The liquid refrigerant is returned to another heat exchanger where it is allowed to evaporate, hence the heat exchanger is often called an evaporating coil or evaporator. As the liquid refrigerant evaporates it absorbs energy (heat) from the inside air, returns to the compressor, and repeats the cycle. In the process, heat is absorbed from indoors and transferred outdoors, resulting in cooling of the building.
Contending with South Florida’s temperature extremes is easy — if you have a heating and air conditioning contractor you can trust for prompt, dependable and affordable work. For over 40 years, our family-owned and operated company has helped home and business owners with their heating and cooling needs. From air conditioning repairs to maintaining heat pumps to installing a ductless system, you can rely on HI-VAC Air Conditioning Service. We are a full-service provider of HVAC services for Plantation, Miramar, Pembroke Pines, Weston, Coral Springs, Sunrise, FL, and the surrounding area.
The heat-exchanger cools the air that is being forced through it by the furnace blower. As the warm air comes in contact with this cool surface the water in the air condenses. By pulling the water molecules from the air. According to the psychometric chart[42] as relative humidity decreases in order to feel cool you will have to lower the temperature even more. A common way to counteract this effect is by installing a whole-home humidifier.[43] Similarly, installing a high efficient system this need to turn the temperature down wont have such and influence on your energy costs.
If your furnace’s motor runs but the blower doesn’t move air, the belt that connects the two probably has broken. Replacing it is an easy fix. First, turn off all power to the unit and turn off the gas at the gas valve that serves the furnace. Remove the door on the front of the furnace cabinet to give you access to the blower (it might be on a slide-out drawer.) Check the number stamped on the belt and get an exact replacement from a home center or heating supply outlet.
It’s a rare occasion for a problem to arise with your heating or cooling equipment at a convenient time. In fact, we’re not even certain such a time exists! That’s why the team at HVAC & Plumbing Unlimited stands ready to provide complete emergency heating and cooling repairs. No matter the time of day or the day itself, we can be on the way and ready to provide prompt, cost-efficient services to our Alexandria clients.*
The heat-exchanger cools the air that is being forced through it by the furnace blower. As the warm air comes in contact with this cool surface the water in the air condenses. By pulling the water molecules from the air. According to the psychometric chart[42] as relative humidity decreases in order to feel cool you will have to lower the temperature even more. A common way to counteract this effect is by installing a whole-home humidifier.[43] Similarly, installing a high efficient system this need to turn the temperature down wont have such and influence on your energy costs.
If you hear clicking that is followed by a hum or buzz, you’re probably hearing the fan motor attempting to start without the boost it needs from the capacitor. You can almost always conclude that the capacitor has failed. Sometimes you can get the compressor fan spinning (clockwise) by pushing it with a thin stick or long screwdriver poked through the grille. But the chances are good that this might work for one cycle, but the capacitor will fail next time the AC goes on. It’s best to replace the capacitor.
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
Kabran Air Conditioning & Heating is the first choice for heating and air conditioning on the Florida Space Coast! In addition to providing exceptional HVAC service, repair and installation, we also offer great deals and savings for our customers across Cocoa Beach FL, Satellite Beach FL, Cape Canaveral FL, Rockledge FL, Melbourne FL, Merritt Island FL, Viera FL, Indian Harbour Beach FL. Join our Cool Club to enjoy exclusive, member-only offers. Visit our special offers page today to see what we’re currently offering, and contact Kabran Air Conditioning & Heating for affordable heating and AC service in Cocoa Beach.
The blower assembly is located between your main furnace and the cold air return. The blower is responsible for pulling air from your home and then sending it through the furnace and the heat exchanger. The air gets circulated throughout the home via the duct work. The furnace’s air filter is contained within the blower compartment. Regular-style filters should be replaced or cleaned each month.
When your furnace isn’t regularly serviced it can operate less efficiently. This increases your energy bills and also prevents your furnace from keeping your home as warm as you like. Keep your furnace properly maintained with regular service. The national average furnace service cost is between $60 and $80. Companies may offer tuneup specials that cover all the necessary testing, tightening, measuring and cleaning to keep your equipment running at top efficiency. If you have a newer system, furnace service costs may be covered by your warranty. Outside of warranty, a basic tuneup might start at $58 and a more advanced maintenance cleaning could be over $120. Here are some signs your furnace may need service:

Circulating refrigerant vapor enters the compressor, where its pressure and temperature are increased. The hot, compressed refrigerant vapor is now at a temperature and pressure at which it can be condensed and is routed through a condenser. Here it is cooled by air flowing across the condenser coils and condensed into a liquid. Thus, the circulating refrigerant removes heat from the system and the heat is carried away by the air. The removal of this heat can be greatly augmented by pouring water over the condenser coils, making it much cooler when it hits the expansion valve.

Designed to improve manufacturing process control in a printing plant, Carrier's invention controlled not only temperature but also humidity. Carrier used his knowledge of the heating of objects with steam and reversed the process. Instead of sending air through hot coils, he sent it through cold coils (filled with cold water). The air was cooled, and thereby the amount of moisture in the air could be controlled, which in turn made the humidity in the room controllable. The controlled temperature and humidity helped maintain consistent paper dimensions and ink alignment. Later, Carrier's technology was applied to increase productivity in the workplace, and The Carrier Air Conditioning Company of America was formed to meet rising demand. Over time, air conditioning came to be used to improve comfort in homes and automobiles as well. Residential sales expanded dramatically in the 1950s.[citation needed]

The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).

×