If you hear clicking that is followed by a hum or buzz, you’re probably hearing the fan motor attempting to start without the boost it needs from the capacitor. You can almost always conclude that the capacitor has failed. Sometimes you can get the compressor fan spinning (clockwise) by pushing it with a thin stick or long screwdriver poked through the grille. But the chances are good that this might work for one cycle, but the capacitor will fail next time the AC goes on. It’s best to replace the capacitor.

Handling the service needs of homeowners throughout Orlando, FL, Volusia, FL since 1910, we’ve built our business on a foundation of well-earned trust.  We uphold an A+ rating from the Better Business Bureau.  As a Carrier Factory Authorized Dealer, Ferran Services has been further distinguished with the Carrier President’s Award.  Trust that your best interest is our priority.  At Ferran Services, it’s not about the sale.  It’s all about your long-term satisfaction.


The liquid refrigerant is returned to another heat exchanger where it is allowed to evaporate, hence the heat exchanger is often called an evaporating coil or evaporator. As the liquid refrigerant evaporates it absorbs energy (heat) from the inside air, returns to the compressor, and repeats the cycle. In the process, heat is absorbed from indoors and transferred outdoors, resulting in cooling of the building.
The belt should slip right into place. If it seems to be too tight or difficult to set in place, it may be necessary to adjust the motor mount to provide more slack. Then you can re-tighten the tension once the belt is in place. Check the manufacturer’s specifications for proper tension—in most cases, the belt should deflect about an inch when you press down on it.
If your thermostat has a small lever that moves along a calibrated scale that indicates “longer” (not the heat temperature lever), you can try adjusting this—the heat anticipator. Just set it one calibration mark closer to the “longer” setting if the furnace goes off and on too frequently or one mark away if the furnace allows room temperature to rise too high or drop too low before going on or off. It may take several hours for the thermostat to stabilize at this setting, so wait a while and then adjust it again if necessary.
Our goal is to make you more comfortable in your home. When your furnace, central air conditioner, heat pump or boiler stops working and you need service, call the professionals at BGE HOME. Heating and cooling system breakdowns occur at the most inconvenient times, so rely on our certified, skilled technicians to make the repair quickly and correctly the first time.
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
Even with the best air conditioning repair service Phoenix can offer, an AC unit that has reached the end of its shelf life must be replaced. If you are ready to upgrade or replace that aging system, call us now for a free estimate, or check out our AC Unit Replacement section. In addition to offering our own Precision Line with the best warranty available in the industry, we also partner with industry leaders to offer the highest quality equipment at the best possible price, and we personally stand behind all of our new equipment installations.
When you change the temperature on your thermostat, or the temperature in your home drops, a signal lets the furnace's igniter know that it's time to turn on. Igniters exist in both hot water boilers and forced air furnaces, replacing pilot lights as the switch your unit needs to kick on. Naturally, this is a core part in making sure it works reliably. When it stops working, your unit will not longer know when to actually heat your home. Fortunately, furnace igniter repair doesn't tend to be a major budget problem, and costs less than $300 on average.
The selection of the working fluids (refrigerants) has a significant impact not only on the performance of the air conditioners but on the environment as well. Most refrigerants used for air conditioning contribute to global warming, and many also deplete the ozone layer.[60] CFCs, HCFCs, and HFCs are potent greenhouse gases when leaked to the atmosphere.

If a heat exchanger cracks or contains holes, leaks can release carbon monoxide into your home. Carbon monoxide is nearly impossible for humans to detect on their own due to its characteristics of being colorless and odorless. Because of this, it is referred to as “The Silent Killer”. Some symptoms of carbon monoxide poisoning include headache, dizziness, fatigue, nausea and vomiting. It is extremely important to have a HVAC technician perform a furnace inspection annually to prevent problems such as carbon monoxide poisoning. UGI Heating, Cooling & Plumbing offers yearly maintenance packages and service agreements that include yearly maintenance and furnace inspections.


Multiple inventions within this time frame preceded the beginnings of first comfort air conditioning system, which was designed in 1902 by Alfred Wolff (Cooper, 2003) for the New York Stock Exchange, while Willis Carrier equipped the Sacketts-Wilhems Printing Company with the process AC unit the same year. Coyne College was the first school to offer HVAC training in 1899.[12]
In the most general sense, air conditioning can refer to any form of technology that modifies the condition of air (heating, (de-) humidification, cooling, cleaning, ventilation, or air movement). In common usage, though, "air conditioning" refers to systems which cool air. In construction, a complete system of heating, ventilation, and air conditioning is referred to as HVAC.[3]
Our goal is to make you more comfortable in your home. When your furnace, central air conditioner, heat pump or boiler stops working and you need service, call the professionals at BGE HOME. Heating and cooling system breakdowns occur at the most inconvenient times, so rely on our certified, skilled technicians to make the repair quickly and correctly the first time.
As a Carrier Factory Authorized Dealer, we are qualified in the most widely recognized and innovative selection of heating, cooling, and air quality options to satisfy any demand. From new installation and retrofit projects, to seasonal maintenance and repair, Modern Air Solutions optimizes the performance of equipment, targeting energy efficiency, reliability, and longevity.

Vacuum the fins of your AC unit clean with a soft-bristle brush. Note: they’re fragile and can easily be bent or crushed. On many units you’ll have to unscrew and lift off a metal box to get at them. Check your owner’s manual for directions and lift off the box carefully to avoid bumping the fins. Follow these other steps to safely clean your home air conditioner for better efficiency.

The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
A programmable thermostat is a must-have in today’s state of AC technology. Programmable thermostats allow you to set temperatures for various times throughout the day and automatically lower the temperature when you most need it to help you save money and manage your cooling without constantly hovering over the dial. In this article, we’ll walk you through installing a programmable thermostat in your home.
We happily offer all of our services in St Marys county. We view our neighbors in St. Mary’s county as important and valuable as our friends in Calvert. If you live in St Marys and you’re not sure if we can help you with your specific problem, please don’t hesitate to contact us and find out! We value all inquiries and our eager to help and assist our neighbors throughout all of Southern Maryland.
Next check and clean the furnace’s flame sensor. The video below shows you how—note that this guy fixes it in about 5 minutes. We would probably use a little bit of emory paper, but he cleans the sensor with a 5-dollar bill. Another video further down the page under the discussion of “If your furnace keeps shutting off after about 5 minutes” shows the same project with a different brand of furnace.
Repairs—If something appears to be not working right with your heating and cooling, a professional will examine the whole health of your system. It’s easy to hop on the internet and research information to find our own conclusions, but there could be an additional component or reason why your system isn’t working properly that isn’t clear or recognizable. Consider our own health concerns—you might check out your symptoms online to try and draw your conclusions, but it’s always best to make an appointment with a doctor to receive an expert opinion.
In the most general sense, air conditioning can refer to any form of technology that modifies the condition of air (heating, (de-) humidification, cooling, cleaning, ventilation, or air movement). In common usage, though, "air conditioning" refers to systems which cool air. In construction, a complete system of heating, ventilation, and air conditioning is referred to as HVAC.[3]
The selection of indoor units has one restriction: their total power should not exceed the capacity of the outdoor unit. In practice, however, it is very common to see a multi-split system with a total capacity of indoor units greater than the outdoor capacity by at least 20%. However, it is wrong to expect better performance when all indoor units are turned on at the same time, since the total capacity of the whole system is limited by the capacity of the outdoor unit. Simply put, the outdoor unit will distribute all its power to all operating indoor units in such a way that some of the rooms may not have a very comfortable temperature level. However, the calculation of the total power is not simple, since it takes into account not only the nominal power of the units, but also the cooling capacity, heating, dehumidification, humidification, venting, etc.
If your furnace’s motor runs but the blower doesn’t move air, the belt that connects the two probably has broken. Replacing it is an easy fix. First, turn off all power to the unit and turn off the gas at the gas valve that serves the furnace. Remove the door on the front of the furnace cabinet to give you access to the blower (it might be on a slide-out drawer.) Check the number stamped on the belt and get an exact replacement from a home center or heating supply outlet.
Refrigeration air conditioning equipment usually reduces the absolute humidity of the air processed by the system. The relatively cold (below the dewpoint) evaporator coil condenses water vapor from the processed air, much like an ice-cold drink will condense water on the outside of a glass. Therefore, water vapor is removed from the cooled air and the relative humidity in the room is lowered. The water is usually sent to a drain or may simply drip onto the ground outdoors. The heat is ejected by the air conditioners condenser, which is located outside of the area being cooled.
×