Refrigeration air conditioning equipment usually reduces the absolute humidity of the air processed by the system. The relatively cold (below the dewpoint) evaporator coil condenses water vapor from the processed air, much like an ice-cold drink will condense water on the outside of a glass. Therefore, water vapor is removed from the cooled air and the relative humidity in the room is lowered. The water is usually sent to a drain or may simply drip onto the ground outdoors. The heat is ejected by the air conditioners condenser, which is located outside of the area being cooled.
Within the construction sector, it is the job of the building services engineer to design and oversee the installation and maintenance of the essential services such as gas, electricity, water, heating and lighting, as well as many others. These all help to make buildings comfortable and healthy places to live and work in. Building Services is part of a sector that has over 51,000 businesses and employs represents 2%-3% of the GDP.
The condensed, pressurized, and still usually somewhat hot liquid refrigerant is next routed through an expansion valve (often nothing more than a pinhole in the system's copper tubing) where it undergoes an abrupt reduction in pressure. That pressure reduction results in flash evaporation of a part of the liquid refrigerant, greatly lowering its temperature. The cold refrigerant is then routed through the evaporator. A fan blows the interior warm air (which is to be cooled) across the evaporator, causing the liquid part of the cold refrigerant mixture to evaporate as well, further lowering the temperature. The warm air is therefore cooled and is pumped by an exhaust fan/ blower into the room. To complete the refrigeration cycle, the refrigerant vapor is routed back into the compressor. In order for the process to have any efficiency, the cooling/evaporative portion of the system must be separated by some kind of physical barrier from the heating/condensing portion, and each portion must have its own fan to circulate its own "kind" of air (either the hot air or the cool air).
Installation—Having your HVAC systems installed by a professional is extremely important to prevent any future problems or needless repairs. Our professionals at Service Experts Heating & Air Conditioning can also help you choose what size equipment is appropriate for your house. Selecting a system that is too large or small can impact efficiency and add to your energy bills.

Air conditioning and refrigeration are provided through the removal of heat. Heat can be removed through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are referred to as refrigerants. A refrigerant is employed either in a heat pump system in which a compressor is used to drive thermodynamic refrigeration cycle, or in a free cooling system which uses pumps to circulate a cool refrigerant (typically water or a glycol mix).

If your furnace is more than 15 years old or broken beyond repair, furnace replacement is necessary. Old furnaces are very inefficient which means that you could be spending more on your gas or electric bill than you need to. Old furnaces can also be very hazardous to your health and home. Furnaces are basically controlled fires, and when the control systems on your furnace are out of date or malfunctioning, the safety of your home is in jeopardy. If you have an old or malfunctioning furnace, or if you want a safety check on your current system, then give our furnace replacement company a call today!


2) Keep your coils clean. The AC coils and fins on the outside of your unit need to be kept clean and clear of obstructions. Leaves and other debris sometimes accumulate around your unit. If obstructions are present, your unit must work harder to function than it should. You can clean your unit with a regular garden hose and a broom. Do not use a pressure washer, as the strong spray could cause harm to your system. A little bit of housekeeping in this regard goes far toward keeping your air conditioner working optimally. 
In 1995, Germany made CFC refrigerators illegal.[22] DuPont and other companies blocked the refrigerant in the U.S. with the U.S. EPA, disparaging the approach as "that German technology".[21][23] Nevertheless, in 2004, Greenpeace worked with multinational corporations like Coca-Cola and Unilever, and later Pepsico and others, to create a corporate coalition called Refrigerants Naturally!.[22][24] Then, four years later, Ben & Jerry's of Unilever and General Electric began to take steps to support production and use in the U.S.[25] In 2011 the EPA decided in favor of the ozone- and climate-safe refrigerant for U.S. manufacture.[17][26][27]

When your gas furnace isn’t blowing hot air, the issue could be due to a faulty pilot light or broken ignitor. Remove the furnace cover panel and visually inspect whether you can see a flame from the pilot light. A natural gas furnace will be blue and yellow in color, and a propane furnace should have a bluish green flame with a yellow tip. If you can see a flame and it appears normal, the issue could be related to the furnace blower motor or other complex furnace parts. If the flame appears low or non-existent, it’s best to contact an experienced furnace repair company. Remember to never touch any open wires; contact a professional.
Whether it’s a sticky day in July and you need an AC repair, or your employees are having trouble breathing because of stagnant indoor air, you can rely on HI-VAC Air Conditioning Service to quickly resolve your problem. We are the go-to source for air conditioning services in Plantation, Miramar, Pembroke Pines, Weston, Coral Springs, Sunrise, FL and the surrounding area. Give us a call today to learn how we can improve your indoor comfort.
Whether it’s a sticky day in July and you need an AC repair, or your employees are having trouble breathing because of stagnant indoor air, you can rely on HI-VAC Air Conditioning Service to quickly resolve your problem. We are the go-to source for air conditioning services in Plantation, Miramar, Pembroke Pines, Weston, Coral Springs, Sunrise, FL and the surrounding area. Give us a call today to learn how we can improve your indoor comfort.
Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
×