Turn off the gas supply valve, typically located by your gas meter on the gas inlet pipe. Turn off the gas by rotating the valve one quarter turn with an adjustable wrench. When the gas is off,  the valve’s oblong stem points perpendicular to the inlet pipe. Then call your gas utility or the fire department from a remote location. Do not return to your home until you know it is safe.
Evaporative coolers, sometimes called "swamp coolers", do not have a compressor or condenser. Liquid water is evaporated on the cooling fins, releasing the vapor into the cooled area. Evaporating water absorbs a significant amount of heat, the latent heat of vaporisation, cooling the air. Humans and animals use the same mechanism to cool themselves by sweating.
The belt should slip right into place. If it seems to be too tight or difficult to set in place, it may be necessary to adjust the motor mount to provide more slack. Then you can re-tighten the tension once the belt is in place. Check the manufacturer’s specifications for proper tension—in most cases, the belt should deflect about an inch when you press down on it.
We want to compliment your fine sales and installation team. They are outstanding. Carlos, your sales rep., was highly informative. We reviewed our needs and we ultimately chose the Trane XV-18 variable speed system. Carlos did not try to up sell us with things that we did not need but he did help us choose the correct upgraded filter and UV light that we wanted. We told Carlos that our research indicated that the quality of the installation of the unit was at least as important as the unit itself, and Carlos agreed. Carlos pointed out that new proper sized duct work and copper wiring would be required for a correct installation, and that we needed to add two more returns. We asked if more returns were needed and Carlos said that would not be cost effective. That was great to hear. Carlos assured us that the installation team of Willie and Gary, both lead installers, would be used. They were both superb. They came on time and worked for 12 and 1/2 hours. It was a 93 degree day so the heat in the attic was intense. We kept telling them to take a break but they continued to work up there in what must have been 130+ temperatures. They were amazing! They were neat and cleaned up any mess they made. They patiently answered all of our many questions and gave us helpful tips. They were truly professional in all respects. We also note that Stacy, Angie and Karen of your office staff were each courteous, accommodating and efficient. They helped things to go smoothly. Carlos, Gary, Stacy, Angie, Willie and Karen are each great assets to your company. We would be comfortable recommending that team of people to anyone! Ken and Kathy Luban

Strongsville Heating & Air Conditioning simplifies the challenges of keeping a perfectly comfortable home. We provide convenience, cost-savings, and reliability using top of the line products, premium materials, highly skilled technicians and exceptional customer service. Whether you need a new heating/cooling installation, replacement, retrofit, routine maintenance, trustworthy repair or air quality options, count on our team of NATE-certified technicians to eliminate stress and maximize comfort. We protect your busy schedule with flexible appointments, prompt arrival and mess free completion. Strongsville Heating & Air Conditioning is always available to you for Emergency Service, 24 hours a day, 365 days a year across Strongsville & Surrounding Areas.
An electric furnace provides warmth by moving air over and through a series of coils. Ductwork and vents then distribute that air to the individual rooms in your home. Repair costs will depend on both the brand and the exact nature of the problem, but tend to be lower than some of the options above. That's because the units are small, and issues tend to be contained within the heating elements themselves. Expect to spend less than $300 on your electric furnace repair, depending on the exact problem.
Natural ventilation is the ventilation of a building with outside air without using fans or other mechanical systems. It can be via operable windows, louvers, or trickle vents when spaces are small and the architecture permits. In more complex schemes, warm air is allowed to rise and flow out high building openings to the outside (stack effect), causing cool outside air to be drawn into low building openings. Natural ventilation schemes can use very little energy, but care must be taken to ensure comfort. In warm or humid climates, maintaining thermal comfort solely via natural ventilation might not be possible. Air conditioning systems are used, either as backups or supplements. Air-side economizers also use outside air to condition spaces, but do so using fans, ducts, dampers, and control systems to introduce and distribute cool outdoor air when appropriate.
The Chartered Institution of Building Services Engineers is a body that covers the essential Service (systems architecture) that allow buildings to operate. It includes the electrotechnical, heating, ventilating, air conditioning, refrigeration and plumbing industries. To train as a building services engineer, the academic requirements are GCSEs (A-C) / Standard Grades (1-3) in Maths and Science, which are important in measurements, planning and theory. Employers will often want a degree in a branch of engineering, such as building environment engineering, electrical engineering or mechanical engineering. To become a full member of CIBSE, and so also to be registered by the Engineering Council UK as a chartered engineer, engineers must also attain an Honours Degree and a master's degree in a relevant engineering subject.
If you hear clicking that is followed by a hum or buzz, you’re probably hearing the fan motor attempting to start without the boost it needs from the capacitor. You can almost always conclude that the capacitor has failed. Sometimes you can get the compressor fan spinning (clockwise) by pushing it with a thin stick or long screwdriver poked through the grille. But the chances are good that this might work for one cycle, but the capacitor will fail next time the AC goes on. It’s best to replace the capacitor.
Before opening the electrical cover on the A/C unit, be sure to shut off all power to the compressor unit and the indoor furnace or air handler, and verify that it is off. Note that this may mean shutting off a circuit breaker that serves the furnace and air handler, and then, near the compressor, pulling out the disconnect block (or shutting off the 220-volt power) to the outdoor compressor.
×