Precision’s technicians are all NATE certified. This is the highest certification in the air conditioning industry. With that, we can take pride in saying that we provide the best AC repair Phoenix residents can get. Our technicians are thoroughly screened and tested before they begin work on your home. Our AC technicians provide top-notch Phoenix air conditioning repair, and proof of that is their ability to repair most every brand of HVAC equipment. These brands include Trane, Bryant, Ruud, Goodman, Amana, Precision, Armstrong, Carrier, Coleman, Honeywell, Janitrol, Lennox, Payne, Rheem, York, Goettl, American Standard along with many more.
Given the broad price ranges above, it's easy to recognize that the cost of your furnace repair varies drastically based on which parts need attention. As a result, it makes sense to gain a better understanding of the parts that heat your home, and how much they cost to repair. Repairing or replacing your furnace’s blower motor can cost you anywhere between $150 and $450, depending on the extent of the damage. Heat exchanger repair costs can vary greatly, from as little as $100 for a simple fix to as much as $1,200 for a full replacement. Repairing a furnace igniter will only cost you $300 at most, while flame sensor repairs generally fall between $80 to $250. The average cost to repair your Thermostat will range from $108 to $282.
During our formative years, we were a member of the Refrigeration Service Engineers Society (RSES). Since then, we have been a long-standing member of the Better Business Bureau (BBB) and are closely aligned with Trane. We are a Certified Trane Dealer and Trane Comfort Specialist—the highest level of certification awarded by Trane. In fact, we have earned the Trane Distinguished Dealer Award 11 times!
When it comes to HVAC service in Cocoa Beach and throughout the Space Coast region, the team at Kabran Air Conditioning & Heating always has your best interests in mind. Not only do we provide the most innovative heating and air conditioning products from Carrier, we also offer flexible financing options, with approved credit, through Wells Fargo. Now you can enjoy your new furnace or AC system with additional financial benefits such as convenient monthly payments, competitive interest rates, and flexible payment options. To learn more about our financing options or to apply today, contact the premier HVAC company of Cocoa Beach today!
AC air handler squealing or grinding noises. Though most air handlers have direct-drive motors, some older units may be belt-driven. Squealing sounds from a belt-drive air handler generally occur when the belt that connects the motor to the blower slips. In most cases, the belt is improperly aligned or worn and needs replacement. Follow the instructions above under Air Conditioner Not Blowing Air and refer to your owner’s manual.
Most central air conditioners have two basic parts: an outdoor unit (compressor/condenser) that sits next to your home and an indoor unit (evaporator) that’s located in a central duct near your furnace. If you have a heat pump instead of a furnace, the indoor unit will be in the air handler. Use the same maintenance steps we show here. If your furnace looks different from the one shown or you have a heat pump, use the owner’s manual to find your way around it. The basic parts will be the same. Check out our step-by-step guide for deep-cleaning your home air conditioner.
An air conditioning system, or a standalone air conditioner, provides cooling and humidity control for all or part of a building. Air conditioned buildings often have sealed windows, because open windows would work against the system intended to maintain constant indoor air conditions. Outside, fresh air is generally drawn into the system by a vent into the indoor heat exchanger section, creating positive air pressure. The percentage of return air made up of fresh air can usually be manipulated by adjusting the opening of this vent. Typical fresh air intake is about 10%.
In the United States, HVAC engineers generally are members of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), EPA Universal CFC certified (for installation and service of CFC HVAC devices), or locally engineer certified such as a Special to Chief Boilers License issued by the state or, in some jurisdictions, the city. ASHRAE is an international technical society for all individuals and organizations interested in HVAC. The Society, organized into regions, chapters, and student branches, allows exchange of HVAC knowledge and experiences for the benefit of the field's practitioners and the public. ASHRAE provides many opportunities to participate in the development of new knowledge via, for example, research and its many technical committees. These committees typically meet twice per year at the ASHRAE Annual and Winter Meetings. A popular product show, the AHR Expo, is held in conjunction with each winter meeting. The Society has approximately 50,000 members and has headquarters in Atlanta, Georgia.
1) Change your filter. The simplest and most effective way to keep your AC running smoothly is changing your filter once a month. By regularly changing your filter, you reduce a lot of the burden on your system. A dirty or clogged filter makes your air conditioner work much harder than does a clean filter. Changing your filters regularly is easy on your budget and easy on your system as well. It will lower your utility bill and extend the life of your AC.
The heat-exchanger cools the air that is being forced through it by the furnace blower. As the warm air comes in contact with this cool surface the water in the air condenses. By pulling the water molecules from the air. According to the psychometric chart[42] as relative humidity decreases in order to feel cool you will have to lower the temperature even more. A common way to counteract this effect is by installing a whole-home humidifier.[43] Similarly, installing a high efficient system this need to turn the temperature down wont have such and influence on your energy costs.
In addition to the information below, see these two articles for the general care and maintenance of your air conditioner: Preparing Your Air Conditioner for Summer and How to Replace Furnace & AC Filters. Most noteworthy, you should replace the filters at least twice a year, before the heating and cooling seasons. For information on furnace problems, please see Furnace Not Working.
In 1902, the first modern electrical air conditioning unit was invented by Willis Carrier in Buffalo, New York.[citation needed] After graduating from Cornell University, Carrier found a job at the Buffalo Forge Company. There, he began experimenting with air conditioning as a way to solve an application problem for the Sackett-Wilhelms Lithographing and Publishing Company in Brooklyn, New York. The first air conditioner, designed and built in Buffalo by Carrier, began working on 17 July 1902.[citation needed]
Ground source, or geothermal, heat pumps are similar to ordinary heat pumps, but instead of transferring heat to or from outside air, they rely on the stable, even temperature of the earth to provide heating and air conditioning. Many regions experience seasonal temperature extremes, which would require large-capacity heating and cooling equipment to heat or cool buildings. For example, a conventional heat pump system used to heat a building in Montana's −70 °F (−57 °C) low temperature or cool a building in the highest temperature ever recorded in the US—134 °F (57 °C) in Death Valley, California, in 1913 would require a large amount of energy due to the extreme difference between inside and outside air temperatures. A few feet below the earth's surface, however, the ground remains at a relatively constant temperature. Utilizing this large source of relatively moderate temperature earth, a heating or cooling system's capacity can often be significantly reduced. Although ground temperatures vary according to latitude, at 6 feet (1.8 m) underground, temperatures generally only range from 45 to 75 °F (7 to 24 °C).

If your air conditioning is blowing warm air—or not working at all—it's time to call in the experts. After all, we're not just talking about an uncomfortable afternoon on a hot day: we're talking about your happiness at home, and a problem that may cause extensive damage to your system if not addressed quickly. That's why it's smart to catch problems early before they become expensive to address.

The performance of vapor compression refrigeration cycles[27] is limited by thermodynamics. These air conditioning and heat pump devices move heat rather than convert it from one form to another, so thermal efficiencies do not appropriately describe the performance of these devices. The Coefficient-of-Performance (COP) measures performance, but this dimensionless measure has not been adopted. Instead, the Energy Efficiency Ratio (EER) has traditionally been used to characterize the performance of many HVAC systems. EER is the Energy Efficiency Ratio based on a 35 °C (95 °F) outdoor temperature. To more accurately describe the performance of air conditioning equipment over a typical cooling season a modified version of the EER, the Seasonal Energy Efficiency Ratio (SEER), or in Europe the ESEER, is used. SEER ratings are based on seasonal temperature averages instead of a constant 35 °C (95 °F) outdoor temperature. The current industry minimum SEER rating is 14 SEER.[28]

You shouldn’t have to spend any more time in a state of discomfort than is necessary. If you feel like your home’s HVAC isn’t operating as smoothly and efficiently as it should, or you can tell you should be getting more out of your home’s air conditioning system, call Gainesville Mechanical, Inc. for air conditioning unit repair, and we can send someone to your door anytime day or night.
Our goal is to make you more comfortable in your home. When your furnace, central air conditioner, heat pump or boiler stops working and you need service, call the professionals at BGE HOME. Heating and cooling system breakdowns occur at the most inconvenient times, so rely on our certified, skilled technicians to make the repair quickly and correctly the first time.

Air conditioner equipment power in the U.S. is often described in terms of "tons of refrigeration", with each approximately equal to the cooling power of one short ton (2000 pounds or 907 kilograms) of ice melting in a 24-hour period. The value is defined as 12,000 BTU per hour, or 3517 watts.[32] Residential central air systems are usually from 1 to 5 tons (3.5 to 18 kW) in capacity.
If the condenser coils are clogged, the compressor can overheat and shut down. You’ll experience intermittent periods of minimal cooling, followed by no cooling. Even if you’re “sure” the condenser coils are clean, clean them again. Turn off the power. Flip the air conditioning service and furnace circuit breakers in your main electrical panel to the “Off” position. Next, turn off the power switch right at the furnace or air handler. Then yank the disconnect block (Photo 1) and clean the condenser coils (Photo 2). If the air conditioning service still doesn’t work properly after you’ve cleaned the condenser coils, installed a new filter and opened all the supply vents, proceed with the following repairs.
Service Experts Heating and Air Conditioning was founded on the basis of providing customers with the best heating and cooling practices in the industry. Since its inception, Service Experts has been dedicated to community, providing the top of the line HVAC products and services in your area. If you want more information about your local HVAC leaders, call us at 866-397-3787 or set up an appointment with us online.
In the United States, HVAC engineers generally are members of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), EPA Universal CFC certified (for installation and service of CFC HVAC devices), or locally engineer certified such as a Special to Chief Boilers License issued by the state or, in some jurisdictions, the city. ASHRAE is an international technical society for all individuals and organizations interested in HVAC. The Society, organized into regions, chapters, and student branches, allows exchange of HVAC knowledge and experiences for the benefit of the field's practitioners and the public. ASHRAE provides many opportunities to participate in the development of new knowledge via, for example, research and its many technical committees. These committees typically meet twice per year at the ASHRAE Annual and Winter Meetings. A popular product show, the AHR Expo, is held in conjunction with each winter meeting. The Society has approximately 50,000 members and has headquarters in Atlanta, Georgia.
In the case of heated water or steam, piping is used to transport the heat to the rooms. Most modern hot water boiler heating systems have a circulator, which is a pump, to move hot water through the distribution system (as opposed to older gravity-fed systems). The heat can be transferred to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be mounted on walls or installed within the floor to produce floor heat.
Our technicians are factory trained and have mastered all aspects of HVAC service. They also undergo constant training so that they will always be at the top of their game. We believe that staying informed of advances in air conditioning technology is one of the best ways we can guarantee satisfaction for our customers, whether we are handling an air conditioning repair or installing a new heat pump. We are licensed, bonded and insured.
Because an air conditioner moves heat between the indoor coil and the outdoor coil, both must be kept clean. This means that, in addition to replacing the air filter at the evaporator coil, it is also necessary to regularly clean the condenser coil. Failure to keep the condenser clean will eventually result in harm to the compressor, because the condenser coil is responsible for discharging both the indoor heat (as picked up by the evaporator) and the heat generated by the electric motor driving the compressor.
An annual inspection of your unit can ensure that the various potential problems mentioned above are detected early, and before they require complete replacement. During this inspection, for instance, a professional might find small cracks in your heat exchanger or a faulty seal in your blower motor. Some manufacturer's warranties even require these annual inspections to maintain validity. Typically, your furnace inspection will cost between $80 and $150 depending on the area in which you live and the professional you work with.
Air conditioning and refrigeration are provided through the removal of heat. Heat can be removed through radiation, convection, or conduction. Refrigeration conduction media such as water, air, ice, and chemicals are referred to as refrigerants. A refrigerant is employed either in a heat pump system in which a compressor is used to drive thermodynamic refrigeration cycle, or in a free cooling system which uses pumps to circulate a cool refrigerant (typically water or a glycol mix).
The first air conditioners and refrigerators employed toxic or flammable gases, such as ammonia, methyl chloride, or propane, that could result in fatal accidents when they leaked. Thomas Midgley, Jr. created the first non-flammable, non-toxic chlorofluorocarbon gas, Freon, in 1928. The name is a trademark name owned by DuPont for any chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or hydrofluorocarbon (HFC) refrigerant. The refrigerant names include a number indicating the molecular composition (e.g., R-11, R-12, R-22, R-134A). The blend most used in direct-expansion home and building comfort cooling is an HCFC known as chlorodifluoromethane (R-22).
An alternative to packaged systems is the use of separate indoor and outdoor coils in split systems. Split systems are preferred and widely used worldwide except in North America. In North America, split systems are most often seen in residential applications, but they are gaining popularity in small commercial buildings. The split systems are a great choice for small buildings where ductwork is not feasible or where the space conditioning efficiency is of prime concern [21]. The benefits of ductless air conditioning systems include easy installation, no ductwork, greater zonal control, flexibility of control and quiet operation [22]. In space conditioning, the duct losses can account for 30% of energy consumption [23]. The use of minisplit can result in energy savings in space conditioning as there are no losses associated with ducting.

As a Carrier Factory Authorized Dealer, we are qualified in the most widely recognized and innovative selection of heating, cooling, and air quality options to satisfy any demand. From new installation and retrofit projects, to seasonal maintenance and repair, Modern Air Solutions optimizes the performance of equipment, targeting energy efficiency, reliability, and longevity.
At Genz-Ryan, we are here for you 24 hours a day, 7 days a week so you can count on us for all your heating repair work in the Minneapolis area. Our furnace repair technicians are well-trained and experienced. They’re ready to take care of any heating issue that you may have. We are a Lennox Premier Furnace Dealer and provide expert furnace repair service for most of the Minneapolis/St. Paul area. For over 60 years we have been getting the job done right the first time.
Even with the best air conditioning repair service Phoenix can offer, an AC unit that has reached the end of its shelf life must be replaced. If you are ready to upgrade or replace that aging system, call us now for a free estimate, or check out our AC Unit Replacement section. In addition to offering our own Precision Line with the best warranty available in the industry, we also partner with industry leaders to offer the highest quality equipment at the best possible price, and we personally stand behind all of our new equipment installations.

If your thermostat has a small lever that moves along a calibrated scale that indicates “longer” (not the heat temperature lever), you can try adjusting this—the heat anticipator. Just set it one calibration mark closer to the “longer” setting if the furnace goes off and on too frequently or one mark away if the furnace allows room temperature to rise too high or drop too low before going on or off. It may take several hours for the thermostat to stabilize at this setting, so wait a while and then adjust it again if necessary.
Our fully trained and certified heating technicians have been repairing installing furnaces, heating systems and heat pumps in Smyrna and the Atlanta area since 1966.  We offer 24 hour emergency service for unexpected heating system break downs.  We can provide expert maintenance and repair on your current heating system or help you select a new, high-efficiency heating system from our wide range of furnaces.
Kabran Air Conditioning & Heating has been providing homeowners throughout Cocoa Beach FL, Satellite Beach FL, Cape Canaveral FL, Rockledge FL, Melbourne FL, Merritt Island FL, Viera FL, Indian Harbour Beach FL with reliable residential heating and air conditioning services since 1984. Whether you need installation, maintenance, or repair, our team of heating and cooling specialists has the experience and knowledge to leave you with optimum comfort every time. We’re dedicated to your satisfaction and the health and safety of your indoor environment. We offer trusted Carrier brand heating and air conditioning products, and an expertise that goes above and beyond for all our HVAC services. Contact our trustworthy team today and get the heating and air conditioning service you deserve!
The belt should slip right into place. If it seems to be too tight or difficult to set in place, it may be necessary to adjust the motor mount to provide more slack. Then you can re-tighten the tension once the belt is in place. Check the manufacturer’s specifications for proper tension—in most cases, the belt should deflect about an inch when you press down on it.

The 2nd-century Chinese mechanical engineer and inventor Ding Huan of the Han Dynasty invented a rotary fan for air conditioning, with seven wheels 3 m (10 ft) in diameter and manually powered by prisoners of the time.[6] In 747, Emperor Xuanzong (r. 712–762) of the Tang Dynasty (618–907) had the Cool Hall (Liang Dian 涼殿) built in the imperial palace, which the Tang Yulin describes as having water-powered fan wheels for air conditioning as well as rising jet streams of water from fountains. During the subsequent Song Dynasty (960–1279), written sources mentioned the air conditioning rotary fan as even more widely used.[7]
Your furnace's flame sensor is essentially a safety mechanism. As a thin metallic rod in front of the flame inside the unit, it's sole purpose is to confirm that your gas valves only open when a flame actually exists to burn that gas. When the flame sensor stop working, on the other hand, gas leaks can occur. To repair your furnace's flame sensor, expect to spend between $80 and $250. Even a full replacement of this part typically does not go above that range.
Ground source, or geothermal, heat pumps are similar to ordinary heat pumps, but instead of transferring heat to or from outside air, they rely on the stable, even temperature of the earth to provide heating and air conditioning. Many regions experience seasonal temperature extremes, which would require large-capacity heating and cooling equipment to heat or cool buildings. For example, a conventional heat pump system used to heat a building in Montana's −70 °F (−57 °C) low temperature or cool a building in the highest temperature ever recorded in the US—134 °F (57 °C) in Death Valley, California, in 1913 would require a large amount of energy due to the extreme difference between inside and outside air temperatures. A few feet below the earth's surface, however, the ground remains at a relatively constant temperature. Utilizing this large source of relatively moderate temperature earth, a heating or cooling system's capacity can often be significantly reduced. Although ground temperatures vary according to latitude, at 6 feet (1.8 m) underground, temperatures generally only range from 45 to 75 °F (7 to 24 °C).
Within the construction sector, it is the job of the building services engineer to design and oversee the installation and maintenance of the essential services such as gas, electricity, water, heating and lighting, as well as many others. These all help to make buildings comfortable and healthy places to live and work in. Building Services is part of a sector that has over 51,000 businesses and employs represents 2%-3% of the GDP.

American design standards are legislated in the Uniform Mechanical Code or International Mechanical Code. In certain states, counties, or cities, either of these codes may be adopted and amended via various legislative processes. These codes are updated and published by the International Association of Plumbing and Mechanical Officials (IAPMO) or the International Code Council (ICC) respectively, on a 3-year code development cycle. Typically, local building permit departments are charged with enforcement of these standards on private and certain public properties.

×