Conditioners | Heat Pumps | Ductless Systems | Thermostats | Air Cleaners | Humidifiers | Resources | Special Savings | Testimonials | Blog | Gallery | Contact | Site Map Charlotte Heating & Cooling | Dewitt Heating & Cooling | Dimondale Heating & Cooling | East Lansing Heating & Cooling | Eaton Rapids Heating & Cooling | Haslett Heating & Cooling | Holt Heating & Cooling | Lansing Heating & Cooling | Mason Heating & Cooling | Mulliken Heating & Cooling | Okemos Heating & Cooling | Portland Heating & Cooling | Webberville Heating & Cooling | Williamston Heating & Cooling
Dichlorodifluoromethane (R-12) was the most common blend used in automobiles in the U.S. until 1994, when most designs changed to R-134A due to the ozone-depleting potential of R-12. R-11 and R-12 are no longer manufactured in the U.S. for this type of application, so the only source for air-conditioning repair purposes is the cleaned and purified gas recovered from other air conditioner systems. Several non-ozone-depleting refrigerants have been developed as alternatives, including R-410A. It was first commercially used by Carrier Corp. under the brand name Puron.[citation needed]
If a heat exchanger cracks or contains holes, leaks can release carbon monoxide into your home. Carbon monoxide is nearly impossible for humans to detect on their own due to its characteristics of being colorless and odorless. Because of this, it is referred to as “The Silent Killer”. Some symptoms of carbon monoxide poisoning include headache, dizziness, fatigue, nausea and vomiting. It is extremely important to have a HVAC technician perform a furnace inspection annually to prevent problems such as carbon monoxide poisoning. UGI Heating, Cooling & Plumbing offers yearly maintenance packages and service agreements that include yearly maintenance and furnace inspections.
Your furnace's flame sensor is essentially a safety mechanism. As a thin metallic rod in front of the flame inside the unit, it's sole purpose is to confirm that your gas valves only open when a flame actually exists to burn that gas. When the flame sensor stop working, on the other hand, gas leaks can occur. To repair your furnace's flame sensor, expect to spend between $80 and $250. Even a full replacement of this part typically does not go above that range.

CIBSE publishes several guides to HVAC design relevant to the UK market, and also the Republic of Ireland, Australia, New Zealand and Hong Kong. These guides include various recommended design criteria and standards, some of which are cited within the UK building regulations, and therefore form a legislative requirement for major building services works. The main guides are:
Central, "all-air" air-conditioning systems (or package systems) with a combined outdoor condenser/evaporator unit are often installed in North American residences, offices, and public buildings, but are difficult to retrofit (install in a building that was not designed to receive it) because of the bulky air ducts required. (Minisplit ductless systems are used in these situations.) Outside of North America, packaged systems are only used in limited applications involving large indoor space such as stadiums, theatres or exhibition halls.
Reinstall the access panel and disconnect block. Turn on the circuit breaker and furnace switch. Then set the thermostat to a lower temperature and wait for the AC to start (see “Be Patient at Startup,” below). The compressor should run and the condenser fan should spin. If the compressor starts but the fan doesn’t, the fan motor is most likely shot. Shut off the power and remove the screws around the condenser cover. Lift the cover and remove the fan blade and motor (photo 7). Reinstall the blade and secure the cover. Then repower the unit and see if the fan starts. If it doesn’t, you’ve given it your best shot—it’s time to call a pro.
Shortly thereafter, the first private home to have air conditioning was built in Minneapolis in 1914, owned by Charles Gates.[11] Realizing that air conditioning would one day be a standard feature of private homes, particularly in regions with warmer climate, David St. Pierre DuBose (1898-1994) designed a network of ductwork and vents for his home Meadowmont, all disguised behind intricate and attractive Georgian-style open moldings.[when?] This building is believed to be one of the first private homes in the United States equipped for central air conditioning.[12]
We are so happy with the service and the unit installed. Carlos, the sales representative, was very attentive to our needs at the time. He knew exactly what we needed for our a/c concerns. Brandon Hayword, the a/c installer was amazing. I have never seen a technician so meticulous. Every detail was attended to. Poor guy worked from morning till 4:00 Am the next day. Never heard a complaint or wanted to go home and call it a night. Again, thank-you for the great service.
An alternative to packaged systems is the use of separate indoor and outdoor coils in split systems. Split systems are preferred and widely used worldwide except in North America. In North America, split systems are most often seen in residential applications, but they are gaining popularity in small commercial buildings. The split systems are a great choice for small buildings where ductwork is not feasible or where the space conditioning efficiency is of prime concern [21]. The benefits of ductless air conditioning systems include easy installation, no ductwork, greater zonal control, flexibility of control and quiet operation [22]. In space conditioning, the duct losses can account for 30% of energy consumption [23]. The use of minisplit can result in energy savings in space conditioning as there are no losses associated with ducting.
A mini-split system typically supplies air conditioned and heated air to a single or a few rooms of a building.[38] Multi-zone systems are a common application of ductless systems and allow up to 8 rooms (zones) to be conditioned from a single outdoor unit. Multi-zone systems typically offer a variety of indoor unit styles including wall-mounted, ceiling-mounted, ceiling recessed, and horizontal ducted. Mini-split systems typically produce 9,000 to 36,000 Btu (9,500–38,000 kJ) per hour of cooling. Multi-zone systems provide extended cooling and heating capacity up to 60,000 Btu's.

At BGE HOME, our customers trust our courteous and knowledgeable technicians to repair the most sophisticated heating and air conditioning system breakdowns. Every BGE HOME technician is licensed in their trade and adheres to a stringent in-house certification program that guarantees their knowledge, affirms their commitment to the customer, and ensures excellence in completing every heating and air conditioning repair with the highest level of quality.
We are open from 7am to 10pm every weekday and from 7am to 8pm on weekends. We book appointments in a 2 hour arrival window and call 30-45 mins before we arrive so you do not have to sit around waiting. It is often possible to schedule your appointment in the evening or morning hours to avoid conflicting with your work schedule. Are you looking for service today? Give us a call or click on one of the Schedule Service buttons found on the top and left sides of this page to contact us today.
Close all the windows in the house, turn off all the fans and exhaust fans, and shut off the furnace. Light some incense and walk slowly around the outer walls of the house. Anywhere you notice the smoke blowing away from something or being sucked toward something, there’s probably an air leak. Now that you’ve found it, seal it! Here’s how. Here are more ways to improve energy efficiency in your home.
To keep your furnace in good working order it’s important to have it regularly cleaned. The national average furnace cleaning cost ranges from $60 to $80, though prices can vary greatly based on where you live in the country and what your furnace maintenance includes. An HVAC company may have different rates for different levels of furnace maintenance. For example,one company may offer general furnace maintenance for $79 and advanced maintenance for $138. Another company may offer a 38-point maintenance check for $89 and a 64-point maintenance check for $178. According to Energy.gov, a standard furnace cleaning and maintenance visit can include:
Contending with South Florida’s temperature extremes is easy — if you have a heating and air conditioning contractor you can trust for prompt, dependable and affordable work. For over 40 years, our family-owned and operated company has helped home and business owners with their heating and cooling needs. From air conditioning repairs to maintaining heat pumps to installing a ductless system, you can rely on HI-VAC Air Conditioning Service. We are a full-service provider of HVAC services for Plantation, Miramar, Pembroke Pines, Weston, Coral Springs, Sunrise, FL, and the surrounding area.
Advantages of the ductless system include smaller size and flexibility for zoning or heating and cooling individual rooms. The inside wall space required is significantly reduced. Also, the compressor and heat exchanger can be located farther away from the inside space, rather than merely on the other side of the same unit as in a PTAC or window air conditioner. Flexible exterior hoses lead from the outside unit to the interior one(s); these are often enclosed with metal to look like common drainpipes from the roof. In addition, ductless systems offer higher efficiency, reaching above 30 SEER.[39]

Any concern with your cooling system, however minor, is worth checking out.  NATE-certified technicians can quickly identify the problem and prevent more extensive and costly damage.  Catching defects quickly is the key to cost-effective repairs.  Elevated operational noise such as grinding, screeching, or wheezing is more than aggravating.  Think of those sounds as warning bells.  They’re an indication of component failure.  Listen to what they’re telling you and call for professional assistance.  Worn or misaligned belts are easily repaired.  Strange smells from contaminants such as mold or mildew are best handled before allergens enter breathing air, diminish airflow, and block the coil.  Temperature swings, unstable humidity, or extended run times are all signs of bigger problems on the way.  Call Ferran Services at 407-422-3551 (Orlando) or 386-322-6168 (Volusia), and our licensed technicians will perform a complete system check, ensuring safe, efficient and reliable operation.
All consumer and property manager beware of this is not the old frymire anymore. they are under new ownership and with bunch rip-off tech! I am the property manager with a handyman and were unable to get the heat pump furnace relay replaced on time so I gave them another chance to do it base on good experience in previous. however, the tech used old school trick:telling me his truck dont have the relay and need to get the parts then will call me back. lone story short, we end up been charged for 290 for just a relay! and he even quoted us for a bad run capacitor for total 460!! we called them to provide a detail work invoice as usual and they never send to us so we end up to tell landlord that's how it is.. Huge mistake I ever made..don't trust them at all!!
Refrigeration air conditioning equipment usually reduces the absolute humidity of the air processed by the system. The relatively cold (below the dewpoint) evaporator coil condenses water vapor from the processed air, much like an ice-cold drink will condense water on the outside of a glass. Therefore, water vapor is removed from the cooled air and the relative humidity in the room is lowered. The water is usually sent to a drain or may simply drip onto the ground outdoors. The heat is ejected by the air conditioners condenser, which is located outside of the area being cooled.
×