Air flow meter Aquastat BACnet Blower door Building automation Carbon dioxide sensor Clean Air Delivery Rate (CADR) Gas sensor Home energy monitor Humidistat HVAC control system Intelligent buildings LonWorks Minimum efficiency reporting value (MERV) OpenTherm Programmable communicating thermostat Programmable thermostat Psychrometrics Room temperature Smart thermostat Thermostat Thermostatic radiator valve

Heating, ventilation, and air conditioning (HVAC[1]) is the technology of indoor and vehicular environmental comfort. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation, as HVAC&R or HVACR or "ventilation" is dropped, as in HACR (as in the designation of HACR-rated circuit breakers).


To earn distinction as a Carrier Factory Authorized Dealer, Kabran Air Conditioning & Heating performs to exacting standards of customer dedication, business practices, and technical know-how.  Our technicians continue intensive factory training to remain current with increasingly sophisticated products and technology.  Our sales team attends Carrier University, ensuring complete product understanding and knowledgeable recommendations that perfectly suit your needs.  We maintain proper licensing, insurance and liability coverage, and fulfill warranty obligations in a timely manner.  By becoming experts in the state-of-the-art heating and cooling systems we install, accurate sizing, precision implementation, and long-term value is standard operating procedure at Kabran Air Conditioning & Heating.
It can be difficult to find the right company to do Aurora furnace repair and Aurora furnace replacement. When looking for the right help choose an Aurora furnace replacement and repair company that comes recommended and has a strong reputation. As a licensed furnace replacement company in Denver, Brothers Plumbing Heating and Electric has been working on the repair and replacement of furnaces for many years. Furthermore, we have a long list of happy customers that recommend us to all their friends and family.
American design standards are legislated in the Uniform Mechanical Code or International Mechanical Code. In certain states, counties, or cities, either of these codes may be adopted and amended via various legislative processes. These codes are updated and published by the International Association of Plumbing and Mechanical Officials (IAPMO) or the International Code Council (ICC) respectively, on a 3-year code development cycle. Typically, local building permit departments are charged with enforcement of these standards on private and certain public properties.
The Environmental Protection Agency (EPA) requires that all technicians who open a system containing a controlled refrigerant be certified to do so. There are four levels of certification, one of which is a “universal” certification to allow the HVAC technician to work on any type of equipment containing refrigerant. Your HVAC technician should be certified as “Level II Certified” at a minimum or, preferably, “Universal Certification” to work on your central air conditioner. Obtaining this certification information from your professional HVAC technician may be required in the event you are working with a realtor to sell your home. Costs for certification average $40 to $240.

Air flow meter Aquastat BACnet Blower door Building automation Carbon dioxide sensor Clean Air Delivery Rate (CADR) Gas sensor Home energy monitor Humidistat HVAC control system Intelligent buildings LonWorks Minimum efficiency reporting value (MERV) OpenTherm Programmable communicating thermostat Programmable thermostat Psychrometrics Room temperature Smart thermostat Thermostat Thermostatic radiator valve


Modern air conditioning systems are not designed to draw air into the room from the outside, they only recirculate the increasingly cool air on the inside. Because this inside air always has some amount of moisture suspended in it, the cooling portion of the process always causes ambient warm water vapor to condense on the cooling coils and to drip from them down onto a catch tray at the bottom of the unit from which it must then be routed outside, usually through a drain hole. As this moisture has no dissolved minerals in it, it will not cause mineral buildup on the coils. This will happen even if the ambient humidity level is low. If ice begins to form on the evaporative fins, it will reduce circulation efficiency and cause the development of more ice, etc. A clean and strong circulatory fan can help prevent this, as will raising the target cool temperature of the unit's thermostat to a point that the compressor is allowed to turn off occasionally. A failing thermistor may also cause this problem. Refrigerators without a defrost cycle may have this same issue. Dust can also cause the fins to begin blocking air flow with the same undesirable result: ice.


Gas furnaces and heaters have control shutoffs to prevent gas leaks, but they are not fail-safe. If you smell gas in your house, do not turn any lights on or off, and do not try to shut off the gas leading to the furnace. Get out of the house, leaving the door open, and immediately call the gas company or the fire department to report a leak. Do not re-enter your home.
It’s a rare occasion for a problem to arise with your heating or cooling equipment at a convenient time. In fact, we’re not even certain such a time exists! That’s why the team at HVAC & Plumbing Unlimited stands ready to provide complete emergency heating and cooling repairs. No matter the time of day or the day itself, we can be on the way and ready to provide prompt, cost-efficient services to our Alexandria clients.*

This type of furnace is fueled by liquid propane gas, which is burned to push hot air through your home. A pilot light ignites the burners within a combustion chamber, which push heat into the heat exchanger and eventually through your entire home. Repairing this type of furnace can be more expensive than its electric alternative. For example here are some common propane gas repairs and their costs:


Within the construction sector, it is the job of the building services engineer to design and oversee the installation and maintenance of the essential services such as gas, electricity, water, heating and lighting, as well as many others. These all help to make buildings comfortable and healthy places to live and work in. Building Services is part of a sector that has over 51,000 businesses and employs represents 2%-3% of the GDP.

Your HVAC professional can also help you verify that your system is properly matched by providing you with an AHRI Certificate of Certified Product Performance upon request. The certificate verifies that the outdoor unit (condenser) and the indoor unit (evaporator) combination has been certified as a matched system by the Air Conditioning, Heating and Refrigeration Institute (AHRI). For higher efficiency systems, this certification may help you obtain a rebate from your utility or local municipality if you have to replace your unit in whole or in part. Not all areas offer a rebate, but your technician will likely be able to provide information about the certification process. Fees for performing this certification vary, but generally are relatively inexpensive.


Evaporative coolers tend to feel as if they are not working during times of high humidity, when there is not much dry air with which the coolers can work to make the air as cool as possible for dwelling occupants. Unlike other types of air conditioners, evaporative coolers rely on the outside air to be channeled through cooler pads that cool the air before it reaches the inside of a house through its air duct system; this cooled outside air must be allowed to push the warmer air within the house out through an exhaust opening such as an open door or window.[28] These coolers cost less and are mechanically simple to understand and maintain.
Whole-house fans have helped cool homes for a century. The basic design is simple: An attic-mounted fan pushes hot air out through attic vents and draws cooler, outside air in through open doors and windows. This rapid air exchange—large fans can purge a house of hot air in two to three minutes—not only removes built-up heat but also creates a pleasant breeze.
Gas furnaces and heaters have control shutoffs to prevent gas leaks, but they are not fail-safe. If you smell gas in your house, do not turn any lights on or off, and do not try to shut off the gas leading to the furnace. Get out of the house, leaving the door open, and immediately call the gas company or the fire department to report a leak. Do not re-enter your home.

Designed to improve manufacturing process control in a printing plant, Carrier's invention controlled not only temperature but also humidity. Carrier used his knowledge of the heating of objects with steam and reversed the process. Instead of sending air through hot coils, he sent it through cold coils (filled with cold water). The air was cooled, and thereby the amount of moisture in the air could be controlled, which in turn made the humidity in the room controllable. The controlled temperature and humidity helped maintain consistent paper dimensions and ink alignment. Later, Carrier's technology was applied to increase productivity in the workplace, and The Carrier Air Conditioning Company of America was formed to meet rising demand. Over time, air conditioning came to be used to improve comfort in homes and automobiles as well. Residential sales expanded dramatically in the 1950s.[citation needed]
Furnaces and thermostats are not mix-and-match appliances. Using the wrong type of thermostat with a furnace will cause operating problems and can be dangerous. Although thermostats look similar, they are designed very differently. There are numerous types of heating systems and thermostat systems and they need to be coordinated for safe and proper operation. There are three types of thermostat systems used today: millivoltage, low voltage, and line voltage.​
The contactor (relay) and start/run capacitor(s) (see illustration below) fail most often and are inexpensive. So it’s a safe bet to buy and install those parts right away, especially if your air conditioning service unit is older than five years. The condenser fan motor can also fail, but it runs about $150 — hold off buying that unless you’re sure that’s the culprit.

The selection of the working fluids (refrigerants) has a significant impact not only on the performance of the air conditioners but on the environment as well. Most refrigerants used for air conditioning contribute to global warming, and many also deplete the ozone layer.[60] CFCs, HCFCs, and HFCs are potent greenhouse gases when leaked to the atmosphere.
At times, malfunctions strike without warning.  These problems rarely stick to regular business hours.  When your comfort, safety, and well-being is at stake, don’t wait for Monday morning.  The service team from Ferran Services is available 24/7 to provide the prompt and dependable assistance you require.  Fully-stocked service trucks and extensively trained technicians allow us to handle the majority of repair requirements in a single visit.  We work on all makes and models, and our technicians do not rely on commission.  We never take advantage of your desperate situation, never sell you a product or service you don’t need, and always keep you informed.  By relying on Factory Authorized Parts, we restore system efficiency, sound levels, and longevity.

We’ve proudly represented the very best Atlanta has to offer in superior service for 50 years. In that time, we’ve accumulated all it takes and more to bring you the best emergency heating and air conditioning repair services possible. Story after story, we deliver smiles! If you’re looking for a reliable company that provides 24-hour AC repair, don’t hesitate to contact us right away—770-913-6412!
Demand controlled kitchen ventilation (DCKV) is a building controls approach of slowing down kitchen exhaust fans and subsequent supply air in response to the actual cooking loads in a commercial kitchen. Traditional commercial kitchen ventilation systems operate at 100% fan speed independent of the volume of cooking activity and DCKV technology changes that to provide significant fan energy and conditioned air savings. By deploying smart sensing technology, both the exhaust and supply fans can be controlled to capitalize on the Law of Affinity for motor energy savings, reduce makeup air heating and cooling energy, increasing safety and reducing ambient kitchen noise levels.[30]
We had an exceptional experience with Gator Air, in particular Carlos. He presented us with quotes for different types of AC units, told us facts about said units and left us to make our decision. No high pressure sales. The installers were professional and cleaned up when they were through. A nice surprise was the 1 year free maintenance of the unit. We belonged to the Gator Club so to not have to pay it for the next year was an added bonus. Thank you GatorAir for making the experience an enjoyable one.
HVAC repair technicians are properly qualified to take care of anything that relates to installing, maintaining or repairing your heating, air conditioning and refrigeration systems. Our professionals have gone through rigorous training and certification and all our technicians and equipment installers are NATE-certified, which involves demanding testing and indicates a solid understanding of the industry.
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
×